If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-21730 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.8,"lon":-80.73,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Elkrun Township | |
Operator Name: CHESAPEAKE EXPLORATION LLC | |
Well Pad ID: US-OH-000467 | |
Farm/Lease Name: GRUBBS 6-11-2 | |
License Status: Plugged Back | |
License Date: 2012-04-26 | |
Spud Date: 2012-06-09 | |
Spud Drilling Contractor: NOMAC DRILLING CORP | |
Final Drill Date: 2012-06-27 | |
Well Total Depth: 8580.00 ft | |
Configuration: Vertical | |
Latitude: 40.800000 | |
Longitude: -80.730000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-04-26 | Proposed Formations:TRENTON-BLACK RIVER, Issued Date:4/26/2012, Expired Date:4/26/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Reached Total Depth | 2012-06-27 | |
Completion Report Received | 2012-07-26 | |
End of Confidential Data | 2013-06-27 | |
Construction Permit Expires | 2014-04-26 | |
Record Last Modified | 2016-03-18 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2014-09-10 | 8512 | 10899 | 224 |
8512 | 10899 | 224 | |
8512 | 10899 | 224 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 07/19/2012 | 07/19/2012 | 8095.00 | 1,824,900.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 000584-08-7 | |||||||
Anti-Bacterial Agent | ||||||||
100.00 | ||||||||
000111-76-2 | ||||||||
100 Mesh Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 1.37 | |||
000107-21-1 | ||||||||
007727-54-0 | ||||||||
Ammonium Persulfate | ||||||||
20.00 | ||||||||
MC MX 2-2822 | ||||||||
1.00 | ||||||||
13.00 | ||||||||
Dioxide) | ||||||||
pH Adjusting Agent | ||||||||
Multi-Chem | ||||||||
CI-150 (Corrosion Inhibitor) | FTS International | Corrosion Inhibitor | Proprietary Aromatic Aldehyde | 10.00 | 0.00015000 | |||
Proprietary Quaternary Ammonium Compound | 10.00 | 0.00015000 | ||||||
N,N-Dimethylformamide | 68-12-2 | 10.00 | 0.00015000 | |||||
Isopropanol | 67-63-0 | 60.00 | 0.00088000 | |||||
Proprietary Organic Amine Resin Salt | 30.00 | 0.00044000 | ||||||
48.00 | ||||||||
10.1 - 15 HCL | FTS International | Acid | Water | 7732-18-5 | 85.00 | 0.76 | ||
Hydrochloric acid | 7647-01-0 | 15.00 | 0.13 | |||||
0.02549 | ||||||||
0.01179 | ||||||||
Proprietary Cured Acrylic Resin
Petroleum Distillate Hydrotreated Light Ethylene Glycol |
||||||||
0.00000 | ||||||||
APB-01 Ammonium Persulfate Breaker | ||||||||
10.00 | ||||||||
0.00161 | ||||||||
Additional Ingredients Not Listed on MSDS | ||||||||
12.00 | ||||||||
4.00 | ||||||||
068439-51-0 | ||||||||
Glutaraldehyde (Pentanediol) Quaternary
Ammonium Compound Ethanol |
||||||||
001310-58-3 | ||||||||
Isopropanol | ||||||||
0.00020 | ||||||||
25.00 | ||||||||
FRW-200W | ||||||||
15.00 | ||||||||
0.00083 | ||||||||
0.00324 | ||||||||
FTS INTERNATIONAL | ||||||||
0.00637 | ||||||||
0.00648 | ||||||||
Scale Inhibitor | ||||||||
KCLS4 | ||||||||
Cross Linker | ||||||||
Surfactant | ||||||||
BXL02 Borate XL B10 (HIGH PH | ||||||||
Methanol | ||||||||
30.00 | ||||||||
0.00225 | ||||||||
010555-76-7 | ||||||||
Friction Reducer | ||||||||
0.00250 | ||||||||
Ottawa Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 11.80 | |||
2.00 | ||||||||
Proprietary Sulfonate | ||||||||
APB01 (AMMONIUM PERSUFATE BREAKER),
B10 (HIGH PH BUFFER), BXL02 Borate XL, CI-150, FE-100L, FRW-200W, KCLS-4, LTB-01, NE 100 |
FTS International | Breaker, Clay Stabilizer, Corrosion Inhibitor, Cross Linker, Friction Reducer, Iron Control Agent, Non-Emulsifier, pH Adjusting Agent | Proprietary Breaker (APB01) Additive | |||||
Proprietary Friction Reducer Additive
(FRW-200 and FRW-200W) |
||||||||
Proprietary Breaker Additive (LTB-1) | ||||||||
Proprietary Corrosion Inhibitor Additive (CI-150) | ||||||||
Water | 7732-18-5 | |||||||
Proprietary Clay Stabilizer Additive (KCLS-4) | ||||||||
5.00 | ||||||||
Monobutyl Ether) | ||||||||
No Hazardous Components | ||||||||
TRADE SECRET | ||||||||
0.00258 | ||||||||
LT Encapsulated AP Breaker (LTB01) | ||||||||
Non-Emulsifier | ||||||||
0.00183 | ||||||||
000067-63-0 | ||||||||
FE 100L (Iron Chelator) | FTS International | Iron Control Agent | Citric acid | 77-92-9 | 55.00 | 0.00405000 | ||
000067-56-1 | ||||||||
Dodecylbenzenesulfonic Acid Sodium
Metaborate Tetrahydrate Boric Acid |
||||||||
Crystalline Silica (Quartz) | ||||||||
BUFFER) | ||||||||
MC B-8642 (WS), MC MX 2-2822 | Multi-Chem Group | Anti-Bacterial Agent, Scale Inhibitor | Methanol | 67-56-1 | ||||
Water | 7732-18-5 | |||||||
Non-MSDS Components Not Provided by Supplier | ||||||||
TRADE SECRET TRADE SECRET | ||||||||
Clay Stabilizer | ||||||||
000064-17-5 | ||||||||
0.01370 | ||||||||
INTERNATI ONAL | ||||||||
014808-60-7 | ||||||||
027176-87-0 | ||||||||
068424-85-1 | ||||||||
MC B-8642 (WS) | ||||||||
FTS | ||||||||
0.00196 | ||||||||
0.00281 | ||||||||
0.00468 | ||||||||
60.00 | ||||||||
2-Butoxyethanol (Ethylene Glycol | ||||||||
000111-30-8 | ||||||||
HVG01 (TURQUOISE-1 BULK) | FTS International | Gelling Agent | Distillates, petroleum, hydrotreated light | 64742-47-8 | 55.00 | 0.04 | ||
Guar gum | 9000-30-0 | 50.00 | 0.04 | |||||
Quartz | 14808-60-7 | 2.00 | 0.00170000 | |||||
064742-47-8 | ||||||||
0.00170 | ||||||||
NONE | ||||||||
Proprietary Ethoxylated Alcohol Blend | ||||||||
0.00108 | ||||||||
010043-35-3 | ||||||||
Breaker | ||||||||
Fresh Water | Carrier/Base Fluid | 72.76 | ||||||
Recycled Produced Water | Carrier/Base Fluid | 12.81 | ||||||
Potassium Hydroxide Potassium Carbonate Potassium Hydroxide |
For data sources see[4]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 0 |
2014 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 0 |
2015 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 0 |
2016 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 0 |
2017 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 122 |
2018 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 90 |
2019 | CHESAPEAKE EXPLORATION LLC | Brine | 0 | 59 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1135908105 | 2019-5-29 0:00: | TI | No Violations | 2.10 |
-1140585904 | 2020-4-28 0:00: | TI | No Violations | 1.00 |
-1943983827 | 2019-12-19 0:00 | TI | No Violations | 1.00 |
-205284574 | 2018-3-8 0:00:0 | PW | No Violations | 0.60 |
-311454858 | 2015-4-7 0:00:0 | PW | No Violations | |
-343332951 | 2016-4-4 0:00:0 | PW | No Violations | |
-382059660 | 2020-4-6 0:00:0 | TI | No Violations | 1.00 |
-458046771 | 2017-8-3 0:00:0 | PW | No Violations | 1.00 |
0205284574 | 2018-03-08 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1730. ODNR-DOGRM Northeast District Supervisor Stephen Ochs was present during the inspection. The well had a valid permit for temporary inactive status. Correct identification was present at the entrance. The road and well pad remained in good repair. The perimeter security fence remained in good repair and locked. The topsoil stock pile remained stable. The cut and fill slopes remained stable with no evidence of mass wasting. The earthen berm perimeter remained stable. The standpipe drains on the North and South side were shut. Fresh water was ponding on the pad. Correct identification was present at the well head. Jersey barriers were present to prevent a collision. Grates remained over the cellar to prevent falls. The cellar contained freshwater. No leaks were observed. Gauges to measure annular casing pressure were in the open position and labeled. The 9.625 annulus indicated 0 psi. The 5.5 annulus indicated 500 psi. The 5.5 production casing wing valve gauge indicated 600 psi. The production tree cap gauge indicated 0 psi. No production equipment was on location. No violations were observed during this inspection. |
0311454858 | 2015-04-07 | Production Wells | No Violations
-established ground cover. The soil stockpile is well stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. I emailed Steve Ault of Chesapeake on 4/24/2015 about the identification signs. He replied on 4/27/2015 that they had located the wellhead identification signs and they would be installed within the week. I recommend temporary inactive status be granted. | |
0343332951 | 2016-04-04 | Production Wells | No Violations | I was on location for a status check. My inspection found the access road gate locked and the
access road in good repair. The pad is fenced and all man doors were locked. An identification sign is posted at the access road entrance and well. The #6H is not in production. The well is equipped with a christmas tree valve assembly. The equipment on the pad consists of the following: Site fenced and man doors locked |
0349105388 | 2016-11-29 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1730-01. The well is currently in temporary inactive status. Correct well identification remains present at the entrance and well head. Lease access and the well pad facilities remain in good repair. No other equipment is on the pad. The Owner raised and identified the 9.625 intermediate annular casing pressure gauge and the 5.5 production annular casing pressure gauge. The intermediate annular casing gauge indicated 0 psi. The production casing annular gauge indicated 640 psi. Maximum allowable annular surface pressure (MAASP) at the surface per ORC 1501:9-1-08 (N) (2) is 390 psi. The production casing pressure gauge indicated 400 psi. I will be contacting Chesapeake Regulatory Affairs Advisor Jody Jones concerning the observed pressure on the production casing annulus in order to facilitate further investigation. |
0458046771 | 2017-08-03 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1730-01. The lease road and pad remained in good repair. A locked chain link perimeter fence was present around the pad. Correct identification was present at the well head. The well cellar contained fresh water at free board and was covered by a steel grate. No leaks were detected. The annular pressure gauges were identified. The 9.625 pressure gauge indicated 0 psi. The 5.5 annular pressure gauge indicated 710 psi. No pressure relief device was present on the 9.625 casing. The 5.5 production casing was equipped with a Christmas tree valve assembly. Valves were closed. The 5.5 production casing gauge indicated 400 psi. The tubing pressure gauge indicated 0 psi. No other equipment was present on the pad. I will contact Chesapeake regulatory manager Jody Jones concerning the excessive annular pressure. |
0988798440 | 2016-06-16 | Production Wells | No Violations | My purpose for inspection was to conduct a second year temporary inactive well status inspection. The inspection was conducted with ODNR DOGRM Northeast Regional Supervisor Thomas Hill and Northeast District Supervisor Richard Anderson. There is one well on the pad.
The sign board posted at the lease entrance displayed signs with the well name, address, permit number and emergency contact information. The lease road was graveled and in good repair with a locked gate off of Miller Road. Erosion and sedimentation controls were in place and ground cover was well established along the road. I walked the entire location and found the well pad constructed with an earthen berm perimeter in good repair, being stabilized with well-established vegetation. Erosion and sedimentation controls are in place and functioning. The well pad was found to be enclosed by a chain link fence with barbed wire at the top. The primary entrance and escape doors were all found to be locked. The surface of the well pad consists of gravel and is in good repair. The well pad was constructed with a site drain and the standpipe was shut. Soil stockpile is stabilized with well-established vegetation. The Grubbs 6H was constructed with 90 of 20 conductor, 615 of 13 3/8 surface casing, 1289 of 9 5/8 intermediate casing and 11000 of 5 1/2 production casing. Drilling was completed 7/2/2012. The well was stimulated on 7/19/2012 and completed with 7796 of 2 7/8 tubing. The well head was constructed with a Christmas tree valve assembly and found to be protected by a perimeter of steel cattle gates further protected by concrete Jersey barriers. Proper signage was displayed. A cellar grate was in place to prevent falls. The cellar contained water that was near freeboard. No leaking gas was observed in the cellar. The mousehole was cemented. Gate valves are chained and locked. No other production equipment is on the pad. I recommend that the pressures associated with the respective |
1344444219 | 2012-07-30 | Drill / Deepen / Reopen | Violations Noted | On 7/30/2012, I was contacted by the ODNR Uniontown Office that Ray Daniels was driving south on State Route 11 when he saw a flame coming from what he thought was a drilling rig. When I arrived in the area of Route 517 and Davnor Road, I saw a flame coming from a Chesapeake Location ( Grubb 6-11-2 6 ). I spoke to a person working for Chesapeake he said that they were doing a flow test and that they would be flaring the gas until 8/8/2012. The ODNR Uniontown Office was not notified. |
1350499252 | 2012-10-17 | Drill / Deepen / Reopen | No Violations | I inspecteed the above location, there has been no flaring of gas. Required action has been completed. |
1363878078 | 2012-07-30 | Drill / Deepen / Reopen | No Violations | FOLLOW UP TO NOV # 1344444219 On 7/30/2012, I was contacted by the ODNR Uniontown Office that Ray Daniels was driving south on State Route 11 when he saw a flame coming from what he thought was a drilling rig. When I arrived in the area of Route 517 and Davnor Road, I saw a flame coming from a Chesapeake Location ( Grubb 6-11-2 6 ). I spoke to a person working for Chesapeake he said that they were doing a flow test and that they would be flaring the gas until 8/8/2012. The ODNR Uniontown Office was not notified. |
1369378253 | 2020-3-27 0:00: | TI | No Violations | 1.00 |
1585228668 | 2020-3-26 0:00: | PL | No Violations | 1.00 |
1588104024 | 2018-11-20 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-1730. Correct identification was present at the entrance. The road and well pad remained in good repair. The perimeter security fence remained in good repair and locked. The perimeter slopes remained stable with well-established vegetation. The French drain stand pipes remained open. Correct identification was present at the well head. Jersey barriers were present to prevent a collision. Grates remained over the cellar to prevent falls. The cellar contained freshwater. No leaks were observed. Gauges to measure annular casing pressure were present and labeled. The 9.625 annulus indicated 0 psi. The 5.5 annulus indicated 540 psi. The 5.5 production casing wing valve gauge indicated 0 psi. The production tree cap gauge indicated 0 psi. All valves were closed, chained and locked. No production equipment was on location. No violations were observed during this inspection. |
1588869360 | 2020-5-7 0:00:0 | TI | No Violations | 1.00 |
1691736102 | 2019-11-25 0:00 | TI | No Violations | 1.00 |
349105388 | 2016-11-29 0:00 | PW | No Violations | |
988798440 | 2016-6-16 0:00: | PW | No Violations | 2.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1344444219 | US-OH-109959 | 2012-08-09 | Unlawful venting or flaring of gas |
For data sources see[7]