34-029-21725

Well Details

Well ID: 34-029-21725
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: EAP OHIO LLC
Well Pad ID: US-OH-000896
Farm/Lease Name: MORRIS 28-11-2
License Status: Temporary Inactive Status 4th Year
License Date: 2017-05-10
Spud Date: 2012-05-27
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2012-06-09
Well Total Depth: 13284.00 ft
Configuration: Horizontal
Latitude: 40.750000
Longitude: -80.700000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-03-19 Proposed Formations:POINT PLEASANT, Issued Date:3/19/2012, Expired Date:3/19/2014 12:00:00 PM, Drilling unit acres:101.6, Proposed Well Type:OG, Proposed Well Class:EDPW
APP 2012-06-05 Proposed Formations:POINT PLEASANT, Issued Date:6/5/2012, Expired Date:6/5/2014 12:00:00 PM, Drilling unit acres:138.3, Proposed Well Type:OG, Proposed Well Class:EDPW
Reached Total Depth 2012-06-09 TEMPORARY INACTIVE CHECKLIST REC'D FROM CO ON 05/02/2016/12/01/2016--REC'D TA2 CHECKLIST
Correction to Well 2013-05-17 CORRECTION TO TARGET INFORMATION (FOOTAGE & X,Y COORDINATES) FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 123.62 ACRES.
Correction to Well 2015-01-30 CHANGE IN TARGET INFORMATION (FOOTAGES AND COORDINATES) FROM NEW SURVEY PLAT.
APP 2015-06-02 Proposed Formations:POINT PLEASANT, Issued Date:6/2/2015, Expired Date:6/1/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:TI
APP 2017-05-10 Proposed Formations:, Issued Date:5/10/2017, Expired Date:5/10/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:TI
Construction Permit Expires 2018-05-10 TEMPORARY INACTIVE CHECKLIST REC'D FROM CO ON 05/02/2016/12/01/2016--REC'D TA2 CHECKLIST
Record Last Modified 2019-05-15 TEMPORARY INACTIVE CHECKLIST REC'D FROM CO ON 05/02/2016/12/01/2016--REC'D TA2 CHECKLIST

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-09-10 8626 13100 256
8626 13100 256
8626 13100 256

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 07/15/2012 07/15/2012 8211.00 2,958,186.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HVG01 (TURQUOISE-1 BULK) FTS International Gelling Agent Guar gum 9000-30-0 50.00 0.05
Quartz 14808-60-7 2.00 0.00207000
Distillates, petroleum, hydrotreated light 64742-47-8 55.00 0.05
0.01222
Additional Ingredients Not Listed on MSDS
26.00
Surfactant
5.00
10.00
25.00
Proprietary Cured Acrylic Resin
NALCO
0.00830
INTERNATI ONAL
Borate XL Instant XL (BXL02)
0.00498
0.00207
068439-51-0
12.00
N/A
000064-17-5
010043-35-3
48.00
001310-58-3
000111-30-8
Sodium Metaborate Tetrahydrate
0.00398
APB01 (AMMONIUM PERSUFATE BREAKER),

B10 (HIGH PH BUFFER), BXL02 Borate XL, CI-150, FE-100L, FRW-200, KCLS-4, LTB-01

FTS International Breaker, Clay Stabilizer, Corrosion Inhibitor, Cross Linker, Friction Reducer, Iron Control Agent, pH Adjusting Agent Proprietary Breaker Additive (LTB-1)
Proprietary Breaker (APB01) Additive
Proprietary Corrosion Inhibitor Additive (CI-150)
Proprietary Clay Stabilizer Additive (KCLS-4)
Water 7732-18-5
Proprietary Friction Reducer Additive

(FRW-200 and FRW-200W)

EC6110A, EC6629A Nalco Anti-Bacterial Agent, Scale Inhibitor Water 7732-18-5
Proprietary Quaternary Ammonium Salt
Proprietary Acrylate Polymer
Methanol 67-56-1
KCLS4
0.00277
10.1 - 15 HCL FTS International Acid Water 7732-18-5 85.00 0.80
Hydrochloric acid 7647-01-0 15.00 0.14
LT Encapsulated AP Breaker (LTB01)
Ammonium Persulfate
pH Adjusting Agent
Dioxide)
FTS INTERNATIONAL
Quaternary Ammonium Compounds
Glutaraldehyde
B10 (HIGH PH BUFFER)
100 Mesh Sand Proppant Quartz 14808-60-7 100.00 1.31
064742-47-8
20.00
60.00
FRW-200
Boric Acid
15.00
000584-08-7
FE 100L (Iron Chelator) FTS International Iron Control Agent Citric acid 77-92-9 55.00 0.00412000
Scale Inhibitor
Fresh Water Carrier/Base Fluid 70.48
Crystalline Silica (Quartz)
CI-150 (Corrosion Inhibitor) FTS International Corrosion Inhibitor Proprietary Organic Amine Resin Salt 30.00 0.00046000
Isopropanol 67-63-0 60.00 0.00093000
Proprietary Quaternary Ammonium Compound 10.00 0.00015000
Proprietary Aromatic Aldehyde 10.00 0.00015000
N,N-Dimethylformamide 68-12-2 10.00 0.00015000
0.01063
Anti-Bacterial Agent
0.01177
No Hazardous Components
100.00
Cross Linker
Recycled Produced Water Carrier/Base Fluid 13.00
Ottawa Sand Proppant Quartz 14808-60-7 100.00 13.87
0.00204
007727-54-0
Potassium Hydroxide Potassium Carbonate Potassium Hydroxide
0.00664
0.04253
FTS
Friction Reducer
0.00203
010555-76-7
TRADE SECRET
EC6110A
Clay Stabilizer
0.00000
0.00102
Distillates, petroleum, hydrotreated light
APB-01 Ammonium Persulfate Breaker
014808-60-7
NONE
Ethanol
2.00
EC6629A
Breaker

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2012-07-15 H2O 15 9656 Bbl 571037 Frac Tech Services STAGE 1/8

32 SHOTS STAGES 2-7 SEE IMAGES

2012-07-17 H2O 15 8080 Bbl 572236 Frac Tech Services STAGE 8/8

32 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC 0 0 0
2014 CHESAPEAKE EXPLORATION LLC 0 0 0
2015 CHESAPEAKE EXPLORATION LLC 0 0 0
2016 CHESAPEAKE EXPLORATION LLC 0 0 0
2017 CHESAPEAKE EXPLORATION LLC 0 0 61
2018 CHESAPEAKE EXPLORATION LLC 0 0 61
2019 CHESAPEAKE EXPLORATION LLC 0 0 59

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC Brine 0 0
2014 CHESAPEAKE EXPLORATION LLC Brine 0 0
2015 CHESAPEAKE EXPLORATION LLC Brine 0 0
2016 CHESAPEAKE EXPLORATION LLC Brine 0 0
2017 CHESAPEAKE EXPLORATION LLC Brine 0 61
2018 CHESAPEAKE EXPLORATION LLC Brine 0 61
2019 CHESAPEAKE EXPLORATION LLC Brine 0 59

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1190674796 2015-4-23 0:00: PW No Violations
-1663606763 2018-11-20 0:00 PW No Violations 0.50
-1846422589 2020-3-26 0:00: PL No Violations 1.00
0728988608 2016-03-04 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the access road in good repair. The pad is fenced and all man doors were locked. An identification sign is posted at the access road entrance and well. The #3H is not in production. The well is equipped with a christmas tree valve assembly.

The equipment on the pad consists of the following:

Site fenced and man doors locked

1096881046 2013-07-23 Preliminary Restoration No Violations I reviewed the site to assess the completion of preliminary restoration. There is a sign board at the access road entry featuring the well name, permit number and emergency contact information. The access road has a padlocked gate near Darner Road. The access road is in good repair. Drainage and erosion controls were in place and appear to be functioning. Ground cover was well established along the access road. I found the drilling/production pad to be enclosed entirely with a chain link fence with barbed wire at the top, and with a padlocked gate. The pad has a crushed limestone surface, and is in good repair. The pad does have considerable ponded water along the perimeter. The fence is in good repair. Outside the fence, there is an earthen berm. I walked the exterior perimeter and noted that the berm is in good repair and ground cover is well established. Most of the area of disturbance has good ground cover. The soil stockpile is well stabilized with vegetation. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. The well has been fracked, and has a Christmas tree valve assembly. There are concrete barriers surrounding the wellhead and cellar to prevent vehicle impacts. There are grates over the cellar to prevent falls. There is no production equipment at the site. The cellar is full of water to the top. Preliminary restoration approval will not be finalized pending installation of production equipment and re-inspection.
1190674796 2015-04-23 Production Wells No Violations

-established ground cover. The soil stockpile is well stabilized with vegetation. Drainage and erosion controls at the pad are in place and functioning. I emailed Steve Ault of Chesapeake on 4/24/2015 about the identification signs. He replied on 4/27/2015 that they had located the wellhead identification signs and they would be installed within the week. I recommend temporary inactive status be granted.

1406572091 2014-05-20 Production Wells No Violations I stopped by the site to check on the status of well completion and restoration. The well has been hydraulically fractured, but no production equipment is on site. I walked the entire site, and found the location to be in good condition. All erosion and sedimentation controls, and drainage controls appear to be functioning. Ground cover is well established along the access road and around the drilling pad. No areas of erosion are present. Preliminary restoration approval will not be finalized pending installation of production equipment. All valves are chained and locked.
1466690579 2016-06-16 Production Wells No Violations My purpose for inspection was to conduct a second year temporary inactive well status inspection. The inspection was conducted with ODNR DOGRM Northeast Regional Supervisor Thomas Hill and Northeast District Supervisor Richard Anderson. There is one well on the pad.

The sign board posted at the lease entrance displayed signs with the well name, address, permit number and emergency contact information. The lease road was graveled and in good repair with a locked gate at Darner Road. Erosion and sedimentation controls were in place and ground cover was well established along the road. I walked the entire location and found the well pad constructed with an earthen berm perimeter in good repair, being stabilized with well-established vegetation. Erosion and sedimentation controls are in place and functioning. The well pad was found to be enclosed by a chain link fence with barbed wire at the top. The primary entrance and escape doors were all found to be locked. A section of fence on the Northwest side was found to be damaged and unable to prevent unauthorized access to the site. The surface of the well pad consists of gravel and is in good repair. The well pad was not constructed with a site drain and several areas on the pad contained ponding water. Soil stockpile is stabilized with well-established vegetation. The Morris 3H was constructed with 100 of 20 conductor, 664 of 13 3/8 surface casing, 1825 of 9 5/8 intermediate casing and 13268 of 5 1/2 production casing. Drilling was completed 6/9/2012. The well was stimulated on 7/15/2012 and completed with 7630 of 2 7/8 tubing. The well head was found to be protected by a perimeter of steel cattle gates that were further protected by concrete Jersey barriers. Proper signage was displayed. A cellar grate was in place to prevent falls. The cellar contained water and was near freeboard. A slight sheen was observed on the water surface. No leaking gas was observed in the cellar. The mousehole was ce

1479148243 2016-11-14 Production Wells No Violations The purpose for my inspection was to follow up on action necessary from a previous inspection. The Owner has repaired the perimeter security fence to prevent unauthorized entry. The surface and intermediate casing pressure gauges have been raised above ground level and identified. The 13 3/8 surface casing pressure gauge indicated 0 psi. The intermediate casing pressure gauge indicated 330 psi. This pressure remains below the maximum allowable pressure of 552 psi. No further action is necessary.
1576771326 2019-12-19 0:00 TI No Violations 2.00
1663606763 2018-11-20 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1725. Correct identification was present at the entrance. The road and well pad remained in good repair. The perimeter security fence remained in good repair and locked. The perimeter berm and slopes remained stable with well-established vegetation. The French drain stand pipes remained closed with standing meteoric water ponding on the East side of the pad.. Correct identification was present at the well head. Jersey barriers were present to prevent a collision. Grates remained over the cellar to prevent falls. The cellar contained freshwater. No leaks were observed. Gauges to measure annular casing pressure were present and labeled. The 9.625 annulus indicated 0 psi. The 5.5 annulus indicated 560 psi. The 5.5 production casing wing valve gauge indicated 0 psi. The production tree cap gauge indicated 0 psi. All valves were chained, closed and locked. No production equipment was on location. No violations were observed during this inspection.
1695798149 2019-5-29 0:00: TI No Violations 0.30
1741986314 2016-04-04 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the

access road in good repair. The pad is fenced and all man doors were locked. An identification sign is posted at the access road entrance and well. The #3H is not in production. The well is equipped with a christmas tree valve assembly. The equipment on the pad consists of the following:

Site fenced and man doors locked

1966604888 2017-07-19 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #1725. Correct signage remained posted at the entrance. The access road remained in good repair. No evidence of accelerated erosion or sedimentation was present along the road. The pad was enclosed by a locked chain-link fence perimeter. The fence remained in good repair with no signs of vandalism. An earthen berm perimeter was present outside of the fencing. I walked the perimeter of the pad and found no evidence of erosion or sedimentation. The topsoil stockpile remained stable. The pad was composed of crushed gravel that remained in good repair. A jersey barrier perimeter was present around the well head. Correct signage was present on the well head. Annular pressure gauges were identified. The 13.375 annular gauge identified 0 psi. The 9.625 annular gauge identified 400 psi. The 5.5 production casing gauge identified 100 psi. No violations were observed during this inspection.
663261292 2019-11-25 0:00 TI No Violations 1.00
728988608 2016-3-4 0:00:0 PW No Violations 0.50
827970918 2020-4-28 0:00: TI No Violations 1.00