34-029-21705

Well Details

Well ID: 34-029-21705
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Franklin Township
Operator Name: CHESAPEAKE EXPLORATION LLC
Well Pad ID: US-OH-000425
Farm/Lease Name: ALBANESO 24-14-4
License Status: Plugged Back
License Date: 2012-01-24
Spud Date: 2012-05-05
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2012-05-15
Well Total Depth: 8295.00 ft
Configuration: Vertical
Latitude: 40.680000
Longitude: -80.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2012-01-24 Proposed Formations:TRENTON - BLACK RIVER, Issued Date:1/24/2012, Expired Date:1/23/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Reached Total Depth 2012-05-15
Completion Report Received 2012-06-20
Construction Permit Expires 2014-01-23
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-03-19 8619 13580 315
8619 13580 315
8619 13580 315

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/18/2012 06/18/2012 8102.00 3,604,566.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 APB-01 Ammonium Persulfate Breaker FTS International Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.00184000
Additional Ingredients Not Listed on MSDS
APB01 (AMMONIUM PERSUFATE BREAKER),

B10 (HIGH PH BUFFER), BXL02 Borate XL, CI-150, FE-100L, FRW-200W, LTB-01

FTS International Breaker, Corrosion Inhibitor, Cross Linker, Friction Reducer, Iron Control Agent, pH Adjusting Agent Proprietary Corrosion Inhibitor Additive (CI-150)
Water 7732-18-5
Proprietary Friction Reducer Additive

(FRW-200 and FRW-200W)

Proprietary Breaker Additive (LTB-1)
Proprietary Breaker (APB01) Additive
B10 (HIGH PH BUFFER) FTS International pH Adjusting Agent Carbonic acid, dipotassium salt 584-08-7 48.00 0.01
Potassium hydroxide 1310-58-3 20.00 0.00625000
HVG01 (TURQUOISE-1 BULK) FTS International Gelling Agent Quartz 14808-60-7 2.00 0.00218000
Distillates, petroleum, hydrotreated light 64742-47-8 55.00 0.05
Ethoxylated propoxylated C12-14 alcohols 68439-51-0 2.00 0.00218000
Guar gum 9000-30-0 50.00 0.05
LT Encapsulated AP Breaker (LTB01) FTS International Breaker Peroxydisulfuric acid, diammonium salt 7727-54-0 100.00 0.06
Quartz 14808-60-7 25.00 0.01
EC6110A Nalco Antibacterial Agent Ethanol 64-17-5 5.00 0.00105000
Quaternary Ammonium Compounds 10.00 0.00211000
Glutaraldehyde 111-30-8 60.00 0.01
FE 100L (Iron Chelator) FTS International Iron Control Agent Citric acid 77-92-9 55.00 0.00295000
FRW-200W FTS International Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
Ethylene glycol 107-21-1 4.00 0.00229000
EC6629A Nalco Scale Inhibitor No Hazardous Components 0.00
Ottawa Sand Proppant Quartz 14808-60-7 100.00 11.51
100 Mesh Sand Proppant Quartz 14808-60-7 100.00 2.58
Recycled Produced Water Carrier/Base Fluid 9.74
EC6110A, EC6629A Nalco Anti-Bacterial Agent, Scale Inhibitor Water 7732-18-5
Proprietary Quaternary Ammonium Salt
Methanol 67-56-1
Proprietary Acrylate Polymer
CI-150 (Corrosion Inhibitor) FTS International Corrosion Inhibitor Proprietary Quaternary Ammonium Compound 10.00 0.00011000
Proprietary Organic Amine Resin Salt 30.00 0.00032000
Isopropanol 67-63-0 60.00 0.00065000
N,N-Dimethylformamide 68-12-2 10.00 0.00011000
Proprietary Aromatic Aldehyde 10.00 0.00011000
10.1 - 15 HCL FTS International Acid Hydrochloric acid 7647-01-0 15.00 0.09
Water 7732-18-5 85.00 0.53
Borate XL Instant XL (BXL02) FTS International Crosslinker Potassium hydroxide 1310-58-3 12.00 0.00210000
Sodium metaborate tetrahydrate 10555-76-7 25.00 0.00437000
Boric acid 10043-35-3 15.00 0.00262000
Fresh Water Carrier/Base Fluid 75.21

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 CHESAPEAKE EXPLORATION LLC Brine 0 0
2014 CHESAPEAKE EXPLORATION LLC Brine 6079 243
2015 CHESAPEAKE EXPLORATION LLC Brine 4081 309
2016 CHESAPEAKE EXPLORATION LLC Brine 3154 366
2017 CHESAPEAKE EXPLORATION LLC Brine 2352 365
2018 CHESAPEAKE EXPLORATION LLC Brine 1947 365
2019 CHESAPEAKE EXPLORATION LLC Brine 672 90

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1179287666 2016-3-29 0:00: PW No Violations
-1919512571 2017-8-29 0:00: PW No Violations 0.70
-792970721 2017-1-24 0:00: PW No Violations 1.50
0792970721 2017-01-24 Production Wells No Violations The purpose for my inspection was to conduct a status check well #2-1705-01-00). RBDMS indicates the operator is current with reporting production. The lease entrance is marked with a sign board containing signs reporting required well identification and emergency response information. At the time of my inspection, the local area had received a coating of snow that covered the location. The lease road is drivable. No signs of erosion were observed adjacent to the road traveling back to the pad. The soil stockpile remains stable with well-
1179287666 2016-03-29 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the

access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #8H well is in production. The well is equipped with a christmas tree valve assembly. There is a steel dike around the tank battery. The equipment on the pad consists of the following: 2 - Storage tanks 400 bbl 1 - Gas processing units (GPU) 1 - Sand separators 1 - Thermal electric generator 1 - Producing wells Site fenced and man doors locked

1418410107 2014-12-10 Preliminary Restoration No Violations

-lined and sealed secondary containment. There are concrete barriers protecting the containment from vehicles. There are e-stops outside the barriers, and the tanks are grounded, and have static dissipaters. There is a truck grounding area for trucks collecting condensate and/or produced water. There is an earthen berm, with well-established ground cover. The soil stockpile is well stabilized with vegetation. Crops, woodlands and/or underbrush are growing normally outside the area of disturbance. Drainage and erosion controls outside the pad are in place and functioning. A closed-loop, above-ground drilling pit system was used, so there are no earthen pits requiring closure. Preliminary restoration is complete and has passed inspection.

1740192481 2016-03-29 Production Wells No Violations I was on location for a status check. My inspection found the access road gate locked and the

access road is in good repair. An identification sign at the access road entrance, well, and tank battery. The pad is fenced and all man doors are locked. The #8H well is in production. The well is equipped with a christmas tree valve assembly. There is a steel dike around the tank battery. The equipment on the pad consists of the following: 2 - Storage tanks 400 bbl 1 - Gas processing units (GPU) 1 - Sand separators 1 - Thermal electric generator 1 - Producing wells Site fenced and man doors locked

1919512571 2017-08-29 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1705. The lease road and pad surface was composed of crushed gravel and remained in good repair. Correct identification was posted at the entrance and well head. A locked chain link fence remained around the pad. Ponding was present in the Southeast corner of the pad. The well head was protected by jersey barriers. The cellar contained freshwater with no sheen. Steel grate covered the cellar to prevent falls. The annular gauges were plumbed at grade and identified. Water in the cellar prevented determining if the valves were open. The 9.625 gauge indicated 0psi. The 5.5 annulus gauge identified 40 psi. The 5.5 production casing was equipped with a plunger lift assembly and was in production. The production casing gauge indicated 595 psi. The tubing pressure gauge indicated 130 psi. No leaks were observed. Production equipment on the pad consisted of one (1) sand knock out and GPU, one (1) hydrate inhibitor tank, one (1) thermal generator, one (1) meter run and two (2) 400 bbl production fluid tanks in containment. The containment was lined with impervious material and was holding water with no sheen. Valves were closed and plugged. No violations were observed during this inspection.

For data sources see[7]

References