X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-21684

Well Details

Well ID: 34-029-21684
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Butler Township
Operator Name: VANGUARD OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: KIKO-BERGER UNIT
License Status: Producing
License Date: 2008-10-21
Spud Date: 2008-10-18
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2008-10-24
Well Total Depth: 5856.00 ft
Configuration: Vertical
Latitude: 40.840000
Longitude: -80.950000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-10-21 Proposed Formations:CLINTON, Issued Date:10/21/2008, Expired Date:10/21/2009 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-10-24
Completion Report Received 2009-10-13
Construction Permit Expires 2009-10-21
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-11-13 5550 5674 219
5550 5674 219
5550 5674 219

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 110934 Gal 55000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 VANGUARD OIL & GAS LLC 2969.00 1336.00 365
2011 VANGUARD OIL & GAS LLC 2319.00 789.00 0
2012 VANGUARD OIL & GAS LLC 1691.00 431.00 366
2013 VANGUARD OIL & GAS LLC 1980.00 626.00 365
2014 VANGUARD OIL & GAS LLC 1857.00 337.00 365
2015 VANGUARD OIL & GAS LLC 1602.00 435.00 365
2016 VANGUARD OIL & GAS LLC 1818.00 201.00 365
2017 VANGUARD OIL & GAS LLC 2323.00 209.00 365
2018 VANGUARD OIL & GAS LLC 3073.00 499.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 VANGUARD OIL & GAS LLC Brine 450 365
2011 VANGUARD OIL & GAS LLC Brine 105
2012 VANGUARD OIL & GAS LLC Brine 75 366
2013 VANGUARD OIL & GAS LLC Brine 155 365
2014 VANGUARD OIL & GAS LLC Brine 90 365
2015 VANGUARD OIL & GAS LLC Brine 40 365
2016 VANGUARD OIL & GAS LLC Brine 95 365
2017 VANGUARD OIL & GAS LLC Brine 0 365
2018 VANGUARD OIL & GAS LLC Brine 50 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-821132681 2014-10-16 0:00 PL No Violations
0040377435 2017-07-28 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1684. RBDMS indicated the production reporting was current. The road, well and tank battery locations were stable. The well was located in a pasture field with a fenced perimeter to prevent access from livestock. The 4.5 production casing was equipped with an electric pump jack. No identification was present at the well head. No leaks were detected at the well head. The tank battery was shared with 2-0927. Equipment specific to 2-1684 consisted of one (1) horizontal separator and one (1) 210 bbl production tank. The separator remained in good repair and contained a current 7 day chart. The production tank remained in good repair. Correct identification was present. Valves were closed and plugged. An earthen dike that was stable and free of fluid was present around the equipment. While on location I contacted Russell Miller Jr. at Vanguard to request identification be posted within one week at the well head. I will schedule a follow up inspection to document that identification was posted.
0312959725 2017-10-25 Production Wells No Violations The purpose of my inspection was to document the posting of identification on well #2-1684. The owner has posted correct identification at the well head. No further action was necessary.
0821132681 2014-10-16 Preliminary Restoration No Violations I was on site to conduct a preliminary restoration inspection. The tank battery is shared between #20927 (Kiko #2) and #21683 (Kiko-Berger #1A). Identification was posted on the tank battery. The tank battery consists of two 210 bbl production tank, a 50 bbl brine tank, and two horizontal separators. The tank valves are plugged. There are meter boxes with current charts showing production. The dike is present and in good repair. The GPS coordinates to the access for the tank battery are 40.83595, -80.95331 +/-8 ft. The wellhead is equipped with an electric pumpjack. The access road and site are stable. Preliminary restoration has passed.
0872956066 2008-10-21 Drill / Deepen / Reopen No Violations Inspection revealed that G&H Drilling is drilling shale at this time. No violations at this time.
312959725 2017-10-25 0:00 PW No Violations 0.20
40377435 2017-7-28 0:00: PW No Violations 0.50
872956066 2008-10-21 0:00 DD No Violations 0.50

For data sources see[9]

References