X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-21567

Well Details

Well ID: 34-029-21567
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Knox Township
Operator Name: G & O RESOURCES LTD
Well Pad ID:
Farm/Lease Name: DENNY DONALD L
License Status: Producing
License Date: 1993-07-28
Spud Date: 1993-08-28
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1993-09-13
Well Total Depth: 8434.00 ft
Configuration: Vertical
Latitude: 40.870000
Longitude: -80.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1993-07-28 Issued Date 7/28/93 Expired Date 7/28/94 Acres 0098430 Tool Type RTA Proposed Formation ROSE RUN Proposed Depth 08434 Proposed Drill Depth 08434
Original Spud 1993-08-28 LOG TYPE=FRLL
Completed 1993-09-13 LOG TYPE=FRLL
Reached Total Depth 1993-09-13 LOG TYPE=FRLL
Plugged Back 1993-09-14 LOG TYPE=FRLL
CO 1993-10-06 8 BLAIR BILL INC GeoDate 7/28/93
Completion Report Received 1993-10-25 LOG TYPE=FRLL
Construction Permit Expires 1994-07-28 LOG TYPE=FRLL
CO 1995-01-19 4659 BALL RESOURCES INC GeoDate 7/28/93
Change of Owner 2001-09-13 Operator changed from 4659, BALL RESOURCES INC to 5894, G & O RESOURCES LTD
Record Last Modified 2015-09-24 LOG TYPE=FRLL

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5332 5479 0
5332 5479 0
2006-09-11 5364 5420 56
5364 5420 56
5332 5479 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 63435 Gal 55000 FRAC W/63,435 GAL H20 & 55M# SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1993 BLAIR BILL INC 5714.00 211.00 38
1994 BLAIR BILL INC 35086.00 650.00 365
1995 BALL RESOURCES INC 19255.00 386.00 365
1996 BALL RESOURCES INC 12975.00 189.00 365
1997 BALL RESOURCES INC 10551.00 109.00 365
1998 BALL RESOURCES INC 11545.00 227.00 365
1999 BALL RESOURCES INC 9681.00 105.00 365
2000 BALL RESOURCES INC 8129.00 90.00 365
2001 G & O RESOURCES LTD 3127.00 0.00 365
2002 G & O RESOURCES LTD 7380.00 105.00 365
2003 G & O RESOURCES LTD 4429.00 98.00 365
2004 G & O RESOURCES LTD 7584.00 0.00 365
2005 G & O RESOURCES LTD 5659.00 85.00 365
2006 G & O RESOURCES LTD 5821.00 90.00 365
2007 G & O RESOURCES LTD 5537.00 0.00 365
2008 G & O RESOURCES LTD 5329.00 96.00 366
2009 G & O RESOURCES LTD 5163.00 93.00 365
2010 G & O RESOURCES LTD 4910.00 68.00 365
2011 G & O RESOURCES LTD 4197.00 53.00 365
2012 G & O RESOURCES LTD 3458.00 51.00 366
2013 G & O RESOURCES LTD 3988.00 0.00 365
2014 G & O RESOURCES LTD 3427.00 0.00 365
2015 G & O RESOURCES LTD 4159.00 68.00 365
2016 G & O RESOURCES LTD 3066.00 73.00 365
2017 G & O RESOURCES LTD 2843.00 34.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1993 BLAIR BILL INC Brine 20 38
1994 BLAIR BILL INC Brine 257 365
1995 BALL RESOURCES INC Brine 38 365
1996 BALL RESOURCES INC Brine 38 365
1997 BALL RESOURCES INC Brine 35 365
1998 BALL RESOURCES INC Brine 35 365
1999 BALL RESOURCES INC Brine 0 365
2000 BALL RESOURCES INC Brine 24 365
2001 BALL RESOURCES INC Brine 38 182
2002 G & O RESOURCES LTD Brine 38 365
2003 G & O RESOURCES LTD Brine 0 365
2004 G & O RESOURCES LTD Brine 0 365
2005 G & O RESOURCES LTD Brine 35 365
2006 G & O RESOURCES LTD Brine 0 365
2007 G & O RESOURCES LTD Brine 35 365
2008 G & O RESOURCES LTD Brine 0 366
2009 G & O RESOURCES LTD Brine 0 365
2010 G & O RESOURCES LTD Brine 0 365
2011 G & O RESOURCES LTD Brine 0 365
2012 G & O RESOURCES LTD Brine 0 366
2013 G & O RESOURCES LTD Brine 0 365
2014 G & O RESOURCES LTD Brine 20 365
2015 G & O RESOURCES LTD Brine 0 365
2016 G & O RESOURCES LTD Brine 0 365
2017 G & O RESOURCES LTD Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1227985003 2017-11-28 0:00 PW No Violations 0.40
-1857193320 2014-9-30 0:00: PW No Violations
0000007419 Preliminary Restoration No Violations PASSED Y WITNESSED 5/25/94 INSPECTOR BRETT FARNSWORTH DATE 05/2519/94 DATA FROM OLD VAX INFO
0462968967 2013-06-27 Production Wells No Violations

-up inspection.

0577469894 2005-01-25 Production Wells No Violations The tank battery consists of 1-210 bbl storage tank, 1-1,600 gallon plastic salt water tank and a dike.
1227985003 2017-11-28 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-1567. RBDMS indicated production reporting was current. Access and locations were stable. The 8.625 well head was below grade. The 4.5 production casing was equipped with an electric pump jack. Correct identification was present. No leaks were observed. Staining consistent with a legacy operation was present. The tank battery consisted of one (1) horizontal separator, one (1) 210 bbl production tank and one (1) 1610 gallon poly brine tank. The separator was positioned outside of the dike. The separator remained in good repair and contained a current 7 day production chart. A stable earthen dike that was free of fluid was constructed around the production and brine tank. The production tank remained in good repair and contained correct identification. Valves were closed and plugged. The poly brine tank remained in good repair. The inlet valve was closed. No violations were observed during this inspection.
1372275953 2013-06-24 Production Wells Violations Noted Juan Barreto of the ODNR had visited the site on 06/14/2013 to review the site for final restoration, as RBDMS indicated that the well was plugged and abandoned. Mr. Barreto found that the well was not plugged, but appeared to still be in production. He also found that inside the diked area surrounding the 210 bbl storage tank, oil was floating on water, and the tank had oil on the outside from the top down. No oil was found outside the diked area. He referred the site to me. I was able to get to the site for an inspection on June 24, 2013. I found that the well was in production. Equipment at the site consists of a pumpjack, a horizontal separator with a gas meter/motor valve enclosure, a 1600 gallon plastic brine storage tank, and a 210 bbl oil storage tank. Valves at the well head were open. I checked the electric box at the pump, and the power to the pumpjack was turned off at the time of the inspection. I found that the electric conduit from the power box to the pump was corroded through, exposing plastic-coated wiring. Two of the three drive belts on the pumpjack motor were broken. At the separator, I found a chart indicating the well was actively producing gas. The chart had last been changed on 06/20/2013. The separator was not inside the diked area where the brine and oil storage tanks were located. Inside the diked area, there was some oil on water in two corners, and oil staining on areas of the limestone gravel. I found the brine drainage line from the oil storage tank on the ground, and not connected to the brine storage tank. There were no padlocks on either the brine discharge line valve, or the oil line valve on the 210 bbl storage tank. There was a plug in the oil line valve. The 210 bbl tank had oil on the sides of the tank all the way around. I went up the stairs to the top of the tank to determine the source of the oil. I found that a short pipe in the dump line from the separator connecting the top of the storage tank was br
1378827934 2013-07-17 Production Wells No Violations I went to the site to inspect corrective action taken in response to the Compliance Notice issued on June 27, 2013. All items had been addressed and corrected. There are no current violations.
1586538248 2013-06-14 Final Restoration No Violations All equipment still on site. Tank looks like it is leaking. Water in tank battery area contaminated with oil and brine. Contaminated water leaking out from under dike. Referred to Columbiana inspector Mr. Anderson. Access road Lat 40.87797 Long 080.98008.
1857193320 2014-09-30 Production Wells No Violations I was on site to conduct a status check. Identification was posted on the tank battery and wellhead. The tank battery consists of one 210 bbl production tank, a 50 bbl poly brine tank, and one horizontal separator. The tank valves are plugged. There is a meter box with a current chart showing production. The dike is present and in good repair. The wellhead is equipped with an electric pumpjack. The access road and site are stable.
462968967 2013-6-27 0:00: PW No Violations
577469894 2005-1-25 0:00: PW No Violations 0.50
7419 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1372275953 US-OH-111012 2015-02-06 General Safety
1372275953 US-OH-111013 2015-02-06 No SPCC dike/or failure to keep dike free of water or oil
1372275953 US-OH-111014 2015-02-06 Failure to have required locks, bull plugs
1372275953 US-OH-111015 2015-02-06 Dike or pit not able to prevent escape of brine or other wastes
1372275953 US-OH-111016 2015-02-06 Failure to keep dike or pit free of brine or other wastes

For data sources see[9]

References