Well Details

Well ID: 34-029-21540
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Center Township
Operator Name: MOORE RESOURCES LLC
Well Pad ID:
Farm/Lease Name: MANN UNIT
License Status: Producing
License Date: 1991-11-21
Spud Date: 1991-11-12
Spud Drilling Contractor: DOWNHOLE DRILLING
Final Drill Date: 1991-11-20
Well Total Depth: 6109.00 ft
Configuration: Vertical
Latitude: 40.730000
Longitude: -80.830000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1991-10-15 3069 MURNANE JOSEPH M GeoDate 10/15/91
Oil and Gas 1991-10-15 Issued Date 10/15/91 Expired Date 10/14/92 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1991-11-14 RL 11-23-91
Completed 1991-11-20 RL 11-23-91
Reached Total Depth 1991-11-20 RL 11-23-91
CO 1991-11-21 3069 MURNANE JOSEPH M GeoDate 11/21/91
Oil and Gas 1991-11-21 Issued Date 11/21/91 Expired Date 11/20/92 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06109 Proposed Drill Depth 06109
Completion Report Received 1991-12-27 RL 11-23-91
Construction Permit Expires 1992-11-20 RL 11-23-91
CO 1994-02-14 213 LOMAK OPERATING CO GeoDate 11/21/91
Change of Owner 2000-06-27 Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC
Change of Owner 2009-11-16 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 5660, S & S ENERGY CORPORATION
Change of Owner 2017-01-11 Operator changed from 5660, S & S ENERGY CORPORATION to 7988, MOORE RESOURCES LLC
Record Last Modified 2017-02-15 RL 11-23-91

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5882 5963 0
5882 5963 0
2006-09-11 5890 5956 3
5890 5956 3
5882 5963 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 91500 0 FRAC W/91,500 BBL SAND LADEN WATER

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 COLUMBUS OILFIELD EXPLORATION 14329.00 0.00 275
1993 COLUMBUS OILFIELD EXPLORATION 9242.00 0.00 365
1994 RANGE OPERATING COMPANY 6840.00 0.00 365
1995 RANGE OPERATING COMPANY 6461.00 0.00 365
1996 RANGE OPERATING COMPANY 4645.00 0.00 365
1997 RANGE OPERATING COMPANY 4625.00 0.00 365
1998 RANGE OPERATING COMPANY 3434.00 0.00 365
1999 RANGE RESOURCES-APPALACHIA LLC 456.00 0.00 92
2000 RANGE RESOURCES-APPALACHIA LLC 3022.00 0.00 365
2001 RANGE RESOURCES-APPALACHIA LLC 2436.00 0.00 334
2002 RANGE RESOURCES-APPALACHIA LLC 1886.00 0.00 365
2003 RANGE RESOURCES-APPALACHIA LLC 1863.00 0.00 365
2004 RANGE RESOURCES-APPALACHIA LLC 1523.00 0.00 365
2005 RANGE RESOURCES-APPALACHIA LLC 1734.00 0.00 365
2006 RANGE RESOURCES-APPALACHIA LLC 2304.00 0.00 365
2007 RANGE RESOURCES-APPALACHIA LLC 1012.00 0.00 303
2008 RANGE RESOURCES-APPALACHIA LLC 813.00 0.00 273
2011 S & S ENERGY CORP 3703.00 0.00 365
2013 S & S ENERGY CORP 1193.00 0.00 365
2014 S & S ENERGY CORP 1287.00 0.00 365
2015 S & S ENERGY CORP 854.00 0.00 357
2016 S & S ENERGY CORP 1411.00 0.00 365
2017 MOORE RESOURCES LLC 1770.00 0.00 365
2018 MOORE RESOURCES LLC 655.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 COLUMBUS OILFIELD EXPLORATION Brine 483 275
1993 COLUMBUS OILFIELD EXPLORATION Brine 135 365
1994 RANGE OPERATING COMPANY Brine 185 365
1995 RANGE OPERATING COMPANY Brine 53 365
1996 RANGE OPERATING COMPANY Brine 185 365
1997 RANGE OPERATING COMPANY Brine 0 365
1998 RANGE OPERATING COMPANY Brine 365
1999 RANGE OPERATING COMPANY Brine 0 273
2000 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2001 RANGE RESOURCES-APPALACHIA LLC Brine 76 334
2002 RANGE RESOURCES-APPALACHIA LLC Brine 76 365
2003 RANGE RESOURCES-APPALACHIA LLC Brine 40 365
2004 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2005 RANGE RESOURCES-APPALACHIA LLC Brine 0 365
2006 RANGE RESOURCES-APPALACHIA LLC Brine 70 365
2007 RANGE RESOURCES-APPALACHIA LLC Brine 0 303
2008 RANGE RESOURCES-APPALACHIA LLC Brine 80 273
2011 S & S ENERGY CORP Brine 0 365
2013 S & S ENERGY CORP Brine 40 365
2014 S & S ENERGY CORP Brine 0 365
2015 S & S ENERGY CORP Brine 0 357
2016 S & S ENERGY CORP Brine 1 365
2017 MOORE RESOURCES LLC Brine 0 365
2018 MOORE RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-182959234 2013-8-5 0:00:0 PW No Violations
-342346224 2015-4-16 0:00: PW No Violations
-380134793 2019-7-30 0:00: PW No Violations 1.00
-753152045 2014-12-31 0:00 PW No Violations
-882437849 2013-8-14 0:00: PW No Violations
0000002300 Preliminary Restoration No Violations PASSED Y WITNESSED 1/15/93 INSPECTOR BRETT FARNSWORTH DATE 01/1519/93 DATA FROM OLD VAX INFO
0182959234 2013-08-05 Production Wells No Violations
0342346224 2015-04-16 Production Wells Violations Noted I was onsite to conduct a follow-up inspection. On 12/31/2014 I conducted a status check where I observed that the identification was incomplete, the tank needed a plug, and the dike was insufficient and breached in two spots. I contacted Pep Horning, pumper for S&S Energy, on 1/6/2015 regarding the violations. Upon reinspection, the identification, tank valve plug, and dike issues still remain and have not been resolved. A compliance notice is being issued requiring that the well be properly identified, the valve on the production tank be locked or secured with a plug, and the dike be repaired and raised.
0746776247 2014-02-12 Production Wells No Violations I was at the site to check on the final repairs that had been done to the wellhead. I found the wellhead completely repaired, and the well in production. A new ID sign was also on the well. The repairs were done to repair a leak in the tubing below the tubing valve on the plunger-lift assembly. I had originally called the company regarding the leak on 8/05/13 in response to the landowners call regarding the leak. I spoke with Mr. Earl Horning of S&S Energy on 8/05/13. He responded promptly by placing a clamp on the leaking tubing, and subsequently replaced the leaking tubing. During my follow-up inspection on 8/14/13, I had found the tubing replaced and leak repaired, but the wellhead piping was not entirely connected. During a phone call from me on 8/14/13, Mr. Horning indicated that he needed some additional parts to complete the repair and place the well back into production. My inspection today was to follow up on those repairs.
0753152045 2014-12-31 Production Wells No Violations I was on site to conduct a status check. Identification was posted at the wellhead and tank battery but incomplete at tank battery. The tank battery consists of one 100 bbl production tank and one vertical separator. The tank valves are not plugged. There is a meter box with a current chart showing production. The dike is present but is in poor condition and needs to be brought up in several places. The wellhead is equipped as a plunger lift with a domestic supply line. The access road and site are stable. The operator will be contacted to address of the identification, tank plugging, and dike issues.
0882437849 2013-08-14 Production Wells No Violations On 08/09/2013, I received a call from Earl Horning of S&S Energy regarding the repairs to the tubing leak on the wellhead. Mr. Horning indicated that the repairs were in progress. The corroded and leaking tubing was to be removed, and a new tubing valve would be installed. I stopped at the site to follow up on these repairs. I found the well shut in, the tubing repaired, and a new tubing valve installed. No gas was leaking. The piping for a portion of the well head was not completely together. I called Mr. Horning regarding this situation, and he indicated he had to secure some parts to complete the task. He was going to try to have the plumbing fully connected by Friday 08/16/2013.
1472141804 2016-08-15 Production Wells No Violations The purpose of my inspection was to conduct a compliance notice follow-up. On 4/22/2015, Inspector Joshua Schiering issued a compliance notice due to incomplete well identification, a missing plug on the production tank and for an insufficient dike. Upon my inspection, the well head was properly identified. No audible or visual leaks were identified. A domestic supply was present. The tank battery consisted of a vertical separator and a 100 bbl production tank. A current chart indicating production was in the meter house. No audible or visual leaks were identified. The production tank was in good repair. I did not observe any leaks. The load line valve was shut and plugged. The heater tube access was obstructed with a plastic bucket. The top hatch was closed. An earthen dike was constructed around the production equipment and stabilized with vegetation. RBDMS indicates reported production through 2014. I will contact S&S Energy concerning production reporting. The compliance notice can be closed.
1567000036 2019-8-28 0:00: PW No Violations 1.00
1721959060 2019-12-18 0:00 PW No Violations 1.00
2300 PL No Violations
746776247 2014-2-12 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0342346224 US-OH-123579 2015-05-11 Failure to legibly identify well
0342346224 US-OH-123580 2015-05-11 No SPCC dike/or failure to keep dike free of water or oil
0342346224 US-OH-123581 2015-05-11 Failure to have required locks, bull plugs

For data sources see[9]