Well Details

Well ID: 34-029-20728
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Perry Township
Operator Name: SANOR BRUCE
Well Pad ID:
Farm/Lease Name: COY J
License Status: Producing
License Date: 1977-04-29
Spud Date: 1977-09-25
Spud Drilling Contractor:
Final Drill Date: 1977-12-17
Well Total Depth: 5860.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -80.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1977-04-29 3126 SANOR LLOYD GeoDate 4/29/77
Original Spud 1977-09-25
Completed 1977-12-17
Reached Total Depth 1977-12-17
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5663 5760 1
5663 5760 1
5663 5760 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 500 Gal 57900

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 ZILKHA ENERGY INC 169.00 235.00 364
1987 ZILKHA ENERGY INC 907.00 197.00 303
2001 SANOR BRUCE 115.00 179.00 120
2006 SANOR BRUCE 110.00 223.00 365
2007 SANOR BRUCE 64.00 162.00 365
2008 SANOR BRUCE 159.00 226.00 365
2009 SANOR BRUCE 144.00 168.00 365
2010 SANOR BRUCE 161.00 167.00 365
2011 SANOR BRUCE 132.00 169.00 365
2012 SANOR BRUCE 60.00 168.00 366
2013 SANOR BRUCE 819.00 179.00 365
2014 SANOR BRUCE 0.00 158.00 365
2015 SANOR BRUCE 62.00 139.00 365
2016 SANOR BRUCE 32.00 164.00 365
2017 SANOR BRUCE 116.00 113.00 365
2018 SANOR BRUCE 80.00 168.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 ZILKHA ENERGY INC Brine 95 364
1987 ZILKHA ENERGY INC Brine 54 303
2001 SANOR BRUCE Brine 30 120
2006 SANOR BRUCE Brine 15 365
2007 SANOR BRUCE Brine 14 365
2008 SANOR BRUCE Brine 8 365
2009 SANOR BRUCE Brine 7 365
2010 SANOR BRUCE Brine 5 365
2011 SANOR BRUCE Brine 7 365
2012 SANOR BRUCE Brine 7 366
2013 SANOR BRUCE Brine 8 365
2014 SANOR BRUCE Brine 6 365
2015 SANOR BRUCE Brine 8 365
2016 SANOR BRUCE Brine 8 365
2017 SANOR BRUCE Brine 5 365
2018 SANOR BRUCE Brine 8 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1483992473 2017-01-09 Production Wells No Violations The purpose of my inspection was to conduct a status check of well # 2-0728. RBDMS indicates the Owner is current with reporting production. Lease access is through a residential driveway leading to grassland. The well and tank battery are within view of each other. The well location is stable with well-established vegetation. Identification is not present at the wellhead. The 8.625 well head is below grade. The 4.5 production casing is equipped with an electric powered pump jack. No audible or visual leaks were identified. A domestic supply connection was present. The tank battery is shared with #2-0851. Production equipment is contained within an earthen dike that is stable with well-established vegetation. An area on the South side of the dike is worn and creates a clear and present hazard in the event of an equipment failure. Equipment within the dike consists of one (1) diaphragm meter one (1) 210 bbl production tank and one (1) 1200 gallon poly brine tank.. The meter remained in good repair. No audible or visual leaks were identified. The production tank contained an identification sign with illegible identification. No leaks were identified on the tank body. The load line valve was closed with a pup joint extension to facilitate loading. The pup joint contained a valve in the closed position and was plugged. The hatch lid was closed. The poly brine tank remained in good repair with no detected cracks or leaks. The tank was standalone and had no plumbing in or out. A plug was present in the bottom of the tank. The tank contained approximately 1000 gallon of fluid according to the graduated marks on the tank side. I met owner Bruce Sanor at an offset well and communicated the need to improve the dike to fully contain a release and to update the identification to reflect both wells being produced into the tank battery. Mr. Sanor acknowledged the illegible identification and stated he would have the sign updated within a week and would i