34-029-20523

Well Details

Well ID: 34-029-20523
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: West Township
Operator Name: FOLTZ & FOLTZ LTD PARTNERSHIP
Well Pad ID:
Farm/Lease Name: D W SANOR
License Status: Final Restoration
License Date: 2017-09-12
Spud Date: 1959-11-10
Spud Drilling Contractor:
Final Drill Date: 1959-12-18
Well Total Depth: 842.00 ft
Configuration: Vertical
Latitude: 40.780000
Longitude: -81.020000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1959-11-10
Completed 1959-12-18
Reached Total Depth 1959-12-18
Completion Report Received 1960-02-16
CO 1977-07-11 475 R & E ENTERPRISES GeoDate 7/11/77
Change of Owner 2004-10-28 Operator changed from 475, R & E ENTERPRISES to 146, FOLTZ & FOLTZ ENTP
Plugged/Abandoned 2017-08-21
APP 2017-09-12 Proposed Formations:BEREA, Issued Date:9/12/2017, Expired Date:9/12/2019 12:00:00 PM, Drilling unit acres:123.85, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2018-06-16
Construction Permit Expires 2019-09-12

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2014 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP 0.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1826357599 2017-8-17 0:00: PB No Violations 0.10
0677905724 2018-06-12 Final Restoration No Violations The purpose of my inspection was to determine the status of final restoration on well #2-0523. At the time of my inspection, the working pit was backfilled and the location graded to local contour. The location was within a woodland. Vegetation was established. No signs of erosion or sedimentation were observed. All equipment and debris utilized in plug and abandonment was removed. The access road was reclaimed. The location has passed the requirements for final restoration.
1826357599 2017-08-17 Plug / Plug Back No Violations The purpose of my inspection was to witness the top of cement in well #2-0523 set on 8.16.2017. The top of cement was approximately 20 feet below surface. Per owner Bob Foltz the plug will get topped off during the next plug operation. The location remained stable. The earthen pit had been emptied and backfilled. No violations were observed during this inspection.
1948098446 2015-11-18 Production Wells No Violations My inspection found the well to be equipped with 8 1/4 casing, 6 5/8 casing, and 5 3/16 casing. There is 2 tubing and rods in the well. The pump jack has been removed from the well. The annulus is open to the atmosphere. The tank battery has been removed by the well owner. There is no known production ever recorded for the well. The well owner is currently working to plug other berea wells on the property.
2057095862 2017-08-16 Plug / Plug Back No Violations The purpose of my inspection was to witness the surface plug set in well #2-0523. Owner Bob Foltz reported removing the 5 production casing and 7 surface casing. A tremie line of 2 tubing was installed in the well to 530. R.W. Sidley delivered 4.75 yards of 9 sack grout. The grout was placed down the annulus of the tubing until and flow was established. Grout continued to be poured until flow stopped. Mr. Foltz pulled tubing from the hole until the string pulled dry. The remaining grout was placed into the annular space and came to surface. The remaining tubing was then removed from the well and remained near surface. I will schedule to witness the cement top. No violations were observed during this inspection.
677905724 2018-6-12 0:00: FR No Violations 0.20

For data sources see[7]