X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-20513

Well Details

Well ID: 34-029-20513
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Salem Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: WINDRAM WALTER & CLARA
License Status: Storage Well
License Date: 1958-11-07
Spud Date: 1958-11-13
Spud Drilling Contractor:
Final Drill Date: 1959-01-19
Well Total Depth: 863.00 ft
Configuration: Vertical
Latitude: 40.820000
Longitude: -80.750000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1958-11-13
Completed 1959-01-19
Reached Total Depth 1959-01-19
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R.P. 48 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1381507282 2016-12-5 0:00: SO No Violations
0173993934 2015-04-21 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0236796451 2017-02-21 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0513. The lease road was stable and in good repair. The well location was within an agricultural field that was stable. Correct and legible identification was posted at the well head. The well head was fitted with closed and plugged valves in both side ports. The well head was equipped with master gate valve plumbed to a side gate valve. The side gate valve was plumbed out to a 4.0 flow line that lead to a vertical drip. The outlet of the drip was plumbed to the main line. A domestic supply connection was present. No audible or visual leaks were detected. No violations were observed during this inspection.
0414591825 2014-11-05 Storage Well No Violations I inspected Columbia Gas storage well #4492. The well is equipped with a master gate valve and a side gate valve. There was no storage tank associated with the well. There storage well supplied natural gas to a domestic meter. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable. No violations found.
1012951114 2019-02-21 Storage Well No Violations This storage well was equipped with a flanged wellhead with a master gate valve and a wing valve. Proper identification was posted. The access road was stable. No violations were observed at the time of inspection.
1368015144 2013-05-08 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4492 today. The well is located in Section 25, Salem Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve and a needle valve. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
1381507282 2016-12-05 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1551493499 2020-1-13 0:00: SO No Violations 1.00
173993934 2015-4-21 0:00: SO No Violations
1982886362 2018-02-12 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #20513. Access to the well was stable and drivable. Correct identification was posted at the well. The surface casing was plumbed above grade. Annular valves were closed to atmosphere. The production casing was equipped with a master gate and a wing valve connected to a 4.5 line leading to a vertical drip before the lead line. A domestic supply connection was present. No leaks were observed. No violations were observed during this inspection.
236796451 2017-2-21 0:00: SO No Violations 0.40
414591825 2014-11-5 0:00: SO No Violations 0.50
677771851 2019-10-2 0:00: SO No Violations 1.00

For data sources see[4]

References