34-029-20487

Well Details

Well ID: 34-029-20487
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: WRIGHT RAY & LAURA
License Status: Storage Well
License Date: 1957-10-25
Spud Date: 1957-11-15
Spud Drilling Contractor:
Final Drill Date: 1957-12-06
Well Total Depth: 775.00 ft
Configuration: Vertical
Latitude: 40.800000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1957-11-15
Completed 1957-12-06
Reached Total Depth 1957-12-06
Record Last Modified 2011-08-17

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 R,P. 72 HRS.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1085079793 2019-8-15 0:00: SO No Violations 1.00
-1363238359 2014-11-12 0:00 SO No Violations
-147527204 2015-1-21 0:00: SO No Violations
-1813583879 2013-5-30 0:00: SO No Violations
-230227652 2018-8-13 0:00: SO No Violations 0.40
-480590931 2016-10-11 0:00 SO No Violations
0139555975 2017-02-14 Storage Well No Violations The purpose of my inspection was to conduct an annual status check on well #2-
0147527204 2015-01-21 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0230227652 2018-08-13 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0487. Access remained drivable and stable. Correct identification was present. No leaks were observed. The surface casing well head assembly was above grade and closed to atmosphere. The assembly was topped with a snubbing assembly composed of a gate valve, flow cross, and a pair of wing valves. The East side of the well was connected to a vertical drip before field system.
0480590931 2016-10-11 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. There was a domestic line with a meter. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1038385636 2020-1-23 0:00: SO No Violations 1.00
1363238359 2014-11-12 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4449. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs through a drip tank and goes into the main line. The annulus valve is plumbed up and closed. There was a sales line with a separator. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
139555975 2017-2-14 0:00: SO No Violations 0.40
1813583879 2013-05-30 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4499 today. The well is located in Section 6, Elk Run Township, Columbiana County, Ohio. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4 lead line that goes into the main line. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.

For data sources see[4]