34-029-20435

Well Details

Well ID: 34-029-20435
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Elkrun Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: J & L B MORLAN #1
License Status: Storage Well
License Date: 2020-03-24
Spud Date: 1955-09-30
Spud Drilling Contractor:
Final Drill Date: 1955-11-16
Well Total Depth: 781.00 ft
Configuration: Vertical
Latitude: 40.780000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1955-09-30
Completed 1955-11-16
Reached Total Depth 1955-11-16
Change of Owner 2011-08-05 Operator changed from 9998, HISTORIC OWNER to 22, COLUMBIA GAS TRANSMISSION
Record Last Modified 2011-08-17

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1093046293 2016-12-7 0:00: SO No Violations
-1259583254 2015-9-24 0:00: SO No Violations
-1576467800 2020-6-17 0:00: PB No Violations 8.00
-1774253990 2019-8-15 0:00: SO No Violations 1.00
-228773010 2020-1-21 0:00: SO No Violations 1.00
-655684634 2016-10-11 0:00 SO No Violations
0234397297 2018-08-13 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0435. Access remained drivable and stable. Correct identification was present. No leaks were observed. Well 0435 is an observation well. The surface casing annulus was above grade and was open to atmosphere. A 7 x 2 swage was fitted to the casing was and contained a closed and plugged valve for operations.
0419284249 2017-10-04 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #6-0435. The lease access and well location were stable. Correct identification was present. The well was an observation well. Annular side ports were open to atmosphere. The well casing was swaged to a 2 valve that was closed and plugged. No leaks were observed. No violations were observed during this inspection.
0655684634 2016-10-11 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed up to a side gate valve. The side gate valve is plumbed into a 4.00 lead line that runs into the main line. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
0937779598 2014-12-08 Storage Well No Violations I inspected Columbia Gas Transmission gas well #4345. The well is equipped with a master gate valve that is plumbed into a needle valve. The annulus valve is plumbed up and closed. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1093046293 2016-12-07 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve that is plumbed into a 4.5 inch casing with a Swage nipple valve and a bull plug. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1259583254 2015-09-24 Storage Well No Violations I conducted a status check on this well. The well is equipped with casing plumbed to a Swage nipple valve into a 2 inch gate valve and topped with a plug. The well is properly identified with a clear, legibly marked well identification sign. The lease road is in stable condition and drivable. No violations found.
1592575139 2020-6-16 0:00: PB No Violations 8.00
1592835532 2020-6-22 0:00: FR No Violations 1.00
2131841059 2013-12-10 Storage Well No Violations I inspected Columbia Gas Transmission gas well # 4345 today. The well is located in Elk Run Township, Columbiana County, Ohio. The well is considered to be an observation well. The well is equipped with a master gate valve that is plumbed up to a swedge with a fitting on it for a gauge. The annulus valve is plumbed up and is closed. There is no tank on location. The well is properly identified with a clear, legible identification sign. The lease road is in stable condition. No violations found.
234397297 2018-8-13 0:00: SO No Violations 0.30
419284249 2017-10-4 0:00: SO No Violations
937779598 2014-12-8 0:00: SO No Violations

For data sources see[3]

References