Well Details

Well ID: 34-029-20152
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: Knox Township
Operator Name: DOMINION EAST OHIO
Well Pad ID:
Farm/Lease Name: WAFLER-STANLEY
License Status: Storage Well
License Date:
Spud Date: 1945-05-14
Spud Drilling Contractor:
Final Drill Date: 1945-07-09
Well Total Depth: 3527.00 ft
Configuration: Vertical
Latitude: 40.860000
Longitude: -80.980000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1945-05-14 GL=1097.65, STORAGE I.P. = 879,840 CFG.
Completed 1945-07-09 GL=1097.65, STORAGE I.P. = 879,840 CFG.
Reached Total Depth 1945-07-09 GL=1097.65, STORAGE I.P. = 879,840 CFG.
Record Last Modified 2009-12-11 GL=1097.65, STORAGE I.P. = 879,840 CFG.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 90 Qts 0 R.P. 24 HRS.
GEL 0 490 Lbs 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 DOMINION EAST OHIO 0.00 0.00 0
2003 DOMINION EAST OHIO 0.00 0.00 0
2004 DOMINION EAST OHIO 0.00 0.00 0
2005 DOMINION EAST OHIO 0.00 0.00 0
2006 DOMINION EAST OHIO 0.00 0.00 0
2007 DOMINION EAST OHIO 0.00 0.00 0
2008 DOMINION EAST OHIO 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 DOMINION EAST OHIO Brine 0 0
2003 DOMINION EAST OHIO Brine 0 0
2004 DOMINION EAST OHIO Brine 0 0
2005 DOMINION EAST OHIO Brine 0 0
2006 DOMINION EAST OHIO Brine 0 0
2007 DOMINION EAST OHIO Brine 0 0
2008 DOMINION EAST OHIO Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1793792426 2018-6-12 0:00: SO No Violations 0.30
-1940060114 2020-1-9 0:00:0 SO No Violations 1.00
-2070026484 2016-12-7 0:00: SO No Violations
-23655668 2015-10-5 0:00: SO No Violations
-666120831 2019-9-10 0:00: SO No Violations 1.00
-685095664 2013-3-7 0:00:0 SO No Violations
-703460154 2014-12-4 0:00: SO No Violations
-891928961 2017-10-3 0:00: SO No Violations 0.30
0023655668 2015-10-05 Storage Well No Violations I conducted a status check on this well. The well is equipped with a master gate valve and a side gate valve. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) tank drains on the storage tank and they are secured with valves and bull plugs in place. There is a domestic line with a meter. The tank battery is diked. The well is not properly identified with a clear, legibly marked well identification sign and needs the ownership information to be updated. The lease road is stable and drivable.
0685095664 2013-03-07 Storage Well No Violations I inspected Dominion East Ohio gas well # 1977 today. The well is located in Section 13, Knox Township, Columbiana County, Ohio. The well is equipped with a master gate valve, a side gate valve with a 4 daniels run plumbed into the main line. There is a flow gate with a 3 line plumbed into a 100 BBL storage tank. All lids and hatches are closed and secured. Two (2) pickup lines on the storage tank and they are secured with valves and bullhead plugs. The well is properly identified with a clear, legible identification sign mounted on the main line. The lease road is in stable condition. No violations found.
0703460154 2014-12-04 Storage Well No Violations I inspected Lake Shore Gas storage well #1977. The well is equipped with a master gate valve and a side gate valve. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) pickup lines on the storage tank and they are secured with valves and bull plugs in place. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stoned and drivable. No violations found.
0891928961 2017-10-03 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0152. The lease access and well location were stable. Correct identification was present. The well casing was equipped with a master gate valve, two (2) side gate valves and a flow line out to a flow gate valve. No leaks were observed. One (1) 100 bbl fluid tank contained with an earthen dike was on location. The tank remained in good repair. Valves were closed and plugged. No violations were observed during this inspection. Owner identification needs updated in RBDMS.
1230920603 2004-05-05 Production Wells No Violations The tank battery consists of 1-100 bbl storage tank and a dike.
1230920603120513 2004-5-5 0:00:0 PW No Violations 0.50
1230920603156836 2004-5-5 0:00:0 SO No Violations 0.50
1793792426 2018-06-12 Storage Well No Violations The purpose of my inspection was to conduct a status check on well #2-0152. Access to the well remained drivable and stable. Identification at the well head indicated Lake Shore Gas Storage as the owner. The well head annulus was plumbed above grade and closed to atmosphere. The injection casing was equipped with a master gate valve that was at grade. The master valve topped with a flow cross. The top of the cross contained an observation port. The sides of the cross contained wing valves. The South wing valve was connected to a 3.5 line. The North valve was out to a 4.5 line. All valves were closed. A 100 bbl steel production tank was on location. I observed holes due to corrosion in the West side of the tank approximately three feet above grade. No evidence of fluid loss was present. Valves were closed and plugged. No violations were observed during this inspection.
2070026484 2016-12-07 Storage Well No Violations At the time of this inspection, the well site was equipped with:



Signage needs updated due to change of ownership. I am currently researching information pertaining to the new owner of the well field. The lease access is stable and drivable. No other violations were observed.