X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-029-20120

Well Details

Well ID: 34-029-20120
Loading map...
Country: United States
State: Ohio
County: Columbiana
Municipality: St. Clair Township
Operator Name: C A JOSEPH COMPANY
Well Pad ID:
Farm/Lease Name: EIFERT JOHN
License Status: Final Restoration
License Date: 2011-05-18
Spud Date: 1942-09-01
Spud Drilling Contractor:
Final Drill Date: 1945-10-01
Well Total Depth: 865.00 ft
Configuration: Vertical
Latitude: 40.660000
Longitude: -80.610000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1942-09-01 WELL EXISTS AS PER JOHN PATRICK 1/21/03. DIRECTIONS TO LOCATION: WEST SIDE OF ANNESLEY ROAD BETWEEN THE ADDRESSES OF 16165 AND 16211. AND WEST OF 16203 (AEP ENERGY BUILDING). GPS ERROR = 16 FEET. LATITUDE = 40.66636; LONGITUDE = 080.61183. GL=1123.35. WELL HAS FR AS OF 1/2015 PER JOSH SCHIERING. 8/31/15. EAF
Completed 1945-10-01 WELL EXISTS AS PER JOHN PATRICK 1/21/03. DIRECTIONS TO LOCATION: WEST SIDE OF ANNESLEY ROAD BETWEEN THE ADDRESSES OF 16165 AND 16211. AND WEST OF 16203 (AEP ENERGY BUILDING). GPS ERROR = 16 FEET. LATITUDE = 40.66636; LONGITUDE = 080.61183. GL=1123.35. WELL HAS FR AS OF 1/2015 PER JOSH SCHIERING. 8/31/15. EAF
Reached Total Depth 1945-10-01 WELL EXISTS AS PER JOHN PATRICK 1/21/03. DIRECTIONS TO LOCATION: WEST SIDE OF ANNESLEY ROAD BETWEEN THE ADDRESSES OF 16165 AND 16211. AND WEST OF 16203 (AEP ENERGY BUILDING). GPS ERROR = 16 FEET. LATITUDE = 40.66636; LONGITUDE = 080.61183. GL=1123.35. WELL HAS FR AS OF 1/2015 PER JOSH SCHIERING. 8/31/15. EAF
APP 2011-05-18 Proposed Formations:BEREA, Issued Date:5/18/2011, Expired Date:5/17/2013 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2013-05-17 WELL EXISTS AS PER JOHN PATRICK 1/21/03. DIRECTIONS TO LOCATION: WEST SIDE OF ANNESLEY ROAD BETWEEN THE ADDRESSES OF 16165 AND 16211. AND WEST OF 16203 (AEP ENERGY BUILDING). GPS ERROR = 16 FEET. LATITUDE = 40.66636; LONGITUDE = 080.61183. GL=1123.35. WELL HAS FR AS OF 1/2015 PER JOSH SCHIERING. 8/31/15. EAF
Record Last Modified 2017-02-15 WELL EXISTS AS PER JOHN PATRICK 1/21/03. DIRECTIONS TO LOCATION: WEST SIDE OF ANNESLEY ROAD BETWEEN THE ADDRESSES OF 16165 AND 16211. AND WEST OF 16203 (AEP ENERGY BUILDING). GPS ERROR = 16 FEET. LATITUDE = 40.66636; LONGITUDE = 080.61183. GL=1123.35. WELL HAS FR AS OF 1/2015 PER JOSH SCHIERING. 8/31/15. EAF

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1319483171 2011-07-07 Plug / Plug Back No Violations On site with Inspector Corder to witness plugging operations. R.&S. Drilling plugged the well to surface thru one inch tubing. Cement circulated to surface and stayed at surface. They advised that they would like to leave the tubing in the well at this time. I advised since there was cement on the inside and the outside of the tubing that this was acceptable. Checked the well again before leaving the site and the cement was still at ground level. I advised that the well head / casing had to be cut off at least 30 below grade. I was advised that they were planning on cutting it off at least that deep and possibly deeper since they were going to construct a parking lot on top of the plugged well. There were no signs of any gas leakage at the time of our departure. Well has been properly plugged and abandoned at this time. No violations of Ch 1509 ORC or Ch 1501 OAC at this time.
1335145906 2011-07-07 Plug / Plug Back No Violations I was on site with DNR Inspector Andrew Corder to witness plugging operations. R&S Drilling plugged the well to surface thru one inch tubing. The cement circulated surface and remained there. The plugging crew stated that they wanted to leave the tubing in the well. Since there was cement on both the inside and outside of the tubing. I agreed to the request. We checked the well before leaving the site and found the cement was still at ground level and there was no signs of gas leakage. I advised the plugging crew that the wellhead / casing had to be cut off at least 30 below grade. They stated that they were planning on cutting it off at least that deep and possibly deeper since there were plans to construct a parking lot on top of the plugged well. No violations of CH 1509 ORC or CH 1501 OAC at this time.
1421846402 2015-01-20 Final Restoration No Violations I was onsite to conduct a status check requested by Erica Freeman. The well is listed in the state database as plugged and abandoned. A permit to plug the well was issued 5/18/2011. Inspector Brett Farnsworth reports witnessing the cementing of well on 7/7/2011 from bottom to top with cement circulating to surface. He state the well was to be cut off well below 30 inches because a parking lot was going to be installed on location overtop. Onsite, I saw no evidence of any well and the location is now the parking lot of the Columbiana Oil and Gas Company of Ohio. No evidence of tank battery or lines or any other production equipment could be found. Final Restoration has passed.

For data sources see[3]

References