34-019-22553

Well Details

Well ID: 34-019-22553
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Center Township
Operator Name: R E GAS DEVELOPMENT LLC
Well Pad ID: US-OH-000805
Farm/Lease Name: GRUNDER UNIT
License Status: Cancelled
License Date: 2018-01-23
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Horizontal
Latitude: 40.600000
Longitude: -81.080000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-12-04 Proposed Formations:UTICA-POINT PLEASANT, Issued Date:12/4/2013, Expired Date:12/4/2015 12:00:00 PM, Drilling unit acres:574.62, Proposed Well Type:OG, Proposed Well Class:NWC
APP 2017-05-19 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:5/19/2017, Expired Date:5/19/2019 12:00:00 PM, Drilling unit acres:596.48, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2018-01-23 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:1/23/2018, Expired Date:1/23/2020 12:00:00 PM, Drilling unit acres:596.48, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2018-10-16 STATUS CHANGED 05/11/2016
Construction Permit Expires 2020-01-23 STATUS CHANGED 05/11/2016

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1550330996 2018-4-6 0:00:0 PW No Violations 1.00
1419444133 2014-11-19 Production Wells No Violations On site with District Supervisor - Richard Anderson and Regional Supervisor - Tom Hill to conduct a status check on the production well number 8H. At the time of the inspection, the site was frozen and snow covered. The 6 wellheads had plunger lift units on them and were in production. The tank battery had 12 storage tanks, 6 sand separators, 6 gas processing units and 1 oil stabilizer. The tank battery was diked. The site also contained 1 main service line and 6 gas recovery units. During the inspection, Unit #2 of the gas recovery units had a leaking dump valve whose gas pressure fell below correct operating pressure and needed to be reset. Contacted the well tender to come out and reset the unit. The well tender arrived while we were still on the site and reset the operating pressure. There was no signage associated with the wellheads or tank battery. The lease road was stable and drivable.
1550330996 2018-04-06 Production Wells No Violations I performed a follow up inspection on this location. On 3/29/2018 there was a work over rig and a snubbing unit on location to pull tubing and replace because of sand problems. Other wells on the pad were still in production. The work over rig is off of location. The well is back in production. ID signs were posted. No noted violations at this time.

For data sources see[3]