34-019-22450

Well Details

Well ID: 34-019-22450
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Center Township
Operator Name: R E GAS DEVELOPMENT LLC
Well Pad ID: US-OH-000747
Farm/Lease Name: JENKINS UNIT
License Status: Cancelled
License Date: 2013-06-13
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.600000
Longitude: -81.060000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-06-13 Proposed Formations:UTICA/POINT PLEASANT/TRENTON, Issued Date:6/13/2013, Expired Date:6/13/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
Correction to Well 2013-11-01 CORRECTION TO WELL NUMBER
Construction Permit Expires 2015-06-13
Record Last Modified 2017-02-10

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-10-22 8029 13430 0
8029 13430 0
8029 13430 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/16/2014 07/02/2014 7707 8,763,890.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Rex Energy Carrier/Base Fluid Water 7732-18-5 100 86.5771 73,134,600.0
Sand (Proppant) Sargent/Momentive/Preffered Proppant Silica Substrate 14808-60-7 100 11.8472 10,007,700.0
Hydrochloric Acid (7.5%) PVS Acidizing Hydrochloric Acid 7647-01-0 7.5 0.111104 93853
Water 7732-18-5 92.5 1.37028 1,157,520.0
AP Breaker Sagar Enterprise Gel Breaker Ammonium Persulfate 7727-54-0 100 0.00003078 26
Slurry Gel, WGA-7 SLR PolyFrac Plus Gel Guar Gum 9000-30-0 45 0.00148408 1253.65
Petroleum Distillate 64742-47-8 45 0.00148408 1253.65
Clay 14808-60-7 5 0.000164898 139.295
Surfactant 154518-36-2 5 0.000164898 139.295
TEA Breaker Activater Sagar Enterprise Gel Breaker Triethanolamine 102-71-6 72.5 0.000611642 516.675
Diethanolamine 111-42-2 13 0.000109674 92.645
Friction Reducer, Unislick ST-50 CESI Chemical Friction Reducer Other - (non-hazardous) NA 70 0.0482505 40758.9
Petroleum distillates, hydrotreated light 64742-47-8 30 0.0206788 17468.1
Acid Inhibitor, Unihib G GeoSafe Acid Inhibitor Acetophenone 98-86-2 1 0.00000632 5.341
Ethoxylated alcohol 68002-97-1 35 0.000221278 186.921
Short Chained Glycol Ether 112-34-5 60 0.000379333 320.435
Formaldehyde 50-00-0 1 0.00000632 5.341
Methanol 67-56-1 5 0.00003161 26.703
Thiourea 62-56-6 1 0.00000632 5.341
Scale Inhibitor, ScaleHib A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00618102 5221.32
Other - (non-hazardous) NA 70 0.0144224 12183.1

For data sources see[4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2014 R E GAS DEVELOPMENT LLC Brine 4943 120
2015 R E GAS DEVELOPMENT LLC Brine 9419 353
2016 R E GAS DEVELOPMENT LLC Brine 4643 362
2017 R E GAS DEVELOPMENT LLC Brine 2895 288
2018 PENNENERGY RESOURCES LLC Brine 28167 350
2019 PENNENERGY RESOURCES LLC Brine 1174 89

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1441795230 2019-9-9 0:00:0 PW No Violations 1.00
-1619622062 2019-8-27 0:00: PW No Violations 0.80
-1768681298 2018-12-28 0:00 PW No Violations 1.00
-1808813381 2017-7-17 0:00: PW No Violations
-404109123 2018-6-27 0:00: PW No Violations 1.50
-660387845 2019-1-25 0:00: PW No Violations 1.00
-720953728 2019-1-25 0:00: PW No Violations
-823637601 2017-7-19 0:00: PW No Violations
0404109123 2018-06-27 Production Wells No Violations

I conducted a status check of the well and production pad. Six wells are located on the pad (permit numbers (22734, 22735, 22736, 22452, 224251, 22450. This well is equipped with plunger-lift configuration. The surface-intermediate annulus was equipped pressure relief valve and pressure gauge which displayed a reading of zero psi. Identification was posted at the well and lease entrance. The production tanks and production equipment were surrounded by a lined steel dike. The access road was stable and drivable. Erosional controls appeared to be functioning. Equipment on the pad consisted of the following: Nine 400 bbl production tanks; six labelled as containing condensate and four as containing produced water Six gas processing units with line heaters and vertical separators One combustor unit One vapor recovery unit One oil stabilization unit

0475395915 2017-06-21 Production Wells No Violations I conducted a status check of the well while on location for the Jenkins #7H intermediate cement job. No changes have been made since my last inspection. I did not locate a surface pressure gauge on the well head, but I contacted Shawn McGuigan of R.E Gas Development to have a gauge installed on the well head on 06/21/2017.
0660387845 2019-01-25 Production Wells No Violations I was on site for a compliance notice follow-up for lack of updated identification. Proper identification displaying the current owner was posted at the time of inspection. The surface/intermediate annular gauge displayed a reading of zero psi and the intermediate/production annular gauge displayed 880 psi. The compliance notice can be closed.
0769738907 2017-05-17 Production Wells No Violations I conducted a status check of this well. I did not conduct a preliminary restoration at this time because R.E Gas and Development will be three more wells on the pad during 2017. Identification signs were posted at the access road entrance, the well, and the storage tanks. The #5H well is in production. The well is equipped with a plunger lift assembly. The production tanks are surrounded by a steel dike. The pad is surrounded by a fence and all man doors were locked.

The equipment on the pad consists of the following: 9 - 400 bbl production tanks, three labelled as containing produced water, and six labelled as containing condensate. 1 Low pressure vertical separator 3 Producing wells 3 Sand separators 3 Gas processing units 1 Heat Treater 1 Vapor Recovery Unit

No violations were noted at the time of inspection.

0823637601 2017-07-19 Production Wells No Violations I conducted a status check of the well. The well is in production and Sidewinder #62 was on site drilling the #1H well. A surface-intermediate annular gauge had been installed on the well and the gauge displayed zero psi. No violations were noted at the time of inspection.
0963617495 2018-10-29 Production Wells No Violations No changes have been made to the production equipment since my last inspection. I performed a walk-around inspection of the pad and erosional controls appeared in place and functioning. The well was equipped with an open-flow assembly. The surface/intermediate annular gauge displayed a reading of zero psi, and the intermediate/production displayed approximately 1050 psi. I spoke to production personnel on site in regards to the intermediate/production annular pressure, who stated they will blow the well in an attempt to lower the annular pressure.
1394978230 2014-03-16 Drill / Deepen / Reopen No Violations I was on site to witness the cementing of the 13 3/8 inch surface casing. My inspection revealed that Sidewinder Drilling Rig # 63 has drilled a 17 1/2 inch hole to a total depth of 901 feet and ran 888 feet of 13 3/8 inch surface casing (54.5 pounds per foot / inside diameter is 12.615 inches). They installed 7 bowspring centralizers on the casing string on joints 1,2,6,10,14,18, and 20. Universal cemented the casing with 791 sacks of Type 1 3% CaCl, 0.2% foam check, and 1/4 pound per sack celloflake. The cement had a density of 15.6 pounds per gallon, a yield of 1.2 cubic feet per sack, and they used 5.2 gallons of mix water per sack. Universal pumped 169 barrels of cement slurry, 129 barrels of displacement, and the was 50 barrels of cement returns to surface. They bumped the plug with 547 PSI and then conducted the casing test with 1047 PSI. The casing test was approved, pressure released, floats held, and there was approximately 1 barrel of water flowed back. My inspection revealed no violations at this time.
1497902633 2017-06-08 Production Wells No Violations I conducted a status check of the site while HAD drilling was setting conductor pipe on the #1H, 2H, & 7H wells. I reviewed the site location according to the simultaneous operations plan submitted by Rex Energy. Sidewinder #62 was anticipated to move on site during the week of 06/12/2017. Cement barricades were in place as per the simultaneous operations plan to isolate all production equipment from drilling operations. I spoke to Andrew Campolongo, field coordinator for Rex, who informed me that the three western condensate tanks had been emptied as per the simultaneous operations plan. No violations were noted at the time of inspection.
1498088929 2017-06-19 Production Wells No Violations I conducted a status check of the well while on location for the surface casing cement job on the Jenkins #7H well. The well is in production. Barricades were installed around the production area, with additional barricades around the well head. I did not locate a surface annular pressure gauge on the well. I will contact Rex Energy to have one installed.
1768681298 2018-12-28 Production Wells Violations Noted I was on site for a status check with DOGRM inspector John Fleming and Regional Supervisor Tom Hill. The well was equipped with a plunger-lift assembly. The surface/intermediate annular gauge displayed a reading of zero psi. Identification posted at the access and well did not list the current owner of PennEnergy Resources. Records indicate that ownership of the well was transferred from R.E. Gas Development LLC to PennEnergy Resources on 10/03/2018. Per OAC: 9-9-05, any changes of ownership shall be shown on posted identification no later than sixty days after the date of transfer. The owner shall posted current identification to well and tank battery by 01/14/2019.
1808813381 2017-07-17 Production Wells No Violations I conducted a status check of the well while on location to witness the #7H surface cement job. The well is in production, but I did not locate a surface-intermediate annular pressure gauge after my request to Rex Energy to install one. I spoke to Larry Barr, production operator on site and asked a gauge to be installed. He informed me that he will install a gauge by 07/19/2017
475395915 2017-6-21 0:00: PW No Violations
660583427 2020-4-2 0:00:0 PL No Violations 1.00
769738907 2017-5-17 0:00: PW No Violations
963617495 2018-10-29 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1768681298 US-OH-117607 2019-02-27 9-9-05(A)10 Failure to legibly identify well

For data sources see[7]