34-019-21958

Well Details

Well ID: 34-019-21958
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Brown Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: SNYDER HENRY UNIT
License Status: Producing
License Date: 2005-02-03
Spud Date: 2005-03-29
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2005-04-03
Well Total Depth: 5431.00 ft
Configuration: Vertical
Latitude: 40.710000
Longitude: -81.130000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-02-03 Proposed Formations:CLINTON, Issued Date:2/3/2005, Expired Date:2/3/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-03-29 RBDMS Rec
Completed 2005-04-03 RBDMS Rec
Reached Total Depth 2005-04-03 RBDMS Rec
Completion Report Received 2005-05-04 RBDMS Rec
Construction Permit Expires 2006-02-03 RBDMS Rec
Change of Owner 2010-04-08 Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-06-30 5180 5304 39
5180 5304 39
5180 5304 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 3724 Bbl 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 RANGE RESOURCES-APPALACHIA LLC 3203.00 954.00 245
2006 RANGE RESOURCES-APPALACHIA LLC 2927.00 441.00 365
2007 RANGE RESOURCES-APPALACHIA LLC 2241.00 538.00 365
2008 RANGE RESOURCES-APPALACHIA LLC 1946.00 432.00 365
2009 RANGE RESOURCES-APPALACHIA LLC 1474.00 334.00 365
2010 ENERVEST OPERATING LLC 1293.00 337.00 365
2011 ENERVEST OPERATING LLC 1206.00 290.00 0
2012 ENERVEST OPERATING LLC 1183.00 238.00 366
2013 ENERVEST OPERATING LLC 1078.00 218.00 365
2014 ENERVEST OPERATING LLC 1139.00 220.00 365
2015 ENERVEST OPERATING LLC 970.00 258.00 365
2016 ENERVEST OPERATING LLC 841.00 155.00 366
2017 ENERVEST OPERATING LLC 767.00 217.00 365
2018 ENERVEST OPERATING LLC 184.00 259.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 RANGE RESOURCES-APPALACHIA LLC Brine 1785 245
2006 RANGE RESOURCES-APPALACHIA LLC Brine 490 365
2007 RANGE RESOURCES-APPALACHIA LLC Brine 170 365
2008 RANGE RESOURCES-APPALACHIA LLC Brine 315 365
2009 RANGE RESOURCES-APPALACHIA LLC Brine 210 365
2010 ENERVEST OPERATING LLC Brine 114 365
2011 ENERVEST OPERATING LLC Brine 127
2012 ENERVEST OPERATING LLC Brine 0 366
2013 ENERVEST OPERATING LLC Brine 182 365
2014 ENERVEST OPERATING LLC Brine 42 365
2015 ENERVEST OPERATING LLC Brine 85 365
2016 ENERVEST OPERATING LLC Brine 72 366
2017 ENERVEST OPERATING LLC Brine 74 365
2018 ENERVEST OPERATING LLC Brine 93 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-14201943 2005-3-29 0:00: DD No Violations 2.00
-1620322545 2017-6-12 0:00: PW No Violations
-1999695997 2005-6-28 0:00: PL No Violations 1.00
0014201943 2005-03-29 Drill / Deepen / Reopen No Violations On site to witness the digging of the drilling pits because the permit is marked floodplain / no earthen pits . No water encountered while digging the pits . No violations at this time .
0168781182 2017-10-11 Production Wells No Violations The well is equipped with a pumping unit. No changes have been made to the well or equipment at the tank battery since my last inspection. Proper identification was posted. The dike surrounding the tank battery contained a drain consisting of a 1.5 steel line which appeared to be open and did not contain a plug or valve. I contacted Kyle Fink, foreman at Enervest on 10/12/2017 and requested that a plug or valve be installed on the dike drain, or the drain be removed.
0203754867 2011-12-06 Production Wells No Violations This well is in production and no violations were noted at this time.
0267789506 2017-10-11 Production Wells No Violations The well is equipped with an electrically-
1112695493 2005-04-04 Drill / Deepen / Reopen No Violations Inspection revealed that Capstar Drilling has TDed the well and are running 4 1/2 casing . No violations at this time . The rig crew advised that their next location is suppose to be on Blade Rd. near the gravel pit .
1620322545 2017-06-12 Production Wells No Violations I was on site as a follow-up to complaint #5198 after my request to Enervest on 5/31/2017 to repair the lease road on the property to prevent erosional sedimentation into the adjacent field. The lease road section used as the landowners driveway had been repaired, but not the section from the tank battery to the well. I contacted Bob Whaley from Enervest on 06/12/2017 to have the affected section repaired.
168781182 2017-10-11 0:00 PW No Violations 0.70
1782783152 2018-04-11 Production Wells No Violations The well was equipped with a pumping unit and no violations were observed at the time of inspection.
1999695997 2005-06-28 Preliminary Restoration No Violations Inspection revealed that the preliminary restoration can be approved at this time . No violations at this time . The GPS readings for the wellhead are N40 42. 790 and W081 08. 073 . The GPS readings for the tank battery are N40 42. 644 and W081 08. 076 . The tank battery consists of one 210 bbl oil storage tank and an above ground plastic brine storage tank.
203754867 2011-12-6 0:00: PW No Violations 0.50
2140254100 2005-04-13 Preliminary Restoration No Violations On site to witness the solidification of the drilling pits because the drilling permit was marked floodplain ( no earthen pits ) and I had advised the operator that they could use earthen pits if they solidified the drilling pits after the drilling rig moved off location . The used two truck loads of solidification material to solidify the drilling pits .
267789506 2017-10-11 0:00 PW No Violations 0.50

For data sources see[9]

References