X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-019-21910

Well Details

Well ID: 34-019-21910
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Brown Township
Operator Name: WILLIAM S MILLER INC
Well Pad ID:
Farm/Lease Name: GEIGER
License Status: Producing
License Date: 2001-06-25
Spud Date: 2002-05-11
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2002-05-17
Well Total Depth: 5317.00 ft
Configuration: Vertical
Latitude: 40.700000
Longitude: -81.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2001-06-25 146 FOLTZ & FOLTZ ENTP Proposed Formation CLINTON Issued Date 6/25/01 Expired Date 6/25/02 6:00:00 AM
Original Spud 2002-05-11 Good cement returns ; app. 13 bbls.
Completed 2002-05-17 Good cement returns ; app. 13 bbls.
Reached Total Depth 2002-05-17 Good cement returns ; app. 13 bbls.
Construction Permit Expires 2002-06-25 Good cement returns ; app. 13 bbls.
Completion Report Received 2002-09-23 Good cement returns ; app. 13 bbls.
Correction to Well 2003-05-09 UNIT SIZE INCREASED TO 75.306 ACRES.
Change of Owner 2017-12-20 Operator changed from 146, FOLTZ & FOLTZ LTD PARTNERSHIP to 2512, WILLIAM S MILLER INC
Record Last Modified 2017-12-20 Good cement returns ; app. 13 bbls.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2002-10-31 5096 5210 28
5096 5210 28
5096 5210 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 3500 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2002 FOLTZ & FOLTZ LTD PARTNERSHIP 927.00 3497.00 166
2003 FOLTZ & FOLTZ LTD PARTNERSHIP 10765.00 3697.00 166
2004 FOLTZ & FOLTZ LTD PARTNERSHIP 15340.00 14753.00 166
2005 FOLTZ & FOLTZ LTD PARTNERSHIP 4328.00 2076.00 365
2006 FOLTZ & FOLTZ LTD PARTNERSHIP 3885.00 1656.00 365
2007 FOLTZ & FOLTZ LTD PARTNERSHIP 1759.00 875.00 365
2008 FOLTZ & FOLTZ LTD PARTNERSHIP 2241.00 1564.00 365
2009 FOLTZ & FOLTZ LTD PARTNERSHIP 1841.00 915.00 365
2011 FOLTZ & FOLTZ LTD PARTNERSHIP 1794.00 916.00 365
2012 FOLTZ & FOLTZ LTD PARTNERSHIP 919.00 336.00 366
2013 FOLTZ & FOLTZ LTD PARTNERSHIP 1378.00 1239.00 365
2014 FOLTZ & FOLTZ LTD PARTNERSHIP 3448.00 568.00 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP 715.00 400.00 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP 1193.00 414.00 365
2017 WILLIAM S MILLER INC 2398.00 0.00 0
2018 WILLIAM S MILLER INC 2404.00 1519.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2002 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 3015 166
2003 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 2020 166
2004 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 1542 166
2005 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 194 365
2006 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2007 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 159 365
2008 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 120 365
2009 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 80 365
2011 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 200 365
2012 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 31 366
2013 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 221 365
2014 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 100 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 35 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 75 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 160 365
2018 WILLIAM S MILLER INC Brine 739 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1230162831 2016-6-14 0:00: PW No Violations
1230162831 2016-06-14 Production Wells No Violations I conducted a status check of this well. The well is equipped with an electrically-driven pumpjack. The production valves were in the open position. The tank battery shares production equipment with PN#1933 and consists of two 200 bbl production tanks, one 50 bbl brine tank, and one vertical separator with a drip bottle. I could not locate the meter un. The tank battery is surrounded by a dike. The tanks production valves were equipped with locks and plugs. The lease road was stable and drivable. No identification was posted at the well or tank battery. I contacted the operator on 06/16/2016. They will have proper identification posted. I will follow up during the week of 06/27/2016.
1325601977 2012-01-03 Preliminary Restoration No Violations Preliminary Restoration can be passed. There is no production reported for 2010 and no violations are noted at this time.
1325684792 2012-01-03 Preliminary Restoration No Violations Inspection revealed that the Preliminary Retoration can be passed at this time. Well has no reported production for 2010. No violations are noted at this time.

For data sources see[9]

References