X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-019-21412

Well Details

Well ID: 34-019-21412
Loading map...
Country: United States
State: Ohio
County: Carroll
Municipality: Brown Township
Operator Name: PETROX, INC
Well Pad ID:
Farm/Lease Name: WADSWORTH A & G WELL
License Status: Producing
License Date: 1981-03-06
Spud Date: 1981-04-14
Spud Drilling Contractor:
Final Drill Date: 1981-04-19
Well Total Depth: 5536.00 ft
Configuration: Vertical
Latitude: 40.660000
Longitude: -81.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-03-06 182 BELDEN & BLAKE CO GeoDate 3/6/81
Original Spud 1981-04-14
Completed 1981-04-19
Reached Total Depth 1981-04-19
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
Change of Owner 2013-12-12 Operator changed from 7578, ENERVEST OPERATING L to 1966, PETROX, INC
Record Last Modified 2013-12-12

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5352 5404 18
5352 5404 18
5352 5404 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 0
H2O 0 77600 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION 639.00 679.00 0
1985 BELDEN & BLAKE CORPORATION 1186.00 479.00 0
1986 BELDEN & BLAKE CORPORATION 708.00 383.00 365
1987 BELDEN & BLAKE CORPORATION 1199.00 326.00 365
1988 BELDEN & BLAKE CORPORATION 172.00 325.00 337
1990 BELDEN & BLAKE CORPORATION 522.00 345.00 356
1991 BELDEN & BLAKE CORPORATION 525.00 265.00 365
1992 BELDEN & BLAKE CORPORATION 224.00 316.00 366
1993 BELDEN & BLAKE CORPORATION 230.00 158.00 365
1994 BELDEN & BLAKE CORPORATION 409.00 312.00 358
1995 BELDEN & BLAKE CORPORATION 504.00 159.00 365
1996 BELDEN & BLAKE CORPORATION 376.00 320.00 366
1997 BELDEN & BLAKE CORPORATION 653.00 159.00 358
1998 BELDEN & BLAKE CORPORATION 631.00 90.00 252
1999 BELDEN & BLAKE CORPORATION 279.00 278.00 184
2000 BELDEN & BLAKE CORPORATION 173.00 300.00 359
2001 BELDEN & BLAKE CORPORATION 185.00 170.00 365
2002 BELDEN & BLAKE CORPORATION 142.00 126.00 212
2003 PETROX, INC 455.00 160.00 365
2004 PETROX, INC 545.00 188.00 365
2005 PETROX, INC 635.00 164.00 365
2006 PETROX, INC 329.00 133.00 337
2007 PETROX, INC 725.00 156.00 365
2008 PETROX, INC 230.00 142.00 365
2009 PETROX, INC 324.00 165.00 365
2010 PETROX, INC 277.00 111.00 365
2011 PETROX, INC 363.00 91.00 365
2012 PETROX, INC 251.00 105.00 366
2013 PETROX, INC 422.00 171.00 365
2014 PETROX, INC 286.00 43.00 365
2015 PETROX, INC 420.00 103.00 365
2016 PETROX, INC 555.00 169.00 365
2017 PETROX, INC 406.00 83.00 365
2018 PETROX, INC 405.00 92.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 BELDEN & BLAKE CORPORATION Brine 0 0
1985 BELDEN & BLAKE CORPORATION Brine 229 0
1986 BELDEN & BLAKE CORPORATION Brine 193 365
1987 BELDEN & BLAKE CORPORATION Brine 196 365
1988 BELDEN & BLAKE CORPORATION Brine 137 337
1990 BELDEN & BLAKE CORPORATION Brine 136 356
1991 BELDEN & BLAKE CORPORATION Brine 120 365
1992 BELDEN & BLAKE CORPORATION Brine 128 366
1993 BELDEN & BLAKE CORPORATION Brine 126 365
1994 BELDEN & BLAKE CORPORATION Brine 172 358
1995 BELDEN & BLAKE CORPORATION Brine 117 365
1996 BELDEN & BLAKE CORPORATION Brine 122 366
1997 BELDEN & BLAKE CORPORATION Brine 68 358
1998 BELDEN & BLAKE CORPORATION Brine 55 252
1999 BELDEN & BLAKE CORPORATION Brine 205 184
2000 BELDEN & BLAKE CORPORATION Brine 141 359
2001 BELDEN & BLAKE CORPORATION Brine 129 365
2002 BELDEN & BLAKE CORPORATION Brine 74 212
2003 PETROX, INC Brine 162 365
2004 PETROX, INC Brine 160 365
2005 PETROX, INC Brine 140 365
2006 PETROX, INC Brine 218 337
2007 PETROX, INC Brine 365
2008 PETROX, INC Brine 75 365
2009 PETROX, INC Brine 145 365
2010 PETROX, INC Brine 142 365
2011 PETROX, INC Brine 150 365
2012 PETROX, INC Brine 185 366
2013 PETROX, INC Brine 122 365
2014 PETROX, INC Brine 150 365
2015 PETROX, INC Brine 170 365
2016 PETROX, INC Brine 195 365
2017 PETROX, INC Brine 235 365
2018 PETROX, INC Brine 180 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1459526544 2002-12-31 0:00 PW No Violations 0.50
-1619936115 2002-12-31 0:00 PW No Violations 0.50
-1680708827 2017-11-21 0:00 PW No Violations 0.50
1039178304 2018-10-15 Production Wells No Violations The well was equipped with a pumping unit. No violations were observed at the time of inspection.
1335294889 2012-04-24 Production Wells No Violations My inspection revealed the well is producing and no violations were noted at this time at the well head or tank battery.
1459526544 2002-12-31 Production Wells No Violations Routine inspection revealed no violations at this time . There has been a change of ownership from Belden & Blake to Petrox . The new owner Identification has been posted .
1619936115 2002-12-31 Production Wells No Violations Routine inspection revealed no violations at this time . There has been a change of ownership from Belden & Blake to Petrox . The new owner Identification has been posted .
1680708827 2017-11-21 Production Wells No Violations The well is equipped with an electrically-driven pumping unit. No violations were observed at the time of inspection.
1965766434 2016-09-17 Production Wells No Violations I conducted a status check of this well. The well is equipped with an electrically-driven pumpjack. The production valves were in the open position. The tank battery consists of one 210 bbl production tank, one underground cement brine vault, one vertical separator, and one meter run with a current 31-day chart. The load line to the tanks production valve was equipped with a lock and plug. The tank battery was surrounded by a dike. Identification was posted at the well and tank battery.

For data sources see[9]

References