X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-013-21321

Well Details

Well ID: 34-013-21321
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Mead Township
Operator Name: XTO ENERGY INC.
Well Pad ID: US-OH-001341
Farm/Lease Name: KRNYAICH UNIT B
License Status: Cancelled
License Date: 2018-01-11
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Horizontal
Latitude: 39.960000
Longitude: -80.840000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2018-01-11 Proposed Formations:POINT PLEASANT, Issued Date:1/11/2018, Expired Date:1/11/2020 12:00:00 PM, Drilling unit acres:638.828, Proposed Well Type:OG, Proposed Well Class:POOL
Record Last Modified 2018-09-12
Construction Permit Expires 2020-01-11

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1438730513 2018-8-7 0:00:0 DD No Violations 0.20
-417370625 2018-8-15 0:00: DD No Violations 0.50
-821273161 2018-8-23 0:00: DD No Violations 1.00
0417370625 2018-08-15 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that the 30-
0821273161 2018-08-23 Drill / Deepen / Reopen No Violations On the day of my inspection I witnessed that Appalachian Drilling was currently conditioning the well bore at 532 feet depth. After speaking with company man Steve Guile, he informed me that they encountered a mine void from 470 feet to 476 feet depth and had to switch from a 24-inch diameter percussion bit to a 24-inch diameter Tri-Cone bit. Steve also informed me that they intend on running 542 feet of 87.5 pound per foot J-55 casing with a cement basket at 441 feet depth and cement to surface. I informed Steve that he needed to send me a cement report, and pipe tally and upon completion of pumping cement they are required to wait until cement reaches a compressive strength of 500 pounds per square inch before any further action can be taken.
1438730513 2018-08-07 Drill / Deepen / Reopen No Violations

For data sources see[3]