If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-21213 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.01,"lon":-81.07,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Goshen Township | |
Operator Name: RICE DRILLING D LLC | |
Well Pad ID: US-OH-001517 | |
Farm/Lease Name: DEL SCORCHO | |
License Status: Producing | |
License Date: 2017-11-09 | |
Spud Date: 2018-05-14 | |
Spud Drilling Contractor: H&P DRILLING | |
Final Drill Date: 2018-08-22 | |
Well Total Depth: 20496.00 ft | |
Configuration: Horizontal | |
Latitude: 40.010000 | |
Longitude: -81.070000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2017-03-27 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:3/27/2017, Expired Date:3/27/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
APP | 2017-11-09 | Proposed Formations:UTICA/POINT PLEASANT, Issued Date:11/9/2017, Expired Date:11/9/2019 12:00:00 PM, Drilling unit acres:459.6504, Proposed Well Type:OG, Proposed Well Class:POOL |
Correction to Well | 2018-05-09 | UPDATE TARGET/TAKE AS-DRILLED PLAT |
Correction to Well | 2018-06-22 | CHANGE TO TARGET AND TAKE-POINT INFORMATION. |
Reached Total Depth | 2018-08-22 | |
Record Last Modified | 2018-11-05 | |
Construction Permit Expires | 2019-11-09 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
20357 | 20408 | 0 | |
9153 | 9334 | 0 | |
9153 | 9334 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1273022195 | 2018-12-20 0:00 | CT | No Violations | 0.20 |
-1297704182 | 2020-5-7 0:00:0 | PW | No Violations | 0.20 |
0176771517 | 2019-03-04 | Completion Testing | No Violations | Status check inspection found 6 wells present on the pad. The said well has been drilled and not completed. The well is equipped with a night cap with a manual gate valve on the night cap. There is a gauge on the valve but the valve is closed. No annular pressure monitoring is present on the A or B section. The Del Scorcho # 8 #10 and #12 wells have been drilled but are not completed. The number 2 #4 and # 6 wells are in the flow back production stages and are not equipped with annular pressure monitoring either. There is a large above ground storage tank on location. The well pad perimeter does have a sound wall erected on top of the earthen berm. A third party midstream pipe line was installed ant the earthen berm was removed and not properly put back. I did notify ODNR Engineer Technician Anthony Carson on this day of the deficiency related to the berm. |
1121462675 | 2020-1-16 0:00: | PW | No Violations | 0.30 |
1273022195 | 2018-12-20 | Completion Testing | No Violations | Status check inspection found the well drilling process complete and the well equipped with a night cap on the B section. The well has not been stimulated. 6 wells are present on the pad that have been drilled and only (2) are in production. |
1423236168 | 2019-06-04 | Completion Testing | No Violations | On the day of my inspection I witnessed Halliburton Pressure Pumping, Schlumberger wireline were currently on location and had just completed the 17th stage of the stimulation process out of a total of 57 total stages. At the time of my inspection the stimulation process was currently shut down due to a wireline failure at surface. Annular pressures were being monitored on every well on the pad. After speaking with EQT consultant Brad Wolff he informed me that they had a Schlumberger wireline failure at surface, they intend to switch out the Schlumberger wireline truck and tool. I informed EQT consultant Brad Wolff to keep me updated with any problems or situations that occur during the stimulation process. |
1462932177 | 2018-05-17 | Casing String Witnessed | No Violations | On the day of my inspection I witnessed that H&P 471 had drilled the 24 inch diameter hole to a depth of 404 feet. Wyoming Casing Crew ran 369 feet of 18.625 inch diameter J 55 casing at 87.5 pound per foot, with 5.1 feet of casing above KB. BJ Services was on site and rigged up their cement head, loaded lines with 5 barrels of fresh water and pressure tested to 2500 pounds per square inch. BJ Services broke circulation with 167 barrels of fresh water, pumped a 35 barrel gel spacer, and 10 barrels of fresh water spacer, and 142 barrels of 15.6 pounds per gallon with a yield of 1.20 cubic feet per sack Class A cement mixed with 5.25 gallons of water per sack. Cement was displaced with 98 barrels of fresh water and had 16 barrels of good cement returns to surface. Plug was bumped at 150 pounds per square inch and pressured up to 650 pounds per square inch and held for 5 minutes, floats held with 1 barrel of flow back. |
1526919184 | 2018-05-16 | Drill / Deepen / Reopen | No Violations | |
1593613064 | 2020-7-1 0:00:0 | PW | No Violations | 0.50 |
176771517 | 2019-3-4 0:00:0 | CT | No Violations | 0.20 |
424924492 | 2019-7-11 0:00: | CT | No Violations | 0.50 |
For data sources see[4]