X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-013-21116

Well Details

Well ID: 34-013-21116
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: York Township
Operator Name: RICE DRILLING D LLC
Well Pad ID: US-OH-001453
Farm/Lease Name: DREAMWEAVER
License Status: Producing
License Date: 2017-04-03
Spud Date: 2017-08-16
Spud Drilling Contractor: H&P DRILLING
Final Drill Date: 2018-01-14
Well Total Depth: 23008.00 ft
Configuration: Horizontal
Latitude: 39.920000
Longitude: -80.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2016-10-31 Proposed Formations:UTICA THRU POINT PLEASANT, Issued Date:10/31/2016, Expired Date:10/31/2017 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2017-04-03 Proposed Formations:UTICA/POINT PLEASANT, Issued Date:4/3/2017, Expired Date:4/3/2019 12:00:00 PM, Drilling unit acres:367.316, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2017-06-30 CHANGE TO UNIT SIZE AND TARGET INFORMATION FROM REVISED PLAT.
Reached Total Depth 2018-01-14
Correction to Well 2018-03-30 CORRECTION TO TARGET AND TAKE-POINT INFORMATION FROM AS DRILLED SURVEY PLAT.
Completion Report Received 2018-11-15
Record Last Modified 2018-11-20
Construction Permit Expires 2019-04-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-11-19 10463 10645 0
2018-11-19 22863 22865 0
22863 22865 0
10463 10645 0
10463 10645 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 06/23/2018 08/06/2018 10125.4 26,448,300.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Lubricating oils (petroleum), C20-50,

hydrotreated neutral oil-based

72623-87-1 45 0.000339521 879.029
Trade Secret Proprietary 1 0.00000754 19.534
Ethylene Glycol 107-21-1 30 0.00006318 163.579
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00378895 9809.69
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0227337 58858.2
Sodium hypochlorite 7681-52-9 16 0.00251049 6499.71
Trade Secret Proprietary 5 0.00003772 97.67
Alcohols, C11-14-iso-, C13-rich, ethoxylated 78330-21-9 5 0.00378895 9809.69
Trade Secret Proprietary 15 0.000113174 293.01
Phosphonic Acid, {Dimethylamino) Methylene} Bis - 29712-30-9 5 0.00116462 3015.24
Phosphonic Acid, {Nitrilotris (methylene)} Tris 6419-19-8 35 0.00815236 21106.7
Phosphonic Acid, {Dimethylamino) Methylene} Bis - 29712-30-9 5 0.00116462 3015.24
Aromatic aldehyde Proprietary 10 0.00002106 54.526
Phosphorous Acid 10294-56-1 2 0.000465849 1206.1
Sodium hydroxide 1310-73-2 5 0.000784527 2031.16
Dimethylformamide 68-12-2 10 0.00002106 54.526
Trade Secret Proprietary 40 0.000301797 781.359
Isopropanol 67-63-0 30 0.00006318 163.579
Distillates (petroleum), hydrotreated light 64742-47-8 30 0.0227337 58858.2
Trade Secret Proprietary 5 0.00003772 97.67
Phosphonic Acid, {Nitrilotris (methylene)} Tris 6419-19-8 35 0.00815236 21106.7
Phosphorous Acid 10294-56-1 2 0.000465849 1206.1
Lubricating oils (petroleum), C20-50,

hydrotreated neutral oil-based

72623-87-1 45 0.000339521 879.029
Sodium hypochlorite 7681-52-9 16 0.00251049 6499.71
Trade Secret Proprietary 1 0.00000754 19.534
Quaternary ammonium compound Proprietary 10 0.00002106 54.526
Silica Substrate 14808-60-7 100 14.5101 37,567,100.0
Organic amine resin salt Proprietary 30 0.00006318 163.579
Trade Secret Proprietary 40 0.000301797 781.359
Trade Secret Proprietary 15 0.000113174 293.01
Hydrochloric Acid 7647-01-0 15 0.0188274 48744.6
Sodium hydroxide 1310-73-2 5 0.000784527 2031.16
Ethylene Glycol 107-21-1 30 0.00006318 163.579
Sand (Proppant) FTS International Proppant Listed Below
Hydrochloric Acid FTS International Acidizing Listed Below
CS-1000 SI FTS International Scale inhibitor Listed Below
Silver 7500 P.O.P. Silverback Chemical Polymer Water 7732-18-5 89.7 0.0140744 36439
Water 7732-18-5 15 0.000113174 293.01
FRW-1450 FTS International Friction reducer Listed Below
CI-150 FTS International Acid Corrosion Inhibitor Listed Below
Water FTS International Carrier/Base Fluid Water 7732-18-5 100 85.2486 220,711,000.0
Other Chemical(s) Listed Above See Trade Name(s) List Water 7732-18-5 89.7 0.0140744 36439
Water 7732-18-5 15 0.000113174 293.01
Sodium Hypochlorite Dirk Thomas Solutions Biocide Listed Below

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2018-08-05 H2O 15 8794 Bbl 604683 Frac Tech Services STAGE 63/63

STAGES 2-62 SEE IMAGES

2018-05-07 H2O 15 5438 Bbl 240099 Frac Tech Services STAGE 1/63

STAGES 2-62 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 RICE DRILLING D LLC 2071141 0 107
2019 RICE DRILLING D LLC 1872036 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 RICE DRILLING D LLC Brine 78593 107
2019 RICE DRILLING D LLC Brine 41383 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-189424533 2017-8-17 0:00: CS No Violations 3.00
-401191069 2020-4-2 0:00:0 PL No Violations 0.20
-787433841 2018-1-12 0:00: DD No Violations 1.00
0189424533 2017-08-17 Casing String Witnessed No Violations On the day of my inspection I witnessed Express energy had augured a 36 inch diameter hole to 100 feet. 100 feet of 30 inch diameter conductor casing was run. Express energy was onsite with 275 sacks of class A cement. Additives include 2% CaCl and .5 lb./sack cello-flake. Cement weighed with mudscale at 15.6 ppg and yield of 1.2. 50 percent excess ran. Cement was displaced with 74.8 barrels of fresh water. 18 barrels of cement returned to surface. No water encountered during drilling.
0787433841 2018-01-12 Drill / Deepen / Reopen No Violations On the day of my inspection I found H&P 471 had drilled an 8.5 inch diameter hole to a total depth of 23008. Franks was onsite running 5.5 inch diameter production casing weighing 20 pounds per foot. Casing will land at 22990 feet. Company man Pat Smith is anticipating cementing the production string tonight.
1458299219 2019-01-09 Production Wells No Violations Status check inspection found 4 wells present on the pad and in production. All 4 wells are producing off the 5.5 diameter production casing through 2 primary master valves with an additional emergency shut down valve in line. The wells are selling through 3rd party choke manifolds and sand trap separators. A separate facility is present with 4 steel 500 barrel tanks set inside polymer containment, these tanks are being used for the sand trap separators to be evacuated into. No riser pipes or gauges are present on the well head A&B sections to allow for annular pressure monitoring. Additional production equipment includes 4 gas processing units along with a production facility consisting of (4) steel tanks capable of holding 500 barrels fluid volume each. There is an additional horizontal 100 barrel tank inside the tank battery. All tanks are situated inside a polymer lined steel containment dike area.
1514577648 2017-12-29 Drill / Deepen / Reopen No Violations On the day of my inspection I witness HP 471 rig tripping out of the hole at 9416 feet. The measurement while drilling (MWD) tool failed and they are tripping out to repair/replace it. Company man Ron said that they spilled approximately 25 gallons of oil base drilling fluid and that he reported it to EQT so that they could report the spill. I am not sure whether it was reported to us but I never received a call. The spill was on containment and cleaned up. They have not been able to steam clean the area with the cold weather but plan to as soon as the temperature is conducive to do so.

For data sources see[10]

References