If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-013-20665 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.89,"lon":-81.17,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Belmont | |
Municipality: Somerset Township | |
Operator Name: GULFPORT ENERGY CORPORATION | |
Well Pad ID: US-OH-000532 | |
Farm/Lease Name: STUTZMAN | |
License Status: Final Restoration | |
License Date: 2012-07-06 | |
Spud Date: 2012-08-23 | |
Spud Drilling Contractor: H A D INC | |
Final Drill Date: 2012-08-24 | |
Well Total Depth: 65.00 ft | |
Configuration: Vertical | |
Latitude: 39.890000 | |
Longitude: -81.170000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-07-06 | Proposed Formations:TRENTON, Issued Date:7/6/2012, Expired Date:7/6/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Reached Total Depth | 2012-08-24 | |
Plugged/Abandoned | 2012-08-25 | |
Construction Permit Expires | 2014-07-06 | |
Record Last Modified | 2017-05-31 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2015-07-06 | 9180 | 17156 | 0 |
9180 | 17156 | 0 | |
9180 | 17156 | 0 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 11/24/2012 | 01/09/2013 | 9020 | 9,589,650.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | 100 mesh | Minerva/Cadiz | Proppant | Sand | 14808-60-7 | 100 | 1.70165 | 0 |
Entegrate SC8060 WB | U.S. Water | Scale Inhibitor | 2-propenoic acid, sodium salt, polymer | 37350-42-8 | 10 | 0.00112 | 0 | |
Water | 7732-18-5 | 59 | 0.00663 | 0 | ||||
Phosphoric Acid | 7664-38-2 | 1 | 0.00011 | 0 | ||||
Methyl Alcohol | 67-56-1 | 20 | 0.00225 | 0 | ||||
Aminotrimethylene Phosphonic Acid | 6419-19-8 | 10 | 0.00112 | 0 | ||||
Clean Gel | Stingray | Guar Gel | heavy aliphatic | NA | 35 | 0.04801 | 0 | |
Solvent naphtha, (petroleum) | 64742-96-7 | 65 | 0.08915 | 0 | ||||
30/50 White | Minerva/Cadiz | Proppant | Sand | 14808-60-7 | 100 | 17.0165 | 0 | |
Entegrate NE 1100 | U.S. Water | Demulsifier | Water | 7732-18-5 | 60 | 0.02464 | 0 | |
Ethylene/Propylene Oxide Polymer | NA | 40 | 0.01643 | 0 | ||||
Citric Acid 50% | Pace International | Acid | citric acid | 77-92-9 | 50 | 0.42433 | 0 | |
Water | 7732-18-5 | 50 | 0.42433 | 0 | ||||
Per Break | Stingray | Breaker | Ammonium Persulfate | 7727-54-0 | 99 | 0.01131 | 0 | |
Entegrate FR 7170 | U.S. Water | Friction Reducer | Water | 7732-18-5 | 48 | 0.02762 | 0 | |
Alcohols (C12-16), ethoxylated | 68551-12-2 | 3.1 | 0.00178 | 0 | ||||
Petroleum distillate hydrotreated light | 64742-47-8 | 28 | 0.01611 | 0 | ||||
C12-C14 Alcohol ethoxylated | 68439-50-9 | 3.1 | 0.00178 | 0 | ||||
Ammonium chloride | 12125-02-9 | 15 | 0.00863 | 0 | ||||
Alcohols (C10-16), ethoxylated | 68002-97-1 | 3.1 | 0.00178 | 0 | ||||
PROCLEAN 200 | U.S. Water | Corossion Inhibitor | Water | 7732-18-5 | 48 | 0.00065 | 0 | |
Citric Acid, Food Grade | 77-92-9 | 52 | 0.0007 | 0 | ||||
Fresh water | Stingray | Carrier | Water | 7732-18-5 | 100 | 80.1034 | 0 | |
40/70 White | Minerva/Cadiz | Proppant | Sand | 14808-60-7 | 100 | 0 | 0 | |
BioClear 5000 | Weatherford | Biocide | 2,2-dibromo-3-nitril oprop ionam ide | 10222-01-2 | 5 | 0.00136 | 0 | |
Water | 7732-18-5 | 95 | 0.02575 | 0 | ||||
X-Linker | Stingray | Guar Gel | Ethylene Glycol | NA | 30 | 0.00693 | 0 | |
Water | 7732-18-5 | 70 | 0.01617 | 0 | ||||
IC-250 | Stingray | Corossion Inhibitor | Water | 7732-18-5 | 80 | 0.00545 | 0 | |
Proprietary polycarboxylic acid mixture | NA | 20 | 0.00136 | 0 | ||||
Entecide QG40 | U.S. Water | Breaker | GLUTARALDEHYDE | 111-30-8 | 27 | 0.00349 | 0 | |
n-ALKYL DIMETHYL BENZYL AMMONIUM CHLORIDE | 68424-85-1 | 5.5 | 0.00071 | 0 | ||||
DIDECYL DIMETHYL AMMONIUM CHLORIDE | 7173-51-5 | 8.3 | 0.00107 | 0 | ||||
Water | 7732-18-5 | 56.4 | 0.0073 | 0 | ||||
ETHANOL | 64-17-5 | 2.8 | 0.00036 | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-2005004618 | 2015-8-13 0:00: | PL | No Violations | 1.00 |
-418733858 | 2018-9-19 0:00: | PW | No Violations | 0.50 |
0418733858 | 2018-09-19 | Production Wells | No Violations | On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing, and 2.875-inch diameter tubing using a plunger lift system. Annular pressure monitoring was in place for the 9.625-inch diameter intermediate casing gauge read 0 pounds per square inch, and the 13.375-inch diameter casing gauge read 250 pounds per square inch. Production equipment included a Sand Separator, Gas Processing unit and four 400-barrel production fluid tanks, and a 50-barrel produced water tank shared with the other producing wells on the well pad. There were multiple Emergency Shutoff Devices on location, Identification tags were present, and production was up to date. |
1364966309 | 2017-05-11 | Final Restoration | No Violations | The final restoration for this well is complete as the well has been plugged. The restoration for the well site pad disturbance area is required to be remediated once all other wells on this pad are plugged. Final restoration passed. |
2005004618 | 2015-08-13 | Preliminary Restoration | No Violations | On the day of my inspection the well appeared to have all equipment to be considered capable of production. The tank battery contained four 400 barrel production fluid storage tanks. The site was evaluated to confirm that proper vegetation and erosion co |
For data sources see[5]