34-013-20311

Well Details

Well ID: 34-013-20311
Loading map...
Country: United States
State: Ohio
County: Belmont
Municipality: Pultney Township
Operator Name: EQUITY OIL & GAS FUNDS INC
Well Pad ID:
Farm/Lease Name: GREENLEE
License Status: Final Restoration
License Date: 2019-03-08
Spud Date: 1980-04-07
Spud Drilling Contractor: S W JACK DRLG
Final Drill Date: 1980-04-13
Well Total Depth: 2150.00 ft
Configuration: Vertical
Latitude: 40.040000
Longitude: -80.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-12-13 508 M C F OIL CO INC GeoDate 12/13/79
Original Spud 1980-04-07
Completed 1980-04-13
Reached Total Depth 1980-04-13
Completion Report Received 1980-05-12
CO 1994-10-26 2512 MILLER WILLIAM S INC GeoDate 12/13/79
Change of Owner 1998-12-15 Operator changed from 2512, MILLER WILLIAM S INC to 5429, MILEY GAS COMPANY
Change of Owner 2005-09-19 Operator changed from 5429, MILEY GAS COMPANY to 1171, EQUITY OIL & GAS FUNDS IN
APP 2019-03-08 Proposed Formations:BEREA, Issued Date:3/8/2019, Expired Date:3/7/2021 12:00:00 PM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2019-03-15
Construction Permit Expires 2021-03-07

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-09-20 1236 1258 13
2001-09-20 1958 1976 18
1236 1258 13
1958 1976 18
1236 1258 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 20470 Gal 24500
H2O 0 19000 Gal 24500

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2083954553 2018-10-31 0:00 PW No Violations 1.50
0942040096 2018-10-31 Production Wells No Violations Accompanied ODNR inspector Bill Stolarik, please reference his report for further details.
1138387442 2006-01-27 Production Wells No Violations STATUS CHECK, REWORKING WELLS.
1568053405 2019-9-9 0:00:0 PW No Violations 0.80
1568646278 2019-9-16 0:00: PB No Violations 4.50
1568733556 2019-9-17 0:00: PB No Violations 1.50
1569358842 2019-9-24 0:00: PB No Violations 1.50
1569429558 2019-9-25 0:00: PB No Violations 6.00
1569503266 2019-9-26 0:00: PB No Violations 6.00
1630341256 2007-01-31 Production Wells No Violations STATUS CHECK WITH JOHN MURPHY
2083954553 2018-10-31 Production Wells Violations Noted On 10/31/2018 I conducted an inspection of the well accompanied by ODNR Inspector Ryan Armstrong. The well was observed to be equipped above ground level with a 8.625 diameter casing well head followed by a 4.5 diameter casing string and a 1.900 diameter tubing string. There was a polish rod liner and pumping rods inserted into the tubing well head. Attached to the surface casing well head was (2) steel flow lines with production valves present, the valve stems were rusted and deteriorated to the point that the valve positions could not be confirmed. The 4.5 diameter casing was equipped with a casing head with (2) production flow lines attached that lead into a vertical separator placed directly in front of the well head, one casing valve was partially open. The separator does not meet the proper set back distance from the well head. Inserted into the 4.5 diameter production casing head is 1.900 tubing that is equipped with (2) steel flow lines that have production valves present in the closed position. The flow lines on the outward side of the production valve are not connected. The well is set up to be produced by the means of a pumping unit with no drive motor or engine present. No domestic or commercial production means is present at the well or in the area of the well. No production facility associated with the well was found at the well or in the area. No flow lines or flow line markers were found in the area of the well. No well identification is posted. The State RBDMS records indicate the well was transferred into the current registered owners name on 09/19/2005 and no commercial production has been reported on record. Photographs were taken on this day and the well location confirmed by GPS. Also noted was the listed contact phone number in the State RBDMS database was called and a voice message left regarding the said well and other issues in the area. The well owner/operator shall submit a written plugging schedule to Inspector Bill Stolarik at 5880 Mem
215402664 2020-10-13 0:00 FR No Violations 1.50
942040096 2018-10-31 0:00 PW No Violations 0.50
iDIAN00154 1999-08-31 Final Restoration No Violations
iDIAN001548 1999-8-31 0:00: FR No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
2083954553 US-OH-121265 2018-11-07 Failure to legibly identify well
2083954553 US-OH-121266 2018-11-07 Violation of separator spacing requirements
2083954553 US-OH-121267 2018-11-07 Well shall be plugged