34-007-22542

Well Details

Well ID: 34-007-22542
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Rome Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: BRZYSCZ / HEROD
License Status: Producing
License Date: 1983-12-19
Spud Date: 1984-03-05
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1984-03-10
Well Total Depth: 3621.00 ft
Configuration: Vertical
Latitude: 41.600000
Longitude: -80.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-12-19 254 EDCO DRILLING & PRODUCING GeoDate 12/19/83
Oil and Gas 1983-12-19 Issued Date 12/19/83 Expired Date 6/16/84 Acres 0020000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 03621 Proposed Drill Depth 03621
Original Spud 1984-03-05
Completed 1984-03-10
Reached Total Depth 1984-03-10
Completion Report Received 1984-03-20
Construction Permit Expires 1984-06-16
CO 1993-10-18 1111 MERIDIAN ENERGY COMPANY GeoDate 12/19/83
Change of Owner 2015-10-15 Operator changed from 1111, MERIDIAN ENERGY COMPANY to 1333, BIG SKY ENERGY INC TRANSFERRED WELL PER CHANGE OF OWNER DATED 2/8/1999 ON 10/15/2015 CM.
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3459 3509 22
3459 3509 22
3459 3509 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 180 Mscf 0
H2O 0 18000 Bbl 50000 FRAC;H2O,SAND,N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EDCO DRILLING & PRODUCING 5087.00 1634.00 273
1986 EDCO DRILLING & PRODUCING 8519.00 2656.00 365
1987 EDCO DRILLING & PRODUCING 6990.00 1767.00 365
1988 EDCO DRILLING & PRODUCING 382.00 181.00 365
1989 EDCO DRILLING & PRODUCING 4583.00 1191.00 365
1990 EDCO DRILLING & PRODUCING 4718.00 1275.00 365
1991 EDCO DRILLING & PRODUCING 3350.00 986.00 365
1992 EDCO DRILLING & PRODUCING 3021.00 879.00 365
1993 EDCO DRILLING & PRODUCING 2617.00 486.00 200
1994 MERIDIAN ENERGY COMPANY 1909.00 502.00 365
1995 MERIDIAN ENERGY COMPANY 1070.00 170.00 365
1996 MERIDIAN ENERGY COMPANY 71.00 298.00 365
1997 MERIDIAN ENERGY COMPANY 1283.00 223.00 365
1999 MERIDIAN ENERGY COMPANY 465.00 142.00 365
2000 MERIDIAN ENERGY COMPANY 221.00 120.00 365
2001 BIG SKY ENERGY INC 1.00 0.00 365
2002 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2003 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2004 MERIDIAN ENERGY COMPANY 0.00 0.00 0
2005 MERIDIAN ENERGY COMPANY 0.00 57.00 365
2006 MERIDIAN ENERGY COMPANY 1042.00 1295.00 365
2007 MERIDIAN ENERGY COMPANY 1153.00 750.00 365
2008 MERIDIAN ENERGY COMPANY 1286.00 446.00 365
2009 MERIDIAN ENERGY COMPANY 1164.00 561.00 365
2010 MERIDIAN ENERGY COMPANY 722.00 555.00 365
2011 BIG SKY ENERGY INC 621.00 224.00 365
2012 BIG SKY ENERGY INC 593.00 276.00 366
2013 BIG SKY ENERGY INC 465.00 377.00 365
2014 BIG SKY ENERGY INC 558.00 188.00 365
2016 BIG SKY ENERGY INC 263.00 76.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EDCO DRILLING & PRODUCING Brine 218 273
1986 EDCO DRILLING & PRODUCING Brine 440 365
1987 EDCO DRILLING & PRODUCING Brine 217 365
1988 EDCO DRILLING & PRODUCING Brine 253 365
1989 EDCO DRILLING & PRODUCING Brine 246 365
1990 EDCO DRILLING & PRODUCING Brine 201 365
1991 EDCO DRILLING & PRODUCING Brine 185 365
1992 EDCO DRILLING & PRODUCING Brine 170 365
1993 EDCO DRILLING & PRODUCING Brine 57 200
1994 MERIDIAN ENERGY COMPANY Brine 85 365
1995 MERIDIAN ENERGY COMPANY Brine 0 365
1996 MERIDIAN ENERGY COMPANY Brine 133 365
1997 MERIDIAN ENERGY COMPANY Brine 0 365
1999 MERIDIAN ENERGY COMPANY Brine 29 365
2000 MERIDIAN ENERGY COMPANY Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 MERIDIAN ENERGY COMPANY Brine 0 365
2003 MERIDIAN ENERGY COMPANY Brine 0 365
2004 MERIDIAN ENERGY COMPANY Brine 0 0
2005 MERIDIAN ENERGY COMPANY Brine 0 365
2006 MERIDIAN ENERGY COMPANY Brine 0 365
2007 MERIDIAN ENERGY COMPANY Brine 0 365
2008 MERIDIAN ENERGY COMPANY Brine 0 365
2009 MERIDIAN ENERGY COMPANY Brine 0 365
2010 MERIDIAN ENERGY COMPANY Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 108 365
2014 BIG SKY ENERGY INC Brine 54 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1032292295 2019-6-12 0:00: PW No Violations
-1618811066 2004-10-29 0:00 PW No Violations
-1866194673 2019-4-17 0:00: PW No Violations
-860410148 2016-12-27 0:00 PW No Violations
0413672175 2011-10-20 Production Wells No Violations no violations .
0468764128 2016-05-03 Production Wells Violations Noted My inspection of the tank battery was equipped with two 100 barrel and one 210 barrel steel tanks and one separator. There was no gas meter at the tank battery location. There was no identification posted at the tank battery area for this well. There was oil saturated soil at the base of one of the 100 barrel tanks on the west and east sides. I took two photos of the oil saturated area on the west side of the tank and one photo of the oil saturated area on east side of the tank. There was a gas leak from a connection on the west side of the separator. The well was equipped with a pumping unit. There was a oil saturated area south from the well piping in an area 8 x 3 on the ground, also the well piping was coated with fresh oil. I took one photo of the oil saturated area and the oil on the well piping. There was gas bubbling through the fluid around the well head. The surface casing head was below the surface. REQUIRED REMEDIAL WORK: Remove all oil saturated areas at the tank battery and well locations. Clean oil from the well piping, repair the gas leaks at the separator and around the well head and post identification at the tank battery area.
0669196233 2016-09-12 Production Wells No Violations My inspection of this well found the oil saturated areas at the tank battery and well locations has not been removed. There was gas still venting from around the well. The gas leak at the separator was not leaking at this time. Identification has not been established at the tank battery location.
0860410148 2016-12-27 Production Wells No Violations My inspection of this well found there has been no remedial work done to resolve the compliance issues with this well. I took three photos of the oil on the ground around the production tanks.
1618811066 2004-10-29 Production Wells No Violations no violations .
413672175 2011-10-20 0:00 PW No Violations
468764128 2016-5-3 0:00:0 PW No Violations
669196233 2016-9-12 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0468764128 US-OH-125082 2016-05-27 Well operation causing pollution and contamination
0468764128 US-OH-125083 2016-05-27 Well insufficiently equipped to prevent escape of oil and gas
0468764128 US-OH-125084 2016-05-27 Failure to legibly identify well

For data sources see[9]

References