34-007-21838

Well Details

Well ID: 34-007-21838
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Williamsfield Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: FLACK
License Status: Producing
License Date: 2006-06-22
Spud Date: 1981-10-10
Spud Drilling Contractor:
Final Drill Date: 1981-10-14
Well Total Depth: 4218.00 ft
Configuration: Vertical
Latitude: 41.570000
Longitude: -80.590000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-09-15 254 EDCO DRILLING & PRODUCING GeoDate 9/15/81
Original Spud 1981-10-10
Completed 1981-10-14
Reached Total Depth 1981-10-14
APP 2005-04-20 Proposed Formations:CLINTON, Issued Date:4/20/2005, Expired Date:4/20/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2005-04-20 Operator changed from 254, EDCO DRILLING & PRODUCING to 1333, BIG SKY ENERGY INC
APP 2006-06-22 Proposed Formations:CLINTON, Issued Date:6/22/2006, Expired Date:6/22/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2007-06-22
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4000 4006 7
2006-09-11 4017 4021 5
4000 4006 7
4000 4006 7

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 316 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 EDCO DRILLING & PRODUCING 3553.00 0.00 365
1988 EDCO DRILLING & PRODUCING 2182.00 95.00 365
1989 EDCO DRILLING & PRODUCING 1890.00 0.00 365
1990 EDCO DRILLING & PRODUCING 1473.00 0.00 365
1991 EDCO DRILLING & PRODUCING 1223.00 40.00 365
1992 EDCO DRILLING & PRODUCING 749.00 0.00 365
1993 EDCO DRILLING & PRODUCING 276.00 0.00 200
1994 MERIDIAN ENERGY COMPANY 763.00 0.00 365
1995 MERIDIAN ENERGY COMPANY 934.00 0.00 365
1996 MERIDIAN ENERGY COMPANY 649.00 0.00 365
1997 MERIDIAN ENERGY COMPANY 403.00 42.00 365
1999 MERIDIAN ENERGY COMPANY 0.00 0.00 0
2000 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2001 BIG SKY ENERGY INC 0.00 0.00 0
2002 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2003 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2004 MERIDIAN ENERGY COMPANY 0.00 0.00 0
2005 MERIDIAN ENERGY COMPANY 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 EDCO DRILLING & PRODUCING Brine 402 365
1988 EDCO DRILLING & PRODUCING Brine 240 365
1989 EDCO DRILLING & PRODUCING Brine 281 365
1990 EDCO DRILLING & PRODUCING Brine 325 365
1991 EDCO DRILLING & PRODUCING Brine 40 365
1992 EDCO DRILLING & PRODUCING Brine 0 365
1993 EDCO DRILLING & PRODUCING Brine 113 200
1994 MERIDIAN ENERGY COMPANY Brine 433 365
1995 MERIDIAN ENERGY COMPANY Brine 0 365
1996 MERIDIAN ENERGY COMPANY Brine 147 365
1997 MERIDIAN ENERGY COMPANY Brine 367 365
1999 MERIDIAN ENERGY COMPANY Brine 0 0
2000 MERIDIAN ENERGY COMPANY Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 0
2002 MERIDIAN ENERGY COMPANY Brine 0 365
2003 MERIDIAN ENERGY COMPANY Brine 0 365
2004 MERIDIAN ENERGY COMPANY Brine 0 0
2005 MERIDIAN ENERGY COMPANY Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1443576515 2017-11-1 0:00: PW No Violations 1.50
-2041553269 2019-12-13 0:00 FR No Violations
001250i173 2002-02-22 Production Wells No Violations NO VIOLATIONS.
1237052015 2018-04-02 Plug / Plug Back No Violations I conducted a compliance notice follow-up inspection for compliance notice 1428333039. At the time of this inspection, the well consisted of the 8 5/8 inch surface casing riser, open at the ground surface. No gas was observed to be present on the open well annulus. The former tank battery location still remains unrestored. There had been no apparent attempt to perform any of the final restoration work as required in the previous inspection reports.
1250i173 2002-2-22 0:00: PW No Violations 0.50
1428333039 2015-03-30 Final Restoration Violations Noted I inspected this well to determine the status of the final restoration. My inspection found a pile of stone in the old tank battery area. There is a two inch steel pipe above ground level located on north side of old tank battery area. I walked to the well location which is located in a crop field. I found the surface casing head above ground level with boards sticking in the well bore. The boards were five foot long. There was a solid structure three feet down the well bore. The well bore was full of fluid. There is small gas bubbles venting through the fluid. This well is not in compliance with 1509 of the Ohio revised code. Remedial work required to get well into compliance: REMOVE STONE FROM TANK BATTERY AREA, REMOVE FLOWLINE OR SUBMIT A LANDOWNER WAIVER FOR THESE ITEMS, DRILL OUT THE WELL BORE AND RE-PLUG WELL.
1436984234 2015-07-15 Plug / Plug Back No Violations I was on site to take photos of the violations [ leaking well, gravel at tank pad, flow line at tank pad ]. I took photos of the pile of gravel at the tank pad area, flow line at the tank pad area and the well head and down the well bore. I spoke to the landowner [Dushan Kalvznik ]. I ask him about waiving the flow line and the pile of gravel at the tank pad area. He told me he will not waive anything relevant to the well.
1443576515 2017-11-01 Production Wells No Violations I inspected this well location as part of on-going enforcement proceedings. As such, the following deficiencies had been noted previously: leakage of gas had been noted from the previously-plugged well, at the surface casing, which had been left open at the ground surface. In addition, final restoration work at the wellhead and former battery location had not been completed. At the time of this inspection, I noted the following: a wellhead consisting of a 8.625-inch surface casing riser, open at the ground surface. Upon inspection, I did not note any gas in the well annulus which was full of water. The former tank battery location remained unrestored. There had been no apparent attempt to perform any of the final restoration work as required.
1474460816 2016-09-20 Plug / Plug Back No Violations My inspection of this well found the tank battery has not been reclaimed. Inspection of the well found there was fluid in the surface casing at ground level. There was gas venting through the fluid at small but steady amount. There has been no attempt from the company to reclaim or re-plug this well.
1618543644 2017-02-17 Plug / Plug Back No Violations Myself, Tom Hill, Rick Anderson, Terry Whitehair and Gene Park with ODNR Division of Oil & Gas met with Bob Barr Sr., Charles Mosio and Gino Pulito with Big Sky Energy on site to discuss the required remedial work needed to comply with the compliance issues with this well.
1751543459 2016-12-16 Plug / Plug Back No Violations My inspection of this well found there has been no attempt from the company to re-plug the leaking plugged well or complete the final restoration.
1936920764 2019-04-08 Production Wells No Violations I conducted a compliance notice follow-up on 04/08/2019. At the time of my inspection the well consisted of the 8 5/8- inch surface casing that was open at ground level. No gas was observed to be present on the open well annulus. No apparent attempt to perform any of the final restoration work as required in the previous inspection reports.
2084350926 2018-05-15 Production Wells No Violations I inspected this well location as part of open compliance violatons. As such, the following deficiencies had been noted previously: leakage of gas had been noted from the previously-plugged well, at the surface casing, which had been left open at the ground surface. In addition, final restoration work at the wellhead and former battery location had not been completed. At the time of this inspection, I noted the following: a wellhead consisting of a 8.625-inch surface casing riser, open at the ground surface. Upon inspection, I did not note any gas in the well annulus which was full of water. There had been no apparent attempt to perform any of the final restoration work as required.
2120217894 2015-07-15 Plug / Plug Back No Violations My inspection of this well found no action has been performed to remediate the compliance issues. I took pictures of the well head and the tank pad areas.
263259952 2020-8-24 0:00: FR No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1428333039 US-OH-112503 2015-04-14 Failure to remove production equip. within 6 mos. REPLACE

For data sources see[9]

References