Well ID: 34-007-21838 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.57,"lon":-80.59,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashtabula | |
Municipality: Williamsfield Township | |
Operator Name: BIG SKY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: FLACK | |
License Status: Producing | |
License Date: 2006-06-22 | |
Spud Date: 1981-10-10 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-10-14 | |
Well Total Depth: 4218.00 ft | |
Configuration: Vertical | |
Latitude: 41.570000 | |
Longitude: -80.590000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1981-09-15 | 254 EDCO DRILLING & PRODUCING GeoDate 9/15/81 |
Original Spud | 1981-10-10 | |
Completed | 1981-10-14 | |
Reached Total Depth | 1981-10-14 | |
APP | 2005-04-20 | Proposed Formations:CLINTON, Issued Date:4/20/2005, Expired Date:4/20/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Change of Owner | 2005-04-20 | Operator changed from 254, EDCO DRILLING & PRODUCING to 1333, BIG SKY ENERGY INC |
APP | 2006-06-22 | Proposed Formations:CLINTON, Issued Date:6/22/2006, Expired Date:6/22/2007 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class: |
Construction Permit Expires | 2007-06-22 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4000 | 4006 | 7 |
2006-09-11 | 4017 | 4021 | 5 |
4000 | 4006 | 7 | |
4000 | 4006 | 7 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 316 Bbl | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1987 | EDCO DRILLING & PRODUCING | 3553.00 | 0.00 | 365 |
1988 | EDCO DRILLING & PRODUCING | 2182.00 | 95.00 | 365 |
1989 | EDCO DRILLING & PRODUCING | 1890.00 | 0.00 | 365 |
1990 | EDCO DRILLING & PRODUCING | 1473.00 | 0.00 | 365 |
1991 | EDCO DRILLING & PRODUCING | 1223.00 | 40.00 | 365 |
1992 | EDCO DRILLING & PRODUCING | 749.00 | 0.00 | 365 |
1993 | EDCO DRILLING & PRODUCING | 276.00 | 0.00 | 200 |
1994 | MERIDIAN ENERGY COMPANY | 763.00 | 0.00 | 365 |
1995 | MERIDIAN ENERGY COMPANY | 934.00 | 0.00 | 365 |
1996 | MERIDIAN ENERGY COMPANY | 649.00 | 0.00 | 365 |
1997 | MERIDIAN ENERGY COMPANY | 403.00 | 42.00 | 365 |
1999 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 0 |
2000 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 365 |
2001 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
2002 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 365 |
2003 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 365 |
2004 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 0 |
2005 | MERIDIAN ENERGY COMPANY | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1987 | EDCO DRILLING & PRODUCING | Brine | 402 | 365 |
1988 | EDCO DRILLING & PRODUCING | Brine | 240 | 365 |
1989 | EDCO DRILLING & PRODUCING | Brine | 281 | 365 |
1990 | EDCO DRILLING & PRODUCING | Brine | 325 | 365 |
1991 | EDCO DRILLING & PRODUCING | Brine | 40 | 365 |
1992 | EDCO DRILLING & PRODUCING | Brine | 0 | 365 |
1993 | EDCO DRILLING & PRODUCING | Brine | 113 | 200 |
1994 | MERIDIAN ENERGY COMPANY | Brine | 433 | 365 |
1995 | MERIDIAN ENERGY COMPANY | Brine | 0 | 365 |
1996 | MERIDIAN ENERGY COMPANY | Brine | 147 | 365 |
1997 | MERIDIAN ENERGY COMPANY | Brine | 367 | 365 |
1999 | MERIDIAN ENERGY COMPANY | Brine | 0 | 0 |
2000 | MERIDIAN ENERGY COMPANY | Brine | 0 | 365 |
2001 | BIG SKY ENERGY INC | Brine | 0 | 0 |
2002 | MERIDIAN ENERGY COMPANY | Brine | 0 | 365 |
2003 | MERIDIAN ENERGY COMPANY | Brine | 0 | 365 |
2004 | MERIDIAN ENERGY COMPANY | Brine | 0 | 0 |
2005 | MERIDIAN ENERGY COMPANY | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1443576515 | 2017-11-1 0:00: | PW | No Violations | 1.50 |
-2041553269 | 2019-12-13 0:00 | FR | No Violations | |
001250i173 | 2002-02-22 | Production Wells | No Violations | NO VIOLATIONS. |
1237052015 | 2018-04-02 | Plug / Plug Back | No Violations | I conducted a compliance notice follow-up inspection for compliance notice 1428333039. At the time of this inspection, the well consisted of the 8 5/8 inch surface casing riser, open at the ground surface. No gas was observed to be present on the open well annulus. The former tank battery location still remains unrestored. There had been no apparent attempt to perform any of the final restoration work as required in the previous inspection reports. |
1250i173 | 2002-2-22 0:00: | PW | No Violations | 0.50 |
1428333039 | 2015-03-30 | Final Restoration | Violations Noted | I inspected this well to determine the status of the final restoration. My inspection found a pile of stone in the old tank battery area. There is a two inch steel pipe above ground level located on north side of old tank battery area. I walked to the well location which is located in a crop field. I found the surface casing head above ground level with boards sticking in the well bore. The boards were five foot long. There was a solid structure three feet down the well bore. The well bore was full of fluid. There is small gas bubbles venting through the fluid. This well is not in compliance with 1509 of the Ohio revised code. Remedial work required to get well into compliance: REMOVE STONE FROM TANK BATTERY AREA, REMOVE FLOWLINE OR SUBMIT A LANDOWNER WAIVER FOR THESE ITEMS, DRILL OUT THE WELL BORE AND RE-PLUG WELL. |
1436984234 | 2015-07-15 | Plug / Plug Back | No Violations | I was on site to take photos of the violations [ leaking well, gravel at tank pad, flow line at tank pad ]. I took photos of the pile of gravel at the tank pad area, flow line at the tank pad area and the well head and down the well bore. I spoke to the landowner [Dushan Kalvznik ]. I ask him about waiving the flow line and the pile of gravel at the tank pad area. He told me he will not waive anything relevant to the well. |
1443576515 | 2017-11-01 | Production Wells | No Violations | I inspected this well location as part of on-going enforcement proceedings. As such, the following deficiencies had been noted previously: leakage of gas had been noted from the previously-plugged well, at the surface casing, which had been left open at the ground surface. In addition, final restoration work at the wellhead and former battery location had not been completed. At the time of this inspection, I noted the following: a wellhead consisting of a 8.625-inch surface casing riser, open at the ground surface. Upon inspection, I did not note any gas in the well annulus which was full of water. The former tank battery location remained unrestored. There had been no apparent attempt to perform any of the final restoration work as required. |
1474460816 | 2016-09-20 | Plug / Plug Back | No Violations | My inspection of this well found the tank battery has not been reclaimed. Inspection of the well found there was fluid in the surface casing at ground level. There was gas venting through the fluid at small but steady amount. There has been no attempt from the company to reclaim or re-plug this well. |
1618543644 | 2017-02-17 | Plug / Plug Back | No Violations | Myself, Tom Hill, Rick Anderson, Terry Whitehair and Gene Park with ODNR Division of Oil & Gas met with Bob Barr Sr., Charles Mosio and Gino Pulito with Big Sky Energy on site to discuss the required remedial work needed to comply with the compliance issues with this well. |
1751543459 | 2016-12-16 | Plug / Plug Back | No Violations | My inspection of this well found there has been no attempt from the company to re-plug the leaking plugged well or complete the final restoration. |
1936920764 | 2019-04-08 | Production Wells | No Violations | I conducted a compliance notice follow-up on 04/08/2019. At the time of my inspection the well consisted of the 8 5/8- inch surface casing that was open at ground level. No gas was observed to be present on the open well annulus. No apparent attempt to perform any of the final restoration work as required in the previous inspection reports. |
2084350926 | 2018-05-15 | Production Wells | No Violations | I inspected this well location as part of open compliance violatons. As such, the following deficiencies had been noted previously: leakage of gas had been noted from the previously-plugged well, at the surface casing, which had been left open at the ground surface. In addition, final restoration work at the wellhead and former battery location had not been completed. At the time of this inspection, I noted the following: a wellhead consisting of a 8.625-inch surface casing riser, open at the ground surface. Upon inspection, I did not note any gas in the well annulus which was full of water. There had been no apparent attempt to perform any of the final restoration work as required. |
2120217894 | 2015-07-15 | Plug / Plug Back | No Violations | My inspection of this well found no action has been performed to remediate the compliance issues. I took pictures of the well head and the tank pad areas. |
263259952 | 2020-8-24 0:00: | FR | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1428333039 | US-OH-112503 | 2015-04-14 | Failure to remove production equip. within 6 mos. REPLACE |
For data sources see[9]