X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-21673

Well Details

Well ID: 34-007-21673
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Colebrook Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: PERRY H
License Status: Active Injection
License Date: 1981-08-19
Spud Date: 1981-03-06
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 1981-03-11
Well Total Depth: 3860.00 ft
Configuration: Vertical
Latitude: 41.570000
Longitude: -80.770000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1981-03-06 CONVERT TO SWDW
Completed 1981-03-11 CONVERT TO SWDW
Reached Total Depth 1981-03-11 CONVERT TO SWDW
Completion Report Received 1981-06-22 CONVERT TO SWDW
CO 1981-08-13 277 ATWOOD ENERGY INC GeoDate 8/13/81
Unknown 1981-08-13 Issued Date 8/13/81 Expired Date 8/13/82 Acres 0000000 Tool Type Proposed Formation Proposed Depth 00000 Proposed Drill Depth 00000
Conversion to Injector 1981-08-19
Plugged Back 1981-08-19 CONVERT TO SWDW
First Injection 1981-10-01 CONVERT TO SWDW
Construction Permit Expires 1982-08-13 CONVERT TO SWDW
Annulus Pressure Monitoring Approved 1991-05-02 CONVERT TO SWDW
CO 1995-08-07 4205 TRANSFUEL RESOURCES CO GeoDate 8/13/81
CO 1995-10-27 213 LOMAK OPERATING CO GeoDate 8/13/81
CO 1996-09-13 4930 CANTON OIL & GAS COMPANY GeoDate 8/13/81
Change of Owner 2004-07-14 Operator changed from 4930, CANTON OIL & GAS COMPANY to 7666, ARVILLA OILFIELD SERVICES LLC
Change of Owner 2005-07-27 Operator changed from 7666, ARVILLA OILFIELD SERVICES LLC to 1333, BIG SKY ENERGY INC
Last Compliance Report 2014-07-31 CONVERT TO SWDW
Record Last Modified 2017-02-15 CONVERT TO SWDW

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-04-27 3390 3418 2
2000-04-27 3658 3730 1
3390 3418 2
3658 3730 1
3390 3418 2

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1000 Gal 0
H2O 0 82068 Gal 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 ATWOOD ENERGY INC 0.00 0.00 365
1988 ATWOOD ENERGY INC 0.00 0.00 365
1989 ATWOOD ENERGY INC 0.00 0.00 365
1990 ATWOOD ENERGY INC 0.00 0.00 365
1991 ATWOOD ENERGY INC 0.00 0.00 365
1992 ATWOOD RESOURCES INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 ATWOOD ENERGY INC Brine 1870 365
1988 ATWOOD ENERGY INC Brine 1015 365
1989 ATWOOD ENERGY INC Brine 620 365
1990 ATWOOD ENERGY INC Brine 910 365
1991 ATWOOD ENERGY INC Brine 415 365
1992 ATWOOD RESOURCES INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1044448876 2013-9-24 0:00: SW No Violations
-1082495966 2011-6-7 0:00:0 SW No Violations
-1090288849 2020-1-15 0:00: SW No Violations 1.00
-1138986535 2020-3-3 0:00:0 SW No Violations 1.20
-1147166741 2006-7-13 0:00: SW No Violations
-1175463793 2018-2-16 0:00: SW No Violations
-1177949407 2019-2-11 0:00: SW No Violations
-1226043144 2006-3-9 0:00:0 SW No Violations
-1305466377 2006-12-6 0:00: SW No Violations
-1306139932 2010-8-16 0:00: SW No Violations
-1346306909 2012-2-24 0:00: SW No Violations
-1371970122 2017-9-12 0:00: SW No Violations
-1497882048 2019-4-29 0:00: SW No Violations
-1523628507 2010-8-5 0:00:0 SW No Violations
-1530752211 2013-8-7 0:00:0 SW No Violations
-1544311648 2003-3-28 0:00: SW No Violations
-1568124325 2011-9-22 0:00: SW No Violations
-1581033009 2018-11-19 0:00 SW No Violations 1.00
-1621831252 2015-10-7 0:00: SW No Violations
-1662707990 2004-8-27 0:00: SW No Violations
-1688828412 2006-7-7 0:00:0 SW No Violations
-1776093633 2003-8-26 0:00: SW No Violations
-179221887 2010-8-9 0:00:0 SW No Violations
-1815117813 2019-8-8 0:00:0 SW No Violations 1.00
-1816264697 2005-8-10 0:00: SW No Violations
-1879316166 2005-1-28 0:00: SW No Violations
-1884515009 2007-6-19 0:00: SW No Violations
-1904920627 2009-10-15 0:00 SW No Violations
-1908657593 2018-2-27 0:00: SW No Violations 0.70
-1920551655 2008-12-9 0:00: SW No Violations
-1949412315 2010-1-26 0:00: SW No Violations
-1971409939 2014-2-25 0:00: SW No Violations
-236818114 2006-5-18 0:00: SW No Violations
-248533971 2009-3-25 0:00: SW No Violations
-283978563 2005-5-9 0:00:0 SW No Violations
-306145749 2013-10-18 0:00 SW No Violations
-320925670 2016-3-18 0:00: SW No Violations
-396217935 2020-4-23 0:00: SW No Violations
-449026714 2018-10-26 0:00 SW No Violations 0.50
-451816085 2019-9-11 0:00: SW No Violations
-453931456 2007-9-4 0:00:0 SW No Violations
-597653662 2006-9-22 0:00: SW No Violations
-628340354 2019-1-2 0:00:0 SW No Violations 1.00
-664642191 2010-9-14 0:00: SW No Violations
-736505289 2018-5-3 0:00:0 SW No Violations
-872939254 2012-12-7 0:00: SW No Violations
-910138782 2007-3-8 0:00:0 SW No Violations
-923296357 2008-3-18 0:00: SW No Violations
-941938367 2014-5-9 0:00:0 SW No Violations
-964344009 2018-5-15 0:00: SW No Violations 1.00
-997564728 2003-7-11 0:00: SW No Violations
0000UIC875 1990-04-12 Salt Water Injection Well No Violations 1501:9-3-05 (6) CONSTRUCTION & CONVE
000UIC1007 1990-11-28 Salt Water Injection Well No Violations 1509.22 A 1.2 C-STORAGE & DISPOSAL
000UIC1008 1990-11-28 Salt Water Injection Well No Violations 1501.9-3-04
000UIC1163 1991-09-18 Salt Water Injection Well No Violations 1501: 9-3-07 (E)&(F) QUARTERLY REPORTS
000UIC1310 1992-10-01 Salt Water Injection Well No Violations 1509.03 RULES & REGULATIONS
000UIC1311 1992-10-01 Salt Water Injection Well No Violations 1501: 9-3-04 PREVENT CONTAMINAT.
000UIC1312 1992-10-01 Salt Water Injection Well No Violations 1501: 9-3-05 (B) (7) STORAGE FACILITIES
001250i215 2002-04-23 Salt Water Injection Well No Violations Check U.I.C. facility.
001250i277 2002-09-25 Salt Water Injection Well No Violations Inspection per request by Curtis Hill [ local resident ] . Inspection showed well pressures are within allowable limits. Conversation with Don Gooseman[field supervisor] by telephone he advised me they had recently replaced the injection line from pump house to wellhead. I then advised him a pressure test is required of new injection line. He scheduled a test for Friday [9-27-02].
001250i283 2002-09-27 Salt Water Injection Well No Violations On site to pressure test injection line. Pressure injection line to 1100 P.S.I. And shut-in for 15 minutes with 0 P.S.I. Loss. Pressure test passed.
0033033749 2015-03-05 Salt Water Injection Well No Violations My inspection of the storage facility and the well pressures found no compliance issues. I was unable to get a pressure reading of the tubing annulus due to a frozen valve.
0036016920 2013-04-26 Salt Water Injection Well No Violations Inspection of injection well pressures and storage facility found no violations ,
0058326702 2010-08-10 Salt Water Injection Well No Violations Company pumping fluid through tubing and circulating to surface with Duplex mud pump in a attempt release packer with no success .
0124322948 2011-02-23 Salt Water Injection Well No Violations check uic facility.
0125260645 2018-06-11 Salt Water Injection Well No Violations I found no evidence of recent activity. There are several inches of standing water inside the diked tank battery. The equipment in the green shed has a corroded appearance. I was unable to gauge the annulus due to fittings need replaced. Overgrown vegetation surrounds the entire facility. An identification sign is posted.
0179221887 2010-08-09 Salt Water Injection Well No Violations Company still trying to release packer with no success .
0236818114 2006-05-18 Salt Water Injection Well No Violations check uic facility .
0248533971 2009-03-25 Salt Water Injection Well No Violations check uic facility .
0249319227 2016-11-07 Salt Water Injection Well No Violations Inspection of this well found there has been no action to remediate the contamination issues at and around the storage facility. There was one foot of fluid inside the storage impoundment area. The buried sump tanks for the unloading pad and the pump house were full to point of overflowing. This well was not in operation at the time of my inspection.
0283978563 2005-05-09 Salt Water Injection Well No Violations no violations .
0306145749 2013-10-18 Salt Water Injection Well No Violations Inspection found the underground tanks for the pump house and the unloading pad have been emptied . There is about 8 of fluid inside the impoundment walls around the storage tanks . There has been no action to clean-up oil stained gravel and soil or to clean the fresh oil from pump house floor . I spoke with Bob Barr Jr. and he told me they are repairing their high pressure steam cleaner to complete the remedial work . He gave me no certain time frame for completion of the remedial work .
0320925670 2016-03-18 Salt Water Injection Well No Violations I was accompanied by Jen Barret, Dan Martin, Mike Williams [ Attorney Generals Office ], Rick Anderson and Tom Hill [ ODNR Division of Oil & Gas ]. I took photos of the areas inside the impoundments for the storage tanks and the sump pump on the north side of the pump house.
0338937131 2016-12-08 Salt Water Injection Well No Violations Myself and Tom Hill inspected the storage facility to find the company has not performed any remediation to resolve the compliance issues with this well. Tom took photos of the storage facility and the buried collection tanks for the unloading pad and the pump house.
0376250163 2014-11-26 Salt Water Injection Well No Violations My inspection of the well pressures and the storage facility found no compliance issues.
0449026714 2018-10-26 Salt Water Injection Well No Violations I found no evidence of recent activity. There has been no remediation started. There are several inches of water in the diked tank battery. The side of the dike is oil stained. The pump house garage door is open and the equipment inside has a corroded appearance. There injection well has a rusty appearance. There is overgrown vegetation around the facility and well. A slightly faded identification sign is posted. Photos were taken and are available upon request.
0453931456 2007-09-04 Salt Water Injection Well No Violations check uic facility .
0464796672 2011-11-16 Salt Water Injection Well No Violations Status check of underground injection facility.
0477451005 2015-05-28 Salt Water Injection Well No Violations Myself, Tom Hill and Rick Anderson inspected the site. There has been no remedial work performed.
0519389591 2003-11-07 Preliminary Restoration No Violations Check U.I.C. facility .
0547927144 2012-09-20 Salt Water Injection Well No Violations My inspection of injection well pressures and the storage facility found no violations .
0567464977 2006-07-18 Salt Water Injection Well No Violations Company building dike around pumphouse .
0597653662 2006-09-22 Salt Water Injection Well No Violations check uic facility .
0628340354 2019-01-02 Salt Water Injection Well No Violations
0664642191 2010-09-14 Salt Water Injection Well No Violations Company attempting to fish seperated tubing from well with no success .
0684767765 2004-10-28 Salt Water Injection Well No Violations Check U.I.C. facility .
0704045293 2017-02-17 Salt Water Injection Well No Violations Myself, Tom Hill, Rick Anderson, Terry Whitehair and Gene Park with ODNR Division of Oil & Gas met with Bob Barr Sr., Charles Mosio and Gino Pulito with Big Sky Energy on site to discuss the required remedial work needed to comply with the compliance issues with this well.
0736505289 2018-05-03 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the 2017 Salt Water Injection Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. Report received, 5/12/2018
0872939254 2012-12-07 Salt Water Injection Well No Violations My inspection of injection well pressures and storage facility found no violations .
0910138782 2007-03-08 Salt Water Injection Well No Violations CHECK UIC FACILITY
0912417490 2017-02-28 Salt Water Injection Well No Violations Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017Reports received 3/15/2017
0923296357 2008-03-18 Salt Water Injection Well No Violations no violations .
0941938367 2014-05-09 Salt Water Injection Well No Violations My inspection found there has been no further action to comply with the compliance notice issued on 8-7-2013 . The deadline was on 9-27-2013 . The well was not in operation at this time .
0948207629 2008-06-13 Salt Water Injection Well No Violations check uic facility .
0964109548 2010-04-21 Salt Water Injection Well No Violations CHECK UIC FACILITY
0964344009 2018-05-15 Salt Water Injection Well No Violations I inspected this well location as part of an evaluation of open compliance violations. As such, the following deficiencies had previously been noted: release of oilfield fluids (oil and brine) from the storage tanks, into the impoundment, and the fluid unloading areas requiring remediation. At the time of this inspection, I noted the following: the facility was inactive and in a state of disrepair, with a small pump house structure, a multi-tank battery with a receiving dock station, and a single well that had been utilized as a brine disposal injection location. The tank battery system was comprised of four 210-barrel steel tanks and one 100-barrel steel tank within a common, earthen, plastic-lined impoundment structure that formed a secondary containment system. The secondary containment was filled with several inches of rusty water and oily sludge, with oily staining on the sidewalls. The piping system and tanks were extensively corroded with numerous perforations. The tanks were full to within 2 feet of the top, with fluid. The unloading dock and associated collection sump was full of oily sludge. The pump house shed contained a sump collection system and associated pumping apparatus. The sump was full to grade with oily water, and the interior of the shed was coated with oily staining. Adjacent to the shed was an approximate ten thousand gallon portable steel storage tank, the contents of which were not ascertainable. 150 feet east of the impoundment and shed was the wellhead, in an open field. The wellhead was comprised of a 4.5-inch casing with 1-inch flexible flow-line fittings and connections. There was an approximate 15 by 15 earthen pad with shallow berm surrounding the well. There was no visible active leaking fluids or gas from any portions of the system. There was no evidence that any actions had been taken to remedy or mitigate the impacted areas.
0997564728 2003-07-11 Salt Water Injection Well No Violations Check U.I.C. facility .
1044448876 2013-09-24 Salt Water Injection Well No Violations The statis of any remedial work to comply with the compliance notice has not changed since my inspection on 9-11-2013 . No remedial action at all .
1081633549 2004-04-06 Salt Water Injection Well No Violations Check UIC facility .
1082495966 2011-06-07 Salt Water Injection Well No Violations no violations .
1085297020 2013-07-15 Salt Water Injection Well No Violations Inspection of injection well pressures and storage facility found no violations .
1088338902 2015-12-02 Production Wells No Violations I conducted an inspection of this well and found that the emptied 300 BBL frac tank was still on site and had not been removed. There was excessive fluid in the sump tanks and in the storage facility area. Stained soil around the sump tanks was also observed at the time of this inspection.
1117584484 2005-04-05 Salt Water Injection Well No Violations Complaintant ; Curtis Hill . Inspection of injection well showed no violations . Myself and suprv. Cheslock talked with Mr. Hill per complaint [ contaminated water well ] , we asked him to acquire water samples from his water well to dertermine if contamination was related to oil & gas well . He advised us he did not want us to collect any samples from his well . Mr. Hill told us even if we took a sample and it tested no contamination he still would not drink the water because he had it tested in 1985 and at that time the person testing the well told him the water could be safe to drink one day but the contaminate could reapear days later , not making it safe to drink . Myself and suprv. Cheslock left site without collecting a water sample .
1147166741 2006-07-13 Salt Water Injection Well No Violations Check oil spill clean-up progress . Some clean-up still needed .
1152287950 2006-07-05 Salt Water Injection Well Violations Noted Arrived on site to find a oil spill from pump house flowing west 100 to road culvert at route 46 , through culvert to west side of road into storm ditch . Oil then flowed approximately 350 into low area , then spread out approximately 50 to 75 wide in very thick grass . After oil spread out it traveled approximately 100 then stopped . Bob Barr with Big Sky Energy advised me they lost approximately 10-20 barrel of oil and 60 barrel of brine from facility . I contacted EPA and advised them of spill . Jim Urwin with EPA arrived on site and inspected spill . NOTE: Company was already cleaning oil spill up .I collected water sample from three homes north and south of spill . House numbers 6419,6375 and 6353 . Samples were taken to lab for analysis .
1153668682 2006-07-21 Salt Water Injection Well No Violations Remedial work has been completed . No violations . RESOLVED .
1162055440 2008-09-24 Salt Water Injection Well No Violations check uic facility .
1175463793 2018-02-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. REPORTS RECEIVED BY THE DIVISION FEBRUARY 26, 2018
1177949407 2019-02-11 Salt Water Injection Well Violations Noted The Division has not received the 1st, 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019.
1185403714 2006-08-09 Salt Water Injection Well No Violations On site to collect soil samples in oil spill area . After collection of soil samples , a field test of dilluted samples with 1176 quantab showed 0 chlorides . A lab test is not required at this time .
1189255003 2014-08-29 Salt Water Injection Well No Violations Inspection of the well pressures and the storage facility found no violations.
1226043144 2006-03-09 Salt Water Injection Well No Violations Case# 06-005 , Curtis Hill . Inspection showed no visible violations . While on site a brine truck from Petrowater unloaded brine causing a loud screeching noise . Conf. With brine hauler revealed the unloading valve was insufficient causing him to by-pa
124322948 2011-2-23 0:00: SW No Violations
1250i215 2002-4-23 0:00: SW No Violations 0.50
1250i277 2002-9-25 0:00: SW No Violations 0.70
1250i283 2002-9-27 0:00: SW No Violations 3.50
125260645 2018-6-11 0:00: SW No Violations 0.50
1282532533 2015-12-31 Salt Water Injection Well No Violations My inspection of this well found the well was not in operation, the excessive fluid in the sump tanks and the fluid in the containment area for the storage tanks has not been removed.
1285863038 2010-08-02 Salt Water Injection Well No Violations Company is blowing down well to pull tubing and packer .
1288519977 2009-06-26 Salt Water Injection Well No Violations check uic facility .
1305466377 2006-12-06 Salt Water Injection Well No Violations Check UIC facility .
1306139932 2010-08-16 Salt Water Injection Well No Violations Company still attempting to release packer . Rig pulled 93 thousand lbs on tubing when it seperated approx. 300 down hole .
1333885140 2015-05-06 Salt Water Injection Well No Violations My inspection of the well pressures no compliance issues. I found there was fluid inside the impoundment one and a half feet deep. The underground tanks for the unloading pad and the pump house were full of fluid to the point of running over. I contacted Don Goosman and told him of the excessive fluid in the impoundment and the underground tanks. He told me he would have them emptied within a few days.
1339685128 2012-06-14 Salt Water Injection Well No Violations My inspection of injection well pressures and the storage facility found no violations.
1346306909 2012-02-24 Salt Water Injection Well No Violations check uic facility .
1350431454 2010-09-15 Salt Water Injection Well No Violations Company run impression tool to determine statis of seperated tubing .
1371970122 2017-09-12 Salt Water Injection Well No Violations At the time of my inspection the operator had isolated the storage tanks by closing the valves at the bottom of the tanks. No action has been taken to remove free brine and oil from the containment. Scalding along the north side of the tank battery was evident (barren areas in the agricultural field and dead vegetation.) Sump behind the pump house was still full of fluid. The pump motor remained in disrepair. The sumps at the west end of the unloading pad remained full.
1393430856 2014-02-25 Salt Water Injection Well No Violations
1413226684 2014-07-31 Salt Water Injection Well No Violations Myself and supervisor Hill were on site to witness mechanical integrity test on annulus of production casing. Company pressured the annulus of the production casing to 1100 psi and then shut-in the annulus and held the pressure for 15 minutes with no drop in the pressure. The test passed. After further inspection of the remedial work required by the compliance notice issued on 8-7-2014. The remedial wok has been completed. The compliance notice has been resolved.
1414422365 2004-05-07 Salt Water Injection Well No Violations Check U.I.C. facility .
1434458220 2015-05-27 Salt Water Injection Well No Violations My inspection found the excessive fluid in the buried tanks and the facility has not been removed.
1446939867 2010-08-06 Salt Water Injection Well No Violations Company still unable to release packer.
1451370259 2019-6-13 0:00: SW No Violations 1.00
1497882048 2019-04-29 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019.
1506520065 2017-09-27 Salt Water Injection Well No Violations
1509564265 2017-11-01 Salt Water Injection Well No Violations I inspected this well location as part of on-going enforcement proceedings. As such, the following deficiencies had been noted: release of oilfield fluids (oil and brine) from the storage tanks, into the impoundment, and the fluid unloading areas requiring remediation. At the time of this inspection, I noted the following: the facility appeared to have been inactive for an extended amount of time. The There was a tank battery system comprised of four 210-barrel steel tanks and one 100-barrel steel tank within a common, earthen, plastic-lined impoundment structure that formed a secondary containment system. The tanks were full to within 2 feet of the top, with fluid. The secondary containment was partially filled with water and substantial oily sheen and rust, and extensive oily staining along the sidewalls. There was an unloading dock with subsurface tanks for fluid collection which were full to ground surface with oily water. Adjacent to the tank impoundment was a small pump house shed with sump collection system and associated pumping apparatus. The sump was full to grade with oily water, and the interior of the shed was coated with oily staining. I tested the ponded water within the impoundment and found the pH to be 6-7, and the chloride level to be less than 400 ppm. Adjacent to the shed was an approximate ten thousand gallon portable steel storage tank, the contents of which were not ascertainable. 150 feet east of the impoundment and shed was the wellhead, in an open field. The wellhead was comprised of a 4.5-inch casing with 1-inch flexible flow-line fittings and connections. The flow-line valves were open. There was an approximate 15 by 15 earthen pad with shallow berm surrounding the well. The bermed area was full of water which I tested and found to be pH 6-7, and less than 400 ppm chlorides. There was no visible active leaking fluids or gas from any portions of the system. There was no evidence that any actions had been taken to remedy or mitigate the
1509718505 2017-11-03 Salt Water Injection Well No Violations

-up line connecting the storage tanks is under water and has a rusty/corroded appearance. The unloading pad is surrounded by overgrown vegetation and has standing water. An identification sign is posted on the walkway along the storage tanks. Photos have been taken and are available upon request.

1521818587 2018-03-23 Salt Water Injection Well No Violations I found no change from the previous inspection. Big Sky Energy has not begun any remediation. There is no evidence of recent activity. The injection well is not in operation. I was unable to gauge the annulus due to corroded fitting. The storage tanks are still surrounded by several inches of standing water with old oil residue. Photos were taken and available upon request.
1523628507 2010-08-05 Salt Water Injection Well No Violations Company pumping fresh water through tubing and circulating to surface in a attempt to release packer . They were still unable to release packer .
1530752211 2013-08-07 Salt Water Injection Well Violations Noted Inspection of the storage facility I found a fresh oil stained area 10 X 3 located between the pump house and the impoundment area . Further inspection I found the fluid level inside the dike walls was 2 deep , also the underground sump tank for the unloading pad was full of fluid to the point of overflowing . The underground sump tank for the pump house located on the north side of the pump house was full of fluid to the point of overflowing . Inspection of the interior of the pump house I found fresh oil lying over the entire area of the pump house floor . There was a new electric motor installed to run the injection pump but it had no belts installed to operate the injection pump . The well was not in operation at the time of my inspection . REMEDIAL WORK REQUIRED TO RESOLVE THE COMPLIANCE NOTICE : REMOVE ALL THE OIL STAINED MATERIAL AND DISPOSE OF IN AN APPROVED MANNER , REMOVE ALL THE EXCESSIVE FLUIDS FROM THE IMPOUNDMENT AREA AND THE UNDERGROUND TANKS FOR THE UNLOADING PAD AND THE PUMP HOUSE , CLEAN ALL THE FREE OIL FROM THE PUMP HOUSE FLOOR . NOTE: I contacted Bob Barr Jr. and told him of the compliance notice and the remedial action needed to resolve the compliance notice .
1544311648 2003-03-28 Salt Water Injection Well No Violations Check U.I.C. facility.
1555681811 2019-04-19 Salt Water Injection Well No Violations
1568124325 2011-09-22 Salt Water Injection Well No Violations Status check of underground injection facility.
1572437128 2007-12-27 Salt Water Injection Well No Violations check uic facility .
1576157943 2019-12-11 0:00 SW No Violations 4.00
1577191662 2019-12-23 0:00 SW No Violations 8.00
1581033009 2018-11-19 Salt Water Injection Well No Violations I found no evidence of recent activity. The facility equipment and injection well are highly corroded and rusty in appearance. The garage door on the pump house is open. There are several inches of water in the diked tank battery and around the injection well. A partially faded identification sign is posted.
1588783729 2020-5-6 0:00:0 SW No Violations
1596639800 2020-8-5 0:00:0 SW No Violations 1.10
1597928583 2020-8-20 0:00: SW No Violations
1601021558 2003-05-30 Salt Water Injection Well No Violations Check U.I.C. facility .
1621831252 2015-10-07 Salt Water Injection Well No Violations Inspection of this well found the well is not in operation at this time. The sump tanks for the pump house and the unloading pad are full of fluid to the point of overflowing. There was 1.5 feet of fluid inside the storage facility impoundment for the storage tanks.
1662707990 2004-08-27 Salt Water Injection Well No Violations Check UIC facility .
1674930927 2006-07-06 Salt Water Injection Well No Violations On site for oil spill clean-up .
1679810575 2005-11-18 Salt Water Injection Well No Violations Check U.I.C. facility .
1688828412 2006-07-07 Salt Water Injection Well No Violations On site for oil spill clean-up .
1714747071 2013-09-11 Salt Water Injection Well No Violations Inspection found there is over a foot of water inside the impoundment around the storage tanks and the underground tanks for the pump house and the unloading pad are still full of fluid to the point of overflowing . There has been no action from the company to clean-up the fresh oil lying over the pump house floor or to remove oil saturated gravel and soil on west side of pump house .
1738689943 2016-06-22 Salt Water Injection Well No Violations My inspection found the sump tanks for the pump house and the unloading pad were full of fluid to point of overflowing. There was 4-6 inches of fluid inside the storage impoundment for the brine storage tanks. This well was not in operation at the time of my inspection.
1753780672 2003-09-17 Salt Water Injection Well No Violations Check U.I.C. facility per request from Curtis Hill .
1753925101 2015-07-21 Salt Water Injection Well No Violations My inspection found the leaking 300 bbl frac tank has been emptied. There is still excessive fluid in the sump tanks and in the storage facility.
1765786079 2018-07-18 Salt Water Injection Well No Violations I found no evidence that Big Sky Energy has performed any remediation or clean-up operations. The ball valve on the tubing at the injection well is in the open position. The fittings on the annulus are corroded. There is crystalized salt on the wellhead. Overgrown vegetation surrounds the facility. There are several inches of water in the diked tank battery with oil residue. A faded identification sign is posted. The equipment inside of the pump house has a corroded appearance. Photos were taken and are available upon request.
1776093633 2003-08-26 Salt Water Injection Well No Violations Check U.I.C. facility .
178325877 2020-1-3 0:00:0 SW No Violations
1816264697 2005-08-10 Salt Water Injection Well No Violations Check uic facility .
1879316166 2005-01-28 Salt Water Injection Well No Violations check uic facility .
1884515009 2007-06-19 Salt Water Injection Well No Violations CHECK UIC FACILITY .
1904920627 2009-10-15 Salt Water Injection Well No Violations check uic facility .
1908657593 2018-02-27 Salt Water Injection Well No Violations
1920551655 2008-12-09 Salt Water Injection Well No Violations check uic facility .
1949412315 2010-01-26 Salt Water Injection Well No Violations no violations .
1961004348 2013-08-28 Salt Water Injection Well No Violations Inspection found there has been no remedial work done to comply with the compliance notice issued on 8-07-2013 . NOTE: There is one foot of fluid inside dike walls , also the underground sump tanks for the pump house and the unloading pad are full of fluid to point of overflowing .
1971409939 2014-02-25 Salt Water Injection Well No Violations I checked this well for remedial work in accordance with the compliance notice issued on 8-7-2013 and to determine if the company is in compliance with the chiefs order #2014-43 . Upon my inspection I found there is still oil saturated soil and gravel on the west side of the pump house and the pump house floor is still covered with wet oil . The injection pump motor has been installed and the injection line is hooked-up to the injection pump . There was not a pressure release switch installed on the pressure side of the injection pump . The injection pump was not operating at the time of my inspection . Upon further inspection of the well pressures I found the tubing had 400 psi and the annulus had 490 psi . There has been 0 psi on the tubing and the annulus for the last 3 inspections dating back to 7-15-2013 . There is a indication that a mechanical integrity test should be performed before any further injection of fluid is done . I will address the integrity test and the pressure release switch when the chiefs order # 2014-43 is resolved .
2006787765 2006-07-11 Salt Water Injection Well No Violations On site for oil spill clean-up .
2086502563 2010-08-04 Salt Water Injection Well No Violations Company attemting to release packer with no success .
2116064473 2015-06-02 Salt Water Injection Well No Violations I was on site to assist Kyle Tharp in collecting water samples. The company has not removed the excessive fluid from the storage facility.
249319227 2016-11-7 0:00: SW No Violations
33033749 2015-3-5 0:00:0 SW No Violations
338937131 2016-12-8 0:00: SW No Violations
36016920 2013-4-26 0:00: SW No Violations
376250163 2014-11-26 0:00 SW No Violations
464796672 2011-11-16 0:00 SW No Violations
477451005 2015-5-28 0:00: SW No Violations
519389591 2003-11-7 0:00: PL No Violations
547927144 2012-9-20 0:00: SW No Violations
567464977 2006-7-18 0:00: SW No Violations
58326702 2010-8-10 0:00: SW No Violations
627558330 2020-3-5 0:00:0 SW No Violations
684767765 2004-10-28 0:00 SW No Violations
704045293 2017-2-17 0:00: SW No Violations
912417490 2017-2-28 0:00: SW No Violations
948207629 2008-6-13 0:00: SW No Violations
964109548 2010-4-21 0:00: SW No Violations
UIC1007 1990-11-28 0:00 SW No Violations
UIC1008 1990-11-28 0:00 SW No Violations
UIC1163 1991-9-18 0:00: SW No Violations
UIC1310 1992-10-1 0:00: SW No Violations
UIC1311 1992-10-1 0:00: SW No Violations
UIC1312 1992-10-1 0:00: SW No Violations
UIC875 1990-4-12 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0736505289 US-OH-128370 2018-07-17 9-3-04B Failure to file salt water injection annual report
1152287950 US-OH-103961 2006-07-07 Pollution/Contamination
1175463793 US-OH-104651 2018-03-21 NONE Failure to report disposal fees
1177949407 US-OH-104729 2019-04-08 NONE Failure to report disposal fees
1497882048 US-OH-114043 2019-06-06 9-3-04B Failure to file salt water injection annual report
1530752211 US-OH-114688 2013-09-19 Pollution/Contamination

For data sources see[9]

References