X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-21422

Well Details

Well ID: 34-007-21422
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Sheffield Township
Operator Name: WUENSCHEL JEFF
Well Pad ID:
Farm/Lease Name: CUSANO JAMES
License Status: Domestic Well
License Date: 1981-03-13
Spud Date: 1981-07-14
Spud Drilling Contractor:
Final Drill Date: 1981-07-19
Well Total Depth: 3250.00 ft
Configuration: Vertical
Latitude: 41.850000
Longitude: -80.660000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-03-13 1634 NORTHWOOD ENERGY CORP GeoDate 3/13/81
Original Spud 1981-07-14 R.I. 3-19-81. CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM BIG SKY ENERGY #1333 TO OWNER ON 12/15/2017 CM.
Completed 1981-07-19 R.I. 3-19-81. CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM BIG SKY ENERGY #1333 TO OWNER ON 12/15/2017 CM.
Reached Total Depth 1981-07-19 R.I. 3-19-81. CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM BIG SKY ENERGY #1333 TO OWNER ON 12/15/2017 CM.
Change of Owner 2001-05-29 Operator changed from 1634, NORTHWOOD ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Last Compliance Report 2017-08-17 R.I. 3-19-81. CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM BIG SKY ENERGY #1333 TO OWNER ON 12/15/2017 CM.
Change of Owner 2017-12-15 Operator changed from 1333, BIG SKY ENERGY INC to 10026, WUENSCHEL JEFF
Record Last Modified 2017-12-15 R.I. 3-19-81. CHANGED STATUS OF WELL FROM PR TO DM PER TRANSFER FROM BIG SKY ENERGY #1333 TO OWNER ON 12/15/2017 CM.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3110 3130 16
2006-09-11 3162 3170 4
3110 3130 16
3110 3130 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 900 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 BRALKO ENERGY INC 7052.00 39.00 0
1986 BRALKO ENERGY INC 4182.00 0.00 365
1987 BRALKO ENERGY INC 6879.00 56.00 365
1988 WHITE J P 7667.00 65.00 365
1989 WHITE J P 3201.00 0.00 365
1990 NORTHWOOD ENERGY CORP 2390.00 37.00 245
1991 NORTHWOOD ENERGY CORP 14.00 0.00 365
1992 NORTHWOOD ENERGY CORP 1144.00 0.00 365
1994 NORTHWOOD ENERGY CORP 937.00 0.00 365
1995 NORTHWOOD ENERGY CORP 232.00 0.00 365
1996 NORTHWOOD ENERGY CORP 445.00 0.00 365
1997 NORTHWOOD ENERGY CORP 339.00 0.00 365
1998 NORTHWOOD ENERGY CORP 341.00 0.00 365
1999 NORTHWOOD ENERGY CORP 310.00 0.00 365
2000 NORTHWOOD ENERGY CORP 0.00 61.00 365
2001 BIG SKY ENERGY INC 313.00 0.00 180
2003 BIG SKY ENERGY INC 1238.00 0.00 365
2004 BIG SKY ENERGY INC 441.00 0.00 365
2006 BIG SKY ENERGY INC 1146.00 0.00 365
2007 BIG SKY ENERGY INC 1636.00 0.00 365
2008 BIG SKY ENERGY INC 1804.00 0.00 365
2009 BIG SKY ENERGY INC 2172.00 0.00 365
2011 BIG SKY ENERGY INC 1003.00 0.00 365
2012 BIG SKY ENERGY INC 673.00 0.00 366
2013 BIG SKY ENERGY INC 241.00 0.00 280
2014 BIG SKY ENERGY INC 89.00 0.00 280
2015 TUSSEL CLARENCE JR 0.00 0.00 0
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 BRALKO ENERGY INC Brine 363 0
1986 BRALKO ENERGY INC Brine 220 365
1987 BRALKO ENERGY INC Brine 581 365
1988 WHITE J P Brine 697 365
1989 WHITE J P Brine 232 365
1990 NORTHWOOD ENERGY CORP Brine 121 245
1991 NORTHWOOD ENERGY CORP Brine 77 365
1992 NORTHWOOD ENERGY CORP Brine 55 365
1994 NORTHWOOD ENERGY CORP Brine 115 365
1995 NORTHWOOD ENERGY CORP Brine 50 365
1996 NORTHWOOD ENERGY CORP Brine 40 365
1997 NORTHWOOD ENERGY CORP Brine 110 365
1998 NORTHWOOD ENERGY CORP Brine 410 365
1999 NORTHWOOD ENERGY CORP Brine 158 365
2000 NORTHWOOD ENERGY CORP Brine 365
2001 BIG SKY ENERGY INC Brine 0 180
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 280
2014 BIG SKY ENERGY INC Brine 0 280
2015 TUSSEL CLARENCE JR Brine 0 0
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2077323677 2003-12-9 0:00: AD No Violations
-22888743 2017-10-30 0:00 EX No Violations
-397259782 2016-5-4 0:00:0 PW No Violations
-547793501 2008-11-4 0:00: PW No Violations
-684830215 2017-4-26 0:00: AD No Violations
0022888743 2017-10-30 Exempt Well Pre Transfer No Violations I inspected this well location as part of on-going efforts by the landowner to acquire the well for exempted domestic use. The transfer of the well from Big Sky Energy to the land owner was previously not approved pending mitigation of some localized oil contamination that had been caused by a leak from the 210-barrel production tank, and impacted areas within the containment berm The landowner had been advised that the transfer would remain pending until the leaking tank was removed and oil-impacted areas mitigated and restored. Subsequent to these findings, the landowner had elected to contract to have the issues resolved. At the time of this inspection, the restoration work was in progress. A new tank pad was being constructed and work to mitigated that oil-impact at the former tank pad was in progress but not completed.
0397259782 2016-05-04 Production Wells Violations Noted My inspection found the tank battery was equipped with one 210 barrel steel tank and one separator. There was oil saturated soil 10 x 5 on south side of the tank, also the ground completely around the tank was oil saturated 1 foot wide. I took two photos of the oil saturated area by the tank. There was no identification posted at the tank battery area. The well was equipped with a plunger lift unit. The valves from the well to the flow line were closed. This well was not in production at the time of my inspection. REQUIRED REMEDIAL WORK: Remove oil saturated area at the tank battery and post identification at the tank battery area.
0547793501 2008-11-04 Production Wells No Violations no violations .
0684830215 2017-04-26 Annular Disposal No Violations My inspection found no annular disposal.
0838233419 2012-03-08 Annular Disposal No Violations no annular disposal .
1470935723 2016-08-10 Exempt Well Pre Transfer No Violations I, along with DOGRM Inspector Flemming, met with the landowner, Mr. Jeff Wuenschel, and inspected the existing well elements as part of an exempt domestic well pre-transfer evaluation. At the time of our inspection, we observed the following: a wellhead with plunger lift system located in an open pasture area, 275 feet SW of the associated tank battery. There was some observed leakage of gas from the production tubing hammer union flange. Fittings and connections at the well were otherwise secure. The associated tank battery was being shared with the Cusano #2 well, which is located 1,800 feet south, on the same parcel. Inspection of the tank battery area revealed the following; one 210-barrel steel production tank and horizontal separator. The production tank exhibited moderate to severe corrosion with several perforations. There was free-phase oil and oil-saturated soils surrounding the base of the tank and extending 15 feet to the south, within the containment berm. I did not observe any signs of oil beyond the limits of the secondary containment. The oil contamination was previously noted by Inspector Kohl, who issued a Compliance Notice on 05/04/2016 pursuant to his inspection on that date. There was no legible identification at the wellhead or battery. The well was not in production at the time of this inspection. Mr. Wuenschel indicated that there was not a current domestic supply connection.
1506090081 2017-09-20 Exempt Well Pre Transfer No Violations NE Region Supervisor and I met with landowner Jeff Wuenschel to inspect and evaluate deficiencies that had previously been noted and were preventing final transfer of the well to the landowner. Specifically, the following issues had been observed: the 210-barrel stock tank was severely corroded and not fit for further use. Crude oil had leaked from several holes in the stock tank resulting in impact to the surface areas within the battery. We advised Mr. Wuesnchel that the existing stock tank must be removed from service and properly disposed. Areas with oil impact must be remediated by removing oil and oil-impacted soils until clean soils were encountered. We further advised that the tank battery must meet the spacing requirements for distance to the neighboring property boundary of 75 feet. We agreed to return and re-inspect to confirm completion of the aforementioned activities.
1510758263 2017-11-15 Exempt Well Pre Transfer No Violations I inspected this well location as part of a transfer of this well to a exempt, domestic owner. Transfer of the well had been pending clean up of oil-impacted soils inside the tank battery, removal of the leaking 210-barrel stock tank, and re-location of the tank battery. At the time of this inspection, the oil-impacted soils had been removed, and the area re-graded. The former 210-barrel stock tank had been removed from the site, and a new battery location had been constructed consisting of a 100-barrel stock tank, located in a earthen-bermed containment. The former mechanical separator was left in place and the interior portion of the containment was cleaned, and re-bermed. Fittings and connections at the wellhead were secure and free from leakage. The battery is shared with the Cuasno #2 well. The transfer of the well to the domestic owner can be completed.
1551107799 2019-02-25 Production Wells No Violations
2065835163 2006-10-20 Production Wells No Violations no violations .
2077323677 2003-12-09 Annular Disposal No Violations No annular disposal .
646653810 2019-5-8 0:00:0 PW No Violations
838233419 2012-3-8 0:00:0 AD No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0397259782 US-OH-124234 2016-07-26 9-1-07 Well operation causing pollution and contamination
0397259782 US-OH-124235 2016-07-26 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]