X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-21222

Well Details

Well ID: 34-007-21222
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Hartsgrove Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: ZGRABIK E & E
License Status: Producing
License Date: 1979-11-27
Spud Date: 1980-01-05
Spud Drilling Contractor:
Final Drill Date: 1980-01-10
Well Total Depth: 3493.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -80.910000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1979-11-27 300 PETROLEUM ENERGY PROD COR GeoDate 11/27/79
Original Spud 1980-01-05 LOG TYPE - X-PLOT
Completed 1980-01-10 LOG TYPE - X-PLOT
Reached Total Depth 1980-01-10 LOG TYPE - X-PLOT
CO 1991-10-09 201 GREEN GAS CO GeoDate 11/27/79
CO 1992-04-09 1453 GREEN ENERGY INC GeoDate 11/27/79
Change of Owner 2001-02-06 Operator changed from 1453, GREEN ENERGY INC to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2013-10-03 LOG TYPE - X-PLOT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3309 3357 16
3309 3357 16
3309 3357 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EVERFLOW EASTERN PARTNERS LP 3368.00 0.00 214
1986 EVERFLOW EASTERN PARTNERS LP 4707.00 0.00 365
1987 EVERFLOW EASTERN PARTNERS LP 3772.00 0.00 365
1988 EVERFLOW EASTERN PARTNERS LP 2339.00 0.00 365
1989 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1990 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1991 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1992 GREEN ENERGY INC 7823.00 0.00 365
1993 GREEN ENERGY INC 7328.00 0.00 365
1994 GREEN ENERGY INC 6696.00 0.00 365
1995 GREEN ENERGY INC 5313.00 0.00 365
1996 GREEN ENERGY INC 6007.00 0.00 365
1997 GREEN ENERGY INC 3949.00 0.00 365
1998 GREEN ENERGY INC 4942.00 0.00 365
1999 GREEN ENERGY INC 4486.00 0.00 365
2000 GREEN ENERGY INC 3731.00 0.00 365
2001 BIG SKY ENERGY INC 1343.00 0.00 365
2002 BIG SKY ENERGY INC 1457.00 0.00 365
2003 BIG SKY ENERGY INC 1455.00 0.00 365
2004 BIG SKY ENERGY INC 2706.00 0.00 365
2005 BIG SKY ENERGY INC 6278.00 0.00 365
2006 BIG SKY ENERGY INC 7704.00 0.00 365
2007 BIG SKY ENERGY INC 2434.00 0.00 365
2008 BIG SKY ENERGY INC 1182.00 0.00 365
2009 BIG SKY ENERGY INC 7227.00 0.00 365
2010 BIG SKY ENERGY INC 7227.00 0.00 365
2011 BIG SKY ENERGY INC 5247.00 0.00 365
2012 BIG SKY ENERGY INC 3468.00 0.00 366
2013 BIG SKY ENERGY INC 1171.00 14.00 365
2014 BIG SKY ENERGY INC 640.00 0.00 365
2016 BIG SKY ENERGY INC 759.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EVERFLOW EASTERN PARTNERS LP Brine 46 214
1986 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1987 EVERFLOW EASTERN PARTNERS LP Brine 94 365
1988 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1989 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1990 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1991 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1992 GREEN ENERGY INC Brine 194 365
1993 GREEN ENERGY INC Brine 193 365
1994 GREEN ENERGY INC Brine 184 365
1995 GREEN ENERGY INC Brine 149 365
1996 GREEN ENERGY INC Brine 77 365
1997 GREEN ENERGY INC Brine 189 365
1998 GREEN ENERGY INC Brine 30 365
1999 GREEN ENERGY INC Brine 79 365
2000 GREEN ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 109 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1154098909 2016-3-9 0:00:0 PW No Violations
-1641484628 2018-5-15 0:00: PW No Violations 1.00
-2001045590 2017-2-17 0:00: PW No Violations
-2105055350 2018-3-6 0:00:0 PW No Violations
-327038660 2015-4-24 0:00: PW No Violations
-80133973 2020-1-9 0:00:0 PW No Violations
0097751885 2017-09-21 Production Wells No Violations I inspected this producing well as a follow-up to a compliance notice that had been issued directing the owner to complete the following: repair defective 4.5-inch well casing that was actively leaking gas, remove stock tank leaking from heater tube, and remove impacted soils. At the time of this inspection I observed the following: there was gas actively leaking from the 4.5-inch well casing as had been previously observed with no evidence of attempts to repair. In addition, the leakage that had been observed from the 210-barrel stock tank remained with no signs or evidence that attempts to mitigate the impacted area had been implemented. The tank remained on location,
0150736574 2015-06-30 Production Wells No Violations My inspection found there has been a attempt to fix the leak from the heater tubes at the base of the production tank. There is still brine dripping from the heater tube at a much slower rate. No other action has been taken to correct the violations.
0246553929 2015-12-02 Production Wells No Violations I conducted an inspection of this well and tank battery and found there was still fluid leaking from the heater tube on the production tank. Pooled fluid had accumulated beneath the heater tube leak. The dike needs rebuilt to prevent escape of any waste or liquids. The signage has been added to the production tank.
0271397011 2016-03-18 Production Wells No Violations I was accompanied by Jen Barret, Dan Martin [ Attorney Generals Office ] and Tom Hill [ ODNR Division of Oil & Gas ]. I took photos of the leaking production tank.
0327038660 2015-04-24 Production Wells No Violations My inspection of the well found there has been no action to remediate the compliance issues. I contacted Don Goosman, he told me they still have no help or a brine truck driver.
0506443716 2015-07-16 Production Wells No Violations My inspection of this well found the permit number on the identification sign at the tank battery location has been posted. The identification at the well location has not been established. There is fluid still dripping onto the ground out of the heater tube. The polluted area at the base of the production tank has not been removed, also a earthen dike has not been established around the production tank.
1046458025 2015-08-03 Production Wells No Violations My inspection of the remedial work found the oil and paraffin at the base of the steel production tank on the north side has been removed. There is still some oil saturated peat sorb remaining. The heater tube was still dripping fluid onto the ground. The fluid was not pooling which indicated the fluid is going below the surface. A earthen dike has not been established around the storage tank. A identification sign has not been posted at the well location.
1087600200 2017-09-12 Production Wells No Violations At the time of my inspection the heating tubes on the 210 barrel production tank were no longer leaking. Fluid level in the tank is now below the heater tubes. The 210 barrel production tank has not been removed and replaced or repaired as required in inspection report dated 04/01/2015. Brine scald is evident under the tank. Soil pollution and contamination is still present under the tank, no action has been taken by the owner to remove the soil, bio-remediate the location if possible or make any effort to correct the issues at the tank battery. The 4.5 inch casing is leaking and has not been repaired as required in the inspection dated 08/31/2016. No action has been taken by the owner to correct the Compliance Notices issued on 04/01/2015 nor the Compliance Notice issued on 08/31/2016.
1099063976 2004-10-29 Production Wells No Violations No violations .
1154098909 2016-03-09 Production Wells No Violations My inspection found no further action has been performed to remediate the pollution at the tank battery area. A earthen dike of sufficient size has not been established around the production tank. There was fluid still leaking from the heater tube at the base of the production tank.
1390214060 2017-11-01 Production Wells No Violations I inspected this well location as part of on-going enforcement proceedings. As such, the following deficiencies had been noted previously: leakage of fluids (oil and brine) from the heater tube located at the bottom of the 210-barrel steel production tank. Leakage of fluid had been observed to impact areas beyond the secondary continament on the north side of the battery. In addition, it had been noted that gas was leaking from the 4.5-inch production casing. At the time of this inspection, I noted the following: a wellhead with plunger lift system and associated battery on a larger, rural parcel. The well is located 200 feet west of the battery. The battery was comprised of one 210-barrel, steel production tank, and horizontal separator. Gas was freely flowing from a failure at the 4.5-inch production casing. It is evident that a previous attempt to repair the leak using a clamp device had failed. There was rust staining at the base of the production tank, near the heater tube location. I did not observe any active fluid leakage from the tank. Subsequent inspection of the tank indicated that there was no visible fluid remaining. The areas of brine scald that had been observed previously on the north side of the tank battery had become overgrown with vegetation, and were no longer visible. The chart recorder was not functioning. There was no visible evidence that any actions had been taken to remediate and/or repair the previously-noted problems and deficiencies.
1428340098 2015-04-01 Production Wells Violations Noted My inspection found fresh oil and brine on the ground at base of steel production tank three feet wide on north, south and west sides. There is fluid leaking from heater tube on west side of the production tank. There is fresh oil on the outside of the production tank on the north side from the top to the base of the tank. The earthen dike around storage tank is not of sufficient size to contain oil and brine stored in the production tank. The wellhead has a active domestic hook-up from the production casing. The identification sign has permit number 1257 posted on it. Permit number 1257 shares tank battery with this well which is permit number 1222. There is no identification posted at the well location. This well is in production at this time. ODNR Division of Oil & Gas records show the last reported production was in 2012 producing 3468 mcf of gas. This well is in non-compliance. Remedial work required to get this well into compliance: EMPTY PRODUCTION TANK IMMEDIATELY, REMOVE CONTAMINATED SOIL AROUND AND UNDER PRODUCTION TANK, REPAIR OR REPLACE LEAKING PRODUCTION TANK, ESTABLISH A EARTHEN DIKE OF SUFFICIENT SIZE TO CONTAIN THE CAPACITY OF THE PRODUCTION TANK, POST PERMIT NUMBER FOR THIS WELL ON IDENTIFICATION SIGN AND POST A IDENTIFICATION SIGN AT WELL LOCATION, SUBMIT PRODUCTION REPORTS FOR THIS WELL FROM 2012 TO PRESENT. I contacted Don Goosman and told him of the violations, he told me as soon as he has equipment he will perform the remedial work.
1436541969 2015-06-09 Production Wells No Violations Northeast Regional Supervisor Tom Hill and I were on location in reference to compliance notice #1428340098. Upon arrival, we found the well tender for Big Sky was on location. During our inspection, we found the contaminated soil on the north side of the 210 barrel tank has not been remediated. The contaminated soil stretches over the north dike wall. An earthen dike of sufficient size has not been built. I observed fresh oil still on the outside of the 210 barrel production tank on the north side from the top to the base of the tank. Rudder caps with hose clamps have been installed on the heating tubes. While on site, I told the well tender the highly faded identification sign needed updated with the correct permit number. The well tender obtained a black marker from his vehicle and corrected the entire identification sign. Next, we told the well tender that:



The well tender stated Big Sky was waiting on a part to finish repairs on the backhoe. Follow-up inspection will continue until all violations are corrected.

1441794244 2015-08-19 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1428340098. During my inspection, I found the impacted soil around the 210 barrel tank scrapped up and removed. There are two rubber caps on the heating tubes. An identification sign is posted.
1446489887 2015-11-02 Production Wells No Violations My inspection found there was still fluid leaking from the heater tube for the storage tank. There was salt crystals on the ground underneath the leaking heater tube. There has not been a earthen dike of sufficient size established around the storage tank. There was no identification posted at the well location.
1472658445 2016-08-26 Production Wells Violations Noted On site with DOGRM Inspector Mike Dinsmore at the time of my inspection the 210 barrel production tank was continuing to leak at the heater tubes. The rate of leak has slowed since last site inspection, the tank is nearly empty. There was iron staining 3 feet in diameter around the heater tubes that was leaking. Rubber caps the operator has placed on the heater tubes were still in place. The well was shut in. The 4.5 inch casing has a metal clamp on it above the Braden head. The clamp has failed; the well was releasing gas from the 4.5 inch casing at a vigorous rate from behind the clamp. The following remedial action needs to take place at the location: 210 barrel production tank shall be removed and replaced. All contaminated soil from under the tank shall be removed and properly disposed of. Division shall receive disposal tickets from where the material is disposed of. The 4.5 inch production case shall be repaired in order to stop the uncontrolled release of gas into the environment.
1483981264 2016-12-27 Production Wells No Violations My inspection of this well found there has been no remedial work done to resolve the compliance issues with this well. The gas leak at well that was noted on a report by Tom Hill on 8-26-2016 has been corrected. I took one photo of the scalded area at the base of the production tank on the west side.
150736574 2015-6-30 0:00: PW No Violations
1548876429 2019-01-30 Production Wells No Violations
1598013874 2020-8-20 0:00: PW No Violations
1641484628 2018-05-15 Production Wells No Violations I inspected this well location as part of open compliance violations. As such, the following deficiencies had been noted previously: leakage of fluids (oil and brine) from the heater tube located at the bottom of the 210-barrel steel production tank. Leakage of fluid had been observed to impact areas beyond the secondary continament on the north side of the battery. In addition, it had been noted that gas was leaking from the 4.5-inch production casing. At the time of this inspection, I noted the following: Gas was freely flowing from a failure at the 4.5-inch production casing. There was rust staining at the base of the production tank, near the heater tube location. I did not observe any active fluid leakage from the tank. Subsequent inspection of the tank indicated that there was no visible fluid remaining. The chart recorder was not functioning. There was no visible evidence that any actions had been taken to remediate and/or repair the previously-noted problems and deficiencies.
1712151443 2015-06-11 Production Wells No Violations Myself, Tom Hill and Terry Whitehair inspected the violations to find the 210 barrel steel tank is still leaking brine from the heater tube. There has been no action to correct any of the violations.
2001045590 2017-02-17 Production Wells No Violations Myself, Tom Hill, Rick Anderson, Terry Whitehair and Gene Park with ODNR Division of Oil & Gas met with Bob Barr Sr., Charles Mosio and Gino Pulito with Big Sky Energy on site to discuss the required remedial work needed to comply with the compliance issues with this well.
2105055350 2018-03-06 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 14283440098. At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The 4.5 inch casing leak was repaired with a clamp. The tank battery consisted of one 210 BBL production tank and a mechanical separator. The dike around the tank battery still needs rebuilt and the impacted soil within the battery still needs to be cleaned up and remedied. Signage has not been updated at the well or tank battery location.
246553929 2015-12-2 0:00: PW No Violations
271397011 2016-3-18 0:00: PW No Violations
506443716 2015-7-16 0:00: PW No Violations
97751885 2017-9-21 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1428340098 US-OH-112504 2015-04-14 Well operation causing pollution and contamination
1428340098 US-OH-112505 2015-04-14 Failure to legibly identify well
1428340098 US-OH-112506 2015-04-14 No SPCC dike/or failure to keep dike free of water or oil
1428340098 US-OH-112507 2015-04-14 Statement of annual production not filed
1472658445 US-OH-113577 2017-06-08 Defective casing, leaking well

For data sources see[9]