34-007-20810

Well Details

Well ID: 34-007-20810
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Lenox Township
Operator Name: BOCOR HOLDINGS, LLC
Well Pad ID:
Farm/Lease Name: FAILE UNIT
License Status: Producing
License Date: 2007-07-26
Spud Date: 1978-07-15
Spud Drilling Contractor:
Final Drill Date: 1978-07-28
Well Total Depth: 3676.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completion Report Received 1978-03-12 R.I. 6-28-78
CO 1978-06-20 3394 YO-11 CORP GeoDate 6/20/78
Oil and Gas 1978-06-20 Issued Date 6/20/78 Expired Date Acres 0160000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1978-07-15 R.I. 6-28-78
Completed 1978-07-28 R.I. 6-28-78
Reached Total Depth 1978-07-28 R.I. 6-28-78
Change of Owner 1998-08-14 Operator changed from 3394, YO-11 CORP to 3954, WILKES ENERGY INC
Change of Owner 2001-10-10 Operator changed from 3954, WILKES ENERGY INC to 6805, GAS ACQUISITION COMPANY LTD
APP 2007-07-26 Proposed Formations:CLINTON, Issued Date:7/26/2007, Expired Date:7/25/2008 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Change of Owner 2008-07-03 Operator changed from 6805, GAS ACQUISITION COMPANY LTD to 935, BOCOR HOLDINGS, LLC/BOCOR PROD
Construction Permit Expires 2008-07-25 R.I. 6-28-78
Record Last Modified 2017-02-15 R.I. 6-28-78

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1999-03-12 3542 3634 22
3542 3634 22
3542 3634 22

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 80000 Gal 72000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1998 WILKES ENERGY INC 94.00 22.00 90
1999 WILKES ENERGY INC 626.00 180.00 330
0 0 0
2004 GAS ACQUISITION COMPANY LTD 413.00 32.00 365
2009 BOCOR HOLDINGS, LLC 73.00 0.00 53
2012 BOCOR HOLDINGS, LLC 404.00 106.00 366
2013 BOCOR HOLDINGS, LLC 532.00 70.00 365
2014 BOCOR HOLDINGS, LLC 434.00 63.00 365
2015 BOCOR HOLDINGS, LLC 1042.00 85.00 356
2016 BOCOR HOLDINGS, LLC 1129.00 112.00 365
2017 BOCOR HOLDINGS, LLC 775.00 127.00 365
2018 BOCOR HOLDINGS, LLC 536.00 76.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1998 WILKES ENERGY INC Brine 0 90
1999 WILKES ENERGY INC Brine 20 330
2004 GAS ACQUISITION COMPANY LTD Brine 0 365
2009 BOCOR HOLDINGS, LLC Brine 0 53
2012 BOCOR HOLDINGS, LLC Brine 272 366
2013 BOCOR HOLDINGS, LLC Brine 163 365
2014 BOCOR HOLDINGS, LLC Brine 168 365
2015 BOCOR HOLDINGS, LLC Brine 229 356
2016 BOCOR HOLDINGS, LLC Brine 265 365
2017 BOCOR HOLDINGS, LLC Brine 243 365
2018 BOCOR HOLDINGS, LLC Brine 185 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1454651783 2019-5-23 0:00: PW No Violations
0624030620 2018-12-14 Production Wells Violations Noted I conducted an inspection this well. The well was equipped with a pumping unit and in production at the time of this inspection. The tank battery was comprised of one 210 BBL tank, one 100 BBL tank and a mechanical separator. Valves on the separator were open. The diked tank battery contained legible identification and was shared with wells 2-0809, 2-0811, and 2-0812. The lease access was stable. Due to a shared battery with multiple wells, identification needs added to the well location per OAC 1501:9-9-05(A)10. I contacted Todd Suko of Bocor Holding, LLC regarding the installation of identification at the well location.
0886561931 2006-04-18 Production Wells No Violations no violations .
1555341177 2019-04-15 Production Wells No Violations I conducted a compliance notice follow-up. At the time of my inspection the well is equipped with an electric pump jack unite. The production valve was open at well. The tank battery consisted of one 100- barrel production tank, one 210-barrel production tank, and a mechanical separator. The load line to the tanks production valve was secured with a plug. An earthen dike surrounded the tank battery. Proper identification was posted at the tank battery. The lease road was in stable condition. Production records are current. There was no identification at well location. Compliance has not yet been taken care of.
624030620 2018-12-14 0:00 PW No Violations
886561931 2006-4-18 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0624030620 US-OH-127053 2019-01-14 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]