Well Details

Well ID: 34-007-20682
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Sheffield Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: WESTCOTT P & M
License Status: Producing
License Date: 1975-07-03
Spud Date: 1975-07-07
Spud Drilling Contractor:
Final Drill Date: 1976-12-15
Well Total Depth: 3313.00 ft
Configuration: Vertical
Latitude: 41.840000
Longitude: -80.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1975-07-03 300 PETROLEUM ENERGY PROD COR GeoDate 7/3/75
Oil and Gas 1975-07-03 Issued Date 7/3/75 Expired Date Acres 0042330 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1975-07-07
Completed 1976-12-15
Reached Total Depth 1976-12-15
Completion Report Received 1977-07-07
CO 1991-10-09 201 GREEN GAS CO GeoDate 7/3/75
CO 1992-04-09 1453 GREEN ENERGY INC GeoDate 7/3/75
Change of Owner 2001-02-07 Operator changed from 1453, GREEN ENERGY INC to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3131 3138 14
2006-09-11 3094 3099 5
3094 3099 5
3094 3099 5
2006-09-11 3171 3173 2
2006-09-11 3149 3152 3

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2000 Bbl 60000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 EVERFLOW EASTERN PARTNERS LP 1216.00 0.00 214
1986 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1987 EVERFLOW EASTERN PARTNERS LP 51.00 0.00 365
1988 EVERFLOW EASTERN PARTNERS LP 144.00 0.00 365
1989 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1990 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1991 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1992 GREEN ENERGY INC 4585.00 60.00 365
1993 GREEN ENERGY INC 3382.00 0.00 365
1994 GREEN ENERGY INC 3015.00 79.00 365
1995 GREEN ENERGY INC 2947.00 60.00 365
1996 GREEN ENERGY INC 2345.00 0.00 365
1997 GREEN ENERGY INC 2058.00 59.00 365
1998 GREEN ENERGY INC 1514.00 0.00 365
1999 GREEN ENERGY INC 1099.00 0.00 365
2000 GREEN ENERGY INC 587.00 13.00 365
2001 BIG SKY ENERGY INC 467.00 0.00 365
2002 BIG SKY ENERGY INC 501.00 118.00 365
2003 BIG SKY ENERGY INC 413.00 0.00 365
2004 BIG SKY ENERGY INC 895.00 0.00 365
2005 BIG SKY ENERGY INC 408.00 25.00 365
2006 BIG SKY ENERGY INC 237.00 0.00 365
2007 BIG SKY ENERGY INC 175.00 5.00 365
2008 BIG SKY ENERGY INC 33.00 0.00 365
2009 BIG SKY ENERGY INC 22.00 18.00 365
2010 BIG SKY ENERGY INC 112.00 19.00 365
2011 BIG SKY ENERGY INC 25.00 0.00 365
2012 BIG SKY ENERGY INC 298.00 0.00 366
2013 BIG SKY ENERGY INC 248.00 0.00 250
2014 BIG SKY ENERGY INC 25.00 0.00 365
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 EVERFLOW EASTERN PARTNERS LP Brine 0 214
1986 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1987 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1988 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1989 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1990 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1991 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1992 GREEN ENERGY INC Brine 1032 365
1993 GREEN ENERGY INC Brine 679 365
1994 GREEN ENERGY INC Brine 616 365
1995 GREEN ENERGY INC Brine 547 365
1996 GREEN ENERGY INC Brine 398 365
1997 GREEN ENERGY INC Brine 76 365
1998 GREEN ENERGY INC Brine 520 365
1999 GREEN ENERGY INC Brine 411 365
2000 GREEN ENERGY INC Brine 215 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 250
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1052514680 2006-9-25 0:00: PW No Violations
-1220607344 2016-5-9 0:00:0 PW No Violations
-1248067337 2007-5-16 0:00: PW No Violations
-1430204652 2006-10-20 0:00 PW No Violations
-1460403889 2018-12-13 0:00 PW No Violations
-1628414331 2006-11-13 0:00 PW No Violations
-1747140146 2018-3-7 0:00:0 PW No Violations
-200428055 2006-9-29 0:00: PW No Violations
-451391498 2006-10-3 0:00: PW No Violations
-858419644 2016-12-8 0:00: PW No Violations
0051333819 2018-08-01 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1220607344 and complaint # 5544. At the time of this inspection, the well was equipped with a pumpjack and the 2 inch flow lines off of the tubing and casing were closed. There was a small audible leak on the tubing below the stuffing box. The tank battery consisted of one 210 BBL production tank and a mechanical separator inside the diked tank battery. There was also a 210 BBL tank outside of the diked battery and disconnected from the other production equipment. The oil impacted area inside the diked tank battery has not been cleaned up. The tank battery was shared with well 2-0682. No signage has been added at the well or tank battery locations. No changes have occurred since the last inspection on 3/7/2018.
0200428055 2006-09-29 Production Wells No Violations More clean-up is needed .
0451391498 2006-10-03 Production Wells No Violations Final clean-up is not completed .
0574080842 2006-09-22 Production Wells No Violations Clean-up is ongoing .
0858419644 2016-12-08 Production Wells No Violations Myself and Tom Hill inspected this well to find the company has not performed the remediation to resolve the compliance notice. Tom took photos of the tank pad area.
1052514680 2006-09-25 Production Wells No Violations More clean-up is needed .
1185451042 2007-06-25 Production Wells No Violations Case# 07-003 . Inspection showed remedial work has been completed . NO VIOLATIONS , RESOLVED .
1220607344 2016-05-09 Production Wells Violations Noted My inspection found the tank battery was equipped with one 210 barrel steel tank and one separator. There was one 210 barrel steel tank on the south side of the earthen dike area. The tank was not connected to anything. There was no information posted on the identification sign at the tank battery area. There was fresh oil pooled on the east side of the tank in area of ten feet in diameter inside the earthen dike area. I took two photos of the pooled oil at the tank battery area. The well was equipped with a pumping unit. The motor on the pump-jack was missing. This well shares a common tank battery with permit# 894. There was no identification posted at the well location. The valves from the well to the flow line were closed. This well was not in production at the time of my inspection. REQUIRED REMEDIAL WORK: Remove all oil and oil saturated material from the tank battery area, post identification at the tank battery and well locations.
1248067337 2007-05-16 Production Wells Violations Noted Case# 07-003 , Linda Hochschild . Inspection showed there were small areas that oil had soaked through soil from earlier oil spill clean-up earlier in the year .
1430204652 2006-10-20 Production Wells No Violations There is soil stockpiled on site , soil needs to be removed .
1440192128 2017-02-17 Production Wells No Violations Myself, Tom Hill, Rick Anderson, Terry Whitehair and Gene Park with ODNR Division of Oil & Gas met with Bob Barr Sr., Charles Mosio and Gino Pulito with Big Sky Energy on site to discuss the required remedial work needed to comply with the compliance issues with this well.
1460403889 2018-12-13 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1220607344 and complaint #5544. I received a call from landowner Linda Hochscild stating that there was a gas leak at the well location. At the time of this inspection, the stuffing box on the pumping unit at the well had an audible gas leak. No fluid was leaking from the well, only gas. I contacted well tender Charles Moisio about the leak. Mr. Moisio stated he would be on location today to repair the leaking stuffing box. The tank battery consisted of one 210 BBL production tank and a mechanical separator inside the diked tank battery. There was also a 210 BBL tank outside of the diked battery and disconnected from the other production equipment. The oil impacted area inside the diked tank battery has not been cleaned up. The tank battery was shared with well 2-0894. Identification still has not been added at the well or tank battery locations. I contacted the landowner after receiving a follow-up phone call from Mr. Moisio that the stuffing box leak had been repaired.
1496671361 2017-03-29 Production Wells No Violations Complaint# 5544, Linda Hochscild. My inspection found this well was shut-in at the wellhead. There was no domestic gas use from this well. I contacted Linda and told her of my findings. NOTE: There are pending compliance issues with this well which have not been resolved. There are no new compliance issues with this well.
1563758207 2019-7-1 0:00:0 PW No Violations
1625158329 2018-10-01 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1220607344 and complaint #5544. At the time of this inspection, the well was equipped with a pumping unit and the annulus and flow line valves were closed. The tank battery consisted of one 210 BBL production tank and a mechanical separator inside the diked tank battery. There was also a 210 BBL tank outside of the diked battery and disconnected from the other production equipment. The oil impacted area inside the diked tank battery has not been cleaned up. The tank battery was shared with well 2-0894. No signage has been added at the well or tank battery locations.

Big Sky needs to: 1) Remove the disconnected 210 BBL tank outside of the tank battery 2) Cleanup and remove any oil impacted soil inside the tank battery 3) Install legible identification at the well site

1628414331 2006-11-13 Production Wells No Violations Case# 06-014 , Linda Hochschild . Remedial work has been completed , no violations , RESOLVED .
1747140146 2018-03-07 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1220607344. At the time of this inspection, the well was equipped with a pumpjack and the annulus and flow line valves were closed. The tank battery consisted of one 210 BBL production tank and a mechanical separator inside the diked tank battery. There was also a 210 BBL tank outside of the diked battery and disconnected from the other production equipment. The oil impacted area inside the diked tank battery has not been cleaned up. The tank battery was shared with well 2-0894. No signage has been added at the well or tank battery locations.
2032784141 2006-09-21 Production Wells Violations Noted Case# 06-014 , Linda Hochschild . Inspection showed production tank had overflowed causing approx. 5 gal. Of oil to flow approx. 40 toward road ditch . Company had been on site . They placed oil sorb over spill area . Oil is contained at this time .
51333819 2018-8-1 0:00:0 PW No Violations
574080842 2006-9-22 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1220607344 US-OH-105907 2016-07-26 9-1-07 Well operation causing pollution and contamination
1220607344 US-OH-105908 2016-07-26 9-9-05(A)10 Failure to legibly identify well
1248067337 US-OH-106604 2007-06-21 Well operation causing pollution and contamination
2032784141 US-OH-120663 2006-12-14 Well operation causing pollution and contamination

For data sources see[9]

References