34-007-20575

Well Details

Well ID: 34-007-20575
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Plymouth Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: GALOVICH F & M UNIT
License Status: Producing
License Date: 1980-08-02
Spud Date: 1973-08-26
Spud Drilling Contractor:
Final Drill Date: 1973-09-04
Well Total Depth: 3130.00 ft
Configuration: Vertical
Latitude: 41.850000
Longitude: -80.740000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1973-08-26
Completed 1973-09-04
Reached Total Depth 1973-09-04
CO 1980-08-02 254 EDCO DRILLING & PRODUCING GeoDate 8/2/80
Oil and Gas 1980-08-02 Issued Date 8/2/80 Expired Date Acres 0160000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Change of Owner 2016-04-27 Operator changed from 254, EDCO DRILLING & PRODUCING to 1333, BIG SKY ENERGY INC - WELL TRANSFERRED TO BIG SKY FROM CHANGE OF OWNER FORM 7 DATED 2/1999 PER LEGAL EMAIL DATED 4/26/2016 ON 4/27/2016 CM.
Record Last Modified 2016-04-27

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 2916 3000 0
2916 3000 0
2916 3000 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 65000 Gal 75000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 EDCO DRILLING & PRODUCING 6363.00 0.00 90
1987 EDCO DRILLING & PRODUCING 7529.00 174.00 365
1988 EDCO DRILLING & PRODUCING 4134.00 90.00 335
1989 EDCO DRILLING & PRODUCING 2678.00 95.00 365
1991 EDCO DRILLING & PRODUCING 2077.00 74.00 365
1992 EDCO DRILLING & PRODUCING 1831.00 0.00 365
1993 ATWOOD RESOURCES INC 0.00 0.00 0
1994 MERIDIAN ENERGY COMPANY 1317.00 82.00 365
1995 MERIDIAN ENERGY COMPANY 1268.00 0.00 365
1996 MERIDIAN ENERGY COMPANY 1286.00 25.00 365
1997 MERIDIAN ENERGY COMPANY 953.00 0.00 365
1999 MERIDIAN ENERGY COMPANY 1382.00 0.00 365
2000 MERIDIAN ENERGY COMPANY 1644.00 29.00 365
2001 BIG SKY ENERGY INC 748.00 0.00 365
2002 MERIDIAN ENERGY COMPANY 0.00 22.00 365
2003 MERIDIAN ENERGY COMPANY 0.00 0.00 365
2004 MERIDIAN ENERGY COMPANY 0.00 0.00 0
2005 MERIDIAN ENERGY COMPANY 582.00 0.00 365
2006 MERIDIAN ENERGY COMPANY 1207.00 0.00 365
2007 MERIDIAN ENERGY COMPANY 2063.00 91.00 365
2008 MERIDIAN ENERGY COMPANY 2807.00 168.00 365
2009 MERIDIAN ENERGY COMPANY 2151.00 0.00 365
2010 MERIDIAN ENERGY COMPANY 1876.00 0.00 365
2011 BIG SKY ENERGY INC 822.00 77.00 365
2012 BIG SKY ENERGY INC 502.00 0.00 365
2013 BIG SKY ENERGY INC 394.00 29.00 300
2014 BIG SKY ENERGY INC 346.00 0.00 300
2016 BIG SKY ENERGY INC 0.00 0.00 0
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 EDCO DRILLING & PRODUCING Brine 776 90
1987 EDCO DRILLING & PRODUCING Brine 1410 365
1988 EDCO DRILLING & PRODUCING Brine 992 335
1989 EDCO DRILLING & PRODUCING Brine 549 365
1991 EDCO DRILLING & PRODUCING Brine 169 365
1992 EDCO DRILLING & PRODUCING Brine 476 365
1993 ATWOOD RESOURCES INC Brine 0 0
1994 MERIDIAN ENERGY COMPANY Brine 358 365
1995 MERIDIAN ENERGY COMPANY Brine 212 365
1996 MERIDIAN ENERGY COMPANY Brine 269 365
1997 MERIDIAN ENERGY COMPANY Brine 310 365
1999 MERIDIAN ENERGY COMPANY Brine 94 365
2000 MERIDIAN ENERGY COMPANY Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 MERIDIAN ENERGY COMPANY Brine 0 365
2003 MERIDIAN ENERGY COMPANY Brine 0 365
2004 MERIDIAN ENERGY COMPANY Brine 0 0
2005 MERIDIAN ENERGY COMPANY Brine 0 365
2006 MERIDIAN ENERGY COMPANY Brine 0 365
2007 MERIDIAN ENERGY COMPANY Brine 0 365
2008 MERIDIAN ENERGY COMPANY Brine 0 365
2009 MERIDIAN ENERGY COMPANY Brine 0 365
2010 MERIDIAN ENERGY COMPANY Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 365
2013 BIG SKY ENERGY INC Brine 348 300
2014 BIG SKY ENERGY INC Brine 0 300
2016 BIG SKY ENERGY INC Brine 0 0
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1017679487 2015-4-1 0:00:0 PW No Violations
-1651344287 2017-10-31 0:00 PW No Violations 1.00
-1891504030 2016-8-26 0:00: PW No Violations
-2040369653 2004-6-24 0:00: PL No Violations
-2096280729 2015-7-9 0:00:0 PW No Violations
-303692777 2015-6-10 0:00: PW No Violations
-35714722 2003-8-18 0:00: PL No Violations
-470195101 2004-6-24 0:00: PL No Violations
-655809611 2004-9-27 0:00: PW No Violations
-697787108 2015-7-21 0:00: PW No Violations
-732500371 2003-12-9 0:00: PL No Violations
0035714722 2003-08-18 Preliminary Restoration Violations Noted Case# 03-018 , Debbie Friedstrom , Inspection showed area flowline was replaced around tank battery and flowline route needed final grading and establish vegetation . I could not locate any gas leaks at this time . REMEDIAL REQUIRED ; final grade flowline area and establish vegetation .
0296554513 2016-03-09 Production Wells No Violations My inspection found there has been no further remedial work performed since my last inspection on 10-29-2015.
0303692777 2015-06-10 Production Wells Violations Noted Follow-up, Complaint# 4986, Debbie Friedstrom. Myself and Tom Hill inspected the well to find there was fresh oil lying on the ground and floating on water lying at the north end of the tank battery area, also there is a new gas leak located at the north-east corner of the separator. The identification has not been posted at the tank battery area. Tom contacted Bob Barr Sr. and told him of the oil spill and the gas leak. A new compliance was issued for the oil spill and the gas leak.
0305567209 2015-08-20 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 2057909685. During my inspection, I observed a pool of oil at the north end of the tank battery next to the separator. There are used absorbent pad lying throughout the tank battery. The entire tank battery is stained with oil. I found five (5), oil stained, 5 gallon buckets with lids sitting next to the production tank. There is a 2 load line missing a plug. An identification sign is posted a production tank with no permit number. There is a Kubota excavator sitting on location next to the tank battery.
0385346818 2016-03-18 Production Wells No Violations I was accompanied by Jen Barret, Dan Martin, Mike Williams [ Attorney Generals Office ], Rick Anderson and Tom Hill [ODNR Division o Oil & Gas ]. Upon our arrival we found that the earthen dike had been breached on the north-east corner allowing the fluid inside the earthen dike walls to drain from the tank battery area into a crop field. I tested the remaining fluid inside the dike and in the crop field where the fluid had flowed with 1176 qauntab strips to find the chloride levels exceeded the limits of the chloride strips which was 6300 ppm chlorides. There was a new chart on the gas meter with the date of 3-10-2016 wrote on it. The chart indicated the well was in production at the time of the inspection. I took photos of the ditch in the earthen dike wall and inside the earthen dike walls.
0470195101 2004-06-24 Preliminary Restoration Violations Noted Case# 03-018 . Remedial not complete .
0633005652 2018-02-27 Production Wells No Violations I, along with Supervisor Tom Hill, inspected this well location as part of on-going enforcement proceedings. As such, the following deficiencies had been noted previously: leakage of oil within the battery and lack of complete identifying signage. At the time of this inspection, we noted the following: a wellhead with plunger lift system and associated battery on a larger, rural parcel. The battery was comprised of two 100-barrel, steel production tanks, and horizontal separator. Fittings and connections at the wellhead were secure. There was oil and oil-stained ballast material throughout most of the tank containment area that remained from a prior release and had not been addressed. The chart box was not active and the well was not in production. The signage was faded and not legible. There had been no apparent effort to rectify the aforementioned deficiencies.
0655809611 2004-09-27 Production Wells No Violations Remedial work has been completed .
0697787108 2015-07-21 Production Wells No Violations Follow-up: Complaint# 4986, Debbie Freidstrom. My inspection found the free fluid has been removed from inside the earthen dike area. There is still fresh oil saturated gravel and soil inside the earthen dike area. There is still a active gas leak on the east side of the separator.
0732500371 2003-12-09 Preliminary Restoration Violations Noted Case# 03-018 , Debbie Friedstrom . Inspection showed remedial work has not been completed at this time . Conf. With Bob Barr , he advised me it hasnt been dry enough to grade without causing more damage . I advised Bob to watch the weather more closely and perform remedial work the first chance the weather permits .
0832255185 2015-06-30 Production Wells No Violations Follow-up, complaint# 4986, Debbie Freidstrom. My inspection found there has been no change in the correction of the violations since the last inspection on 6-16-2015.
1017679487 2015-04-01 Production Wells No Violations Complaint# 4986 follow-up. I arrived at the gas leak location to find the gas is still leaking from the gas line. I contacted Don Goosman, he told me he had shut-in the line. He will investigate to determine how to shut the gas supply to the gas line off.
1234546194 2016-12-08 Production Wells No Violations Myself and Tom Hill inspected this well to find the company has not performed the remediation to resolve the compliance notice. Tom took photos of the tank pad area.
1254311537 2015-04-24 Production Wells No Violations Follow-up, Complaint# 4986, Debbie Friedstrom. The gas leak has not been repaired. I contacted Bob Barr Sr., he told me they attempted to repair the leak but the repairs did not hold. He then said he did not believe the gas line was his line. I told him I would make some calls to determine who owns the gas line. I traveled northeast of the leaking gas line off of State road and found a gas line owned by Dominion Gas Company and a gas line which was marked with a gas line marker showing C-Gas as the owner. There was two gate valves by the gas line marker owned by C-Gas. I contacted Dominion Gas, I spoke with Jeff Baker, he told me the line they owned off of State road was a 12 high pressure line and there were no gas wells in the area connected to the gas line. I then contacted Ken Kraeger , he was employed by C-Gas in the past and had knowledge of the gas line off of State road. He told me the gas line was sold to Big Sky with wells in the area. He said the gate valves I found was to a gas line that used to supply two factorys in Ashtabula City which have since gone out of business. Upon my request he voluntarily checked the gate valves to determine if they were closed. Don Kreager contacted me later in the day and told me the valves were open. He closed both valves which were four inch valves. I then contacted Don Goosman and told him of my findings of the gas line ownership and closing of the valves off of State road.
1344062711 2019-12-13 0:00 PW No Violations
1431102283 2015-04-22 Production Wells No Violations Follow-up, Complaint# 4986, Debbie Freidstrom. There is still gas leaking from gas line. I contacted Don Grossman, he told me they are waiting for repairs to their track hoe to fix the gas leak.
1431358658 2015-04-28 Production Wells No Violations Follow-up, Complaint# 4986, Debbie Friedstrom. Inspection of the gas leak found the line has been covered. There was no sign of the line leaking gas. The identification has not been established and the well is not in production. I contacted Don Goosman, he told me they were able to repair the leaking gas line.
1436796794 2015-06-16 Production Wells No Violations Follow-up complaint# 4986, Debbie Friedstrom. My inspection of the violations found there is still a active gas leak inside the earthen dike area on the east side of the separator. There is fresh oil floating on the water inside the earthen dike walls over 70 percent of the area inside the earthen dike walls. The identification for this well has not been posted at the tank battery area.
1446468389 2015-10-29 Production Wells No Violations My inspection found fluid has accumulated in the north end of the dike area, covering one third of the area inside the earthen dike walls and was about eight inches deep. The gravel inside the earthen dike walls was oil saturated about 80 percent of the area. There was gas still leaking from below the surface at the north-east corner of the dike area, two feet east of the separator.
1449846632 2015-12-02 Production Wells No Violations I conducted an inspection on this well and tank battery and found oily water accumulated within the north end of the dike area approximately six-to-eight inches deep. The gravel inside the dike was approximately 80 to 90 percent oil saturated. I observed five sealed 5 gallon buckets next to the production tank, within the dike present at the time of this inspection. Gas was still leaking from below the surface at the north-east corner of the dike. The wellhead valves were open. No issues at wellhead.
1487786021 2017-02-17 Production Wells No Violations Myself, Tom Hill, Rick Anderson, Terry Whitehair and Gene Park with ODNR Division of Oil & Gas met with Bob Barr Sr., Charles Mosio and Gino Pulito with Big Sky Energy on site to discuss the required remedial work needed to comply with the compliance issues with this well.
1505222054 2017-07-21 Production Wells No Violations At the time of my inspection no effort had been made to remediate the tank battery. Oil staining was still present along the east side of the tank battery. Brine and iron staining was still present on the north end of the battery. All but the northern most end of the battery was dry.
1526392105 2018-05-15 UrbanProduction Wells No Violations I inspected this well location as part of evaluation of current condition relative to open compliance notice. As such, the following deficiencies had been noted previously: leakage of oil within the battery and lack of complete identifying signage. At the time of this inspection, I noted the following: a wellhead with plunger lift system and associated battery on a larger, rural parcel. The battery was comprised of two 100-barrel, steel production tanks, and horizontal separator. Fittings and connections at the wellhead were secure. There were several inches of standing water in the secondary containment, with a visible floating sheen of oil, and free oil was released from the underlying gravel ballast material when disturbed. The chart box was not active and the well was not in production. The signage was faded and not legible. There were no indications that any efforts to mitigate, clean-up, or fix the noted deficiencies had been undertaken.
1598277392 2020-8-24 0:00: PW No Violations
1598932762 2015-06-11 Production Wells No Violations Follow-up, Complaint# 4986, Debbie Friedstrom. Myself, Tom Hill and Terry Whitehair inspected the violations to find no action has been taken to correct them.
1651344287 2017-10-31 Production Wells No Violations I inspected this well location as part of on-going enforcement proceedings. As such, the following deficiencies had been noted previously: leakage of oil within the battery and lack of complete identifying signage. At the time of this inspection, I noted the following: a wellhead with plunger lift system and associated battery on a larger, rural parcel. The battery was comprised of two 100-barrel, steel production tanks, and horizontal separator. Fittings and connections at the wellhead were secure. There was oil and oil-stained ballast material throughout most of the tank containment area. Some of the oil appeared to be aged and degraded with evidence of newer oil leakage. I did not observe any leaking gas at the well, battery, or along the flow-line or sales line pathways. I noted the chart box was not active. The signage was faded and not legible. There had been no apparent effort to rectify the aforementioned deficiencies.
1891504030 2016-08-26 Production Wells No Violations On site with DOGRM Inspector Mike Dinsmore to check the status of the tank battery. Brine and free crude oil remain at the north end of the tank battery. Five gallon buckets of oil coated stone still remain in the battery. Oil stained and oil soaked soil and gravel remain in the center of the battery. No gas leaking next to the separator was noted at the time of this inspection. Chart in the chart box was illegible.
1937822235 2011-05-26 Production Wells No Violations no violations .
2040369653 2004-06-24 Preliminary Restoration Violations Noted Remedial work not completed .
2057909685 2015-03-31 Production Wells Violations Noted Complaint# 4986, Debbie Friedstrom. I met with Chris Brockway at the tank battery location. We walked to the gas leak location, 500 south of tank battery area and 10 east of Freedom lane. There was a hole two feet in diameter which was full of fluid with gas venting through fluid at a constant rate. I contacted Don Goosman with Big Sky Energy. I told him of the gas leak, he told me he had no equipment to repair the leak right now but he would come out immediately to shut-in the gas line. This well is not in production at this time. ODNR Division of Oil & Gas records show the last reported production was in 2010, producing 1876 mcf of gas. Also the identification sign has no information posted on it. This well is in non-compliance. Remedial work required to get well into compliance: REPAIR GAS LEAK, POST CORRECT INFORMATION ON IDENTIFICATION SIGN, SUBMIT PRODUCTION REPORTS FROM 2010 TO PRESENT, PLUG WELL.
2096280729 2015-07-09 Production Wells No Violations Follow-up, complaint# 4986, Debbie Freidstrom. My inspection found there is still a active gas leak at the tank battery area, also the oil inside the earthen dike area has not been removed. Identification has been posted at the tank battery area.
296554513 2016-3-9 0:00:0 PW No Violations
305567209 2015-8-20 0:00: PW No Violations 0.70
385346818 2016-3-18 0:00: PW No Violations
633005652 2018-2-27 0:00: PW No Violations 0.50
832255185 2015-6-30 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0035714722 US-OH-123756 2003-09-30 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
0303692777 US-OH-123166 2015-07-06 Inadequate pipeline strength
0303692777 US-OH-123167 2015-07-06 Well operation causing pollution and contamination
0470195101 US-OH-125097 2004-10-26 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
0732500371 US-OH-128331 2003-12-15 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
2040369653 US-OH-120754 2004-10-26 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
2057909685 US-OH-120960 2015-04-14 Inadequate pipeline strength
2057909685 US-OH-120961 2015-04-14 Failure to legibly identify well
2057909685 US-OH-120962 2015-04-14 Well shall be plugged

For data sources see[9]