X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-20289

Well Details

Well ID: 34-007-20289
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: New Lyme Township
Operator Name: C & D OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: BROCKWAY LAWRENCE L& MARION
License Status: Producing
License Date: 1970-04-20
Spud Date: 1970-04-19
Spud Drilling Contractor:
Final Drill Date: 1970-04-26
Well Total Depth: 3527.00 ft
Configuration: Vertical
Latitude: 41.640000
Longitude: -80.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1970-04-19
CO 1970-04-20 399 CHANSE PETROLEUM CORP GeoDate 4/20/70
Oil and Gas 1970-04-20 Issued Date 4/20/70 Expired Date Acres 0080000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Completed 1970-04-26
Reached Total Depth 1970-04-26
Change of Owner 2000-06-02 Operator changed from 399, CORNER OPERATING COMPANY, INC to 5952, BELVOIR ENERGY INC.
Change of Owner 2018-02-12 Operator changed from 5952, BELVOIR ENERGY INC. to 10067, C & D OIL & GAS LLC
Record Last Modified 2018-02-12

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3364 3490 18
3364 3490 18
3364 3490 18

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2129 Bbl 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 CORNER OPERATING COMPANY, INC 5975.00 105.00 365
1988 CORNER OPERATING COMPANY, INC 5334.00 109.00 365
1989 CORNER OPERATING COMPANY, INC 6303.00 65.00 365
1990 CORNER OPERATING COMPANY, INC 6213.00 36.00 365
1991 CORNER OPERATING COMPANY, INC 5802.00 49.00 365
1992 CORNER OPERATING COMPANY, INC 2059.00 0.00 365
1993 CORNER OPERATING COMPANY, INC 5006.00 0.00 365
1997 CORNER OPERATING COMPANY, INC 150.00 0.00 365
1998 BELVOIR ENERGY INC. 0.00 0.00 365
1999 BELVOIR ENERGY INC. 0.00 0.00 365
2000 BELVOIR ENERGY INC. 0.00 0.00 365
2001 BELVOIR ENERGY INC. 389.00 0.00 365
2002 BELVOIR ENERGY INC. 1066.00 84.00 365
2003 BELVOIR ENERGY INC. 1265.00 86.00 365
2004 BELVOIR ENERGY INC. 284.00 82.00 365
2005 BELVOIR ENERGY INC. 1077.00 80.00 365
2006 BELVOIR ENERGY INC. 280.00 75.00 365
2007 BELVOIR ENERGY INC. 857.00 72.00 365
2010 BELVOIR ENERGY INC. 826.00 34.00 365
2012 BELVOIR ENERGY INC. 0.00 0.00 366
2013 BELVOIR ENERGY INC. 521.00 26.00 0
2014 BELVOIR ENERGY INC. 786.00 37.00 0
2016 BELVOIR ENERGY INC. 322.00 0.00 0
2017 BELVOIR ENERGY INC. 0.00 0.00 0
2018 C & D OIL & GAS LLC 928.00 54.00 225

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 CORNER OPERATING COMPANY, INC Brine 324 365
1988 CORNER OPERATING COMPANY, INC Brine 139 365
1989 CORNER OPERATING COMPANY, INC Brine 433 365
1990 CORNER OPERATING COMPANY, INC Brine 60 365
1991 CORNER OPERATING COMPANY, INC Brine 70 365
1992 CORNER OPERATING COMPANY, INC Brine 0 365
1993 CORNER OPERATING COMPANY, INC Brine 0 365
1997 CORNER OPERATING COMPANY, INC Brine 24 365
1998 CORNER OPERATING COMPANY, INC Brine 0 365
1999 CORNER OPERATING COMPANY, INC Brine 18 365
2000 BELVOIR ENERGY INC. Brine 0 365
2001 BELVOIR ENERGY INC. Brine 0 365
2002 BELVOIR ENERGY INC. Brine 206 365
2003 BELVOIR ENERGY INC. Brine 173 365
2004 BELVOIR ENERGY INC. Brine 131 365
2005 BELVOIR ENERGY INC. Brine 171 365
2006 BELVOIR ENERGY INC. Brine 144 365
2007 BELVOIR ENERGY INC. Brine 152 365
2010 BELVOIR ENERGY INC. Brine 156 365
2012 BELVOIR ENERGY INC. Brine 0 366
2013 BELVOIR ENERGY INC. Brine 122 0
2014 BELVOIR ENERGY INC. Brine 140 0
2016 BELVOIR ENERGY INC. Brine 35 0
2017 BELVOIR ENERGY INC. Brine 0 0
2018 C & D OIL & GAS LLC Brine 40 225

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1077441900 2006-1-20 0:00: PW No Violations
-189079749 2019-3-25 0:00: PW No Violations
-895908030 2003-12-9 0:00: PW No Violations
0189079749 2019-03-25 Production Wells No Violations I conducted a compliance notice follow-up inspection on 03/25/2019. At the time of my inspection the well was in operation. The well is equipped with an electric pump jack unite. Production valve was open at well. The tank battery consisted of one 100-barrel production tank, one 210-barrel production, and mechanical separator. Proper identification was posted at the tank battery. The lease road was in stable condition. No identification was posted at well head. Plug was never fixed and is still seeping that was stated on previous reports. Tank battery is shared by well number 0879
0340036536 2018-12-12 Production Wells Violations Noted I conducted an inspection on this well. The well was equipped with a pumping unit and in production at the time of this inspection. The tank battery was comprised of one 210 BBL tank, one 100 BBL tank and a mechanical separator. Valves on the separator were open. The 210 BBL tank was seeping from a plug at the base of the tank. The diked tank battery was shared with well 2-0879. Legible identification was only located at the tank battery. The lease access was stable. I contacted Brent Dietrich from C & D Oil & Gas, LLC regarding the need for identification at the well location and cleanup and repair of the 210 BBL tank.

C&D Oil & Gas, LLC needs to: 1) Install identification at the well locations due to a shared battery 2) Empty and clean out the 210 BBL tank. Repair the tank at the leak location.

0895908030 2003-12-09 Production Wells No Violations Remedial work has been completed . Case# 03-008 has been resolved .
0961396696 2003-05-22 Preliminary Restoration Violations Noted Case#03-008 [ Walter K. Hennse Jr. ] Inspection showed route of flow line was very rough . There was a 2 steel pipe approx. 100 east of tank battery in flow line right-of-way sticking in air approx. 16 high . Well is in production . REMEDIAL WORK REQUIRED: Final grade flow line right-of-way from tank battery to well , cut old flow line below surface at least 30 and remove old flow line frow site . NOTE: Remedial date deadline is subject to change due to ground conditions due to heavy rain fall .
1077441900 2006-01-20 Production Wells No Violations no violations .
1538094151 2019-6-18 0:00: PW No Violations
1548694461 2019-01-28 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 340036536, regarding the repair of the 210 BBL seeping at the plug and installing identification at the well location. At the time of this inspection, neither the 210 BBL tank had been repaired or the identfication added at the well location. No other issues were observed at the well or tank battery location during this inspection.
1571841711 2019-10-22 0:00 PW No Violations
340036536 2018-12-12 0:00 PW No Violations
496114718 2020-1-6 0:00:0 PW No Violations
961396696 2003-5-22 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0340036536 US-OH-123511 2019-01-11 9-9-05(A)10 Failure to legibly identify well
0340036536 US-OH-123512 2019-01-11 9-9-05(A)8 Equipment pressure rated below operating pressure
0961396696 US-OH-131001 2003-06-01 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)

For data sources see[9]

References