X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-007-20262

Well Details

Well ID: 34-007-20262
Loading map...
Country: United States
State: Ohio
County: Ashtabula
Municipality: Morgan Township
Operator Name: C & D OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: DIXON
License Status: Producing
License Date: 1970-02-06
Spud Date: 1970-03-19
Spud Drilling Contractor:
Final Drill Date: 1971-03-31
Well Total Depth: 3485.00 ft
Configuration: Vertical
Latitude: 41.660000
Longitude: -80.810000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1970-02-06 3270 GROUP MAINTENANCE CORP GeoDate 2/6/70
Oil and Gas 1970-02-06 Issued Date 2/6/70 Expired Date Acres 0027540 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1970-03-19 GL=886.1, KB=890.1
Completion Report Received 1970-04-20 GL=886.1, KB=890.1
Completed 1971-03-31 GL=886.1, KB=890.1
Reached Total Depth 1971-03-31 GL=886.1, KB=890.1
Change of Owner 2004-07-13 Operator changed from 3270, GROUP MAINTENANCE CORP to 5952, BELVOIR ENERGY INC.
Change of Owner 2018-02-12 Operator changed from 5952, BELVOIR ENERGY INC. to 10067, C & D OIL & GAS LLC
Record Last Modified 2018-02-12 GL=886.1, KB=890.1

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3293 3340 0
3293 3340 0
3293 3340 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2909 Bbl 60000 48 HRS.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1988 GROUP MAINTENANCE CORP 1423.00 38.00 365
1989 GROUP MAINTENANCE CORP 1345.00 0.00 365
1990 GROUP MAINTENANCE CORP 4169.00 0.00 365
1991 GROUP MAINTENANCE CORP 1852.00 67.00 365
1992 GROUP MAINTENANCE CORP 0.00 0.00 365
1994 GROUP MAINTENANCE CORP 1371.00 0.00 360
1996 GROUP MAINTENANCE CORP 1062.00 0.00 360
1997 GROUP MAINTENANCE CORP 961.00 0.00 360
2006 GROUP MAINTENANCE CORP 1061.00 0.00 365
2007 BELVOIR ENERGY INC. 1377.00 0.00 365
2010 BELVOIR ENERGY INC. 1098.00 0.00 365
2012 BELVOIR ENERGY INC. 1174.00 0.00 366
2013 BELVOIR ENERGY INC. 891.00 0.00 365
2014 BELVOIR ENERGY INC. 987.00 0.00 365
2016 BELVOIR ENERGY INC. 248.00 0.00 365
2017 BELVOIR ENERGY INC. 0.00 0.00 365
2018 C & D OIL & GAS LLC 126.00 0.00 176

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1988 GROUP MAINTENANCE CORP Brine 78 365
1989 GROUP MAINTENANCE CORP Brine 53 365
1990 GROUP MAINTENANCE CORP Brine 0 365
1991 GROUP MAINTENANCE CORP Brine 92 365
1992 GROUP MAINTENANCE CORP Brine 0 365
1994 GROUP MAINTENANCE CORP Brine 548 360
1996 GROUP MAINTENANCE CORP Brine 0 360
1997 GROUP MAINTENANCE CORP Brine 92 360
2006 GROUP MAINTENANCE CORP Brine 0 365
2007 BELVOIR ENERGY INC. Brine 0 365
2010 BELVOIR ENERGY INC. Brine 0 365
2012 BELVOIR ENERGY INC. Brine 0 366
2013 BELVOIR ENERGY INC. Brine 0 365
2014 BELVOIR ENERGY INC. Brine 0 365
2016 BELVOIR ENERGY INC. Brine 0 365
2017 BELVOIR ENERGY INC. Brine 0 365
2018 C & D OIL & GAS LLC Brine 0 176

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1266926108 2018-10-29 0:00 PW No Violations
-1562476929 2005-10-21 0:00 PW No Violations
1147130804 2006-03-23 Production Wells No Violations Gas leak repaired , well in production . Case# 05-009 resolved .
1266926108 2018-10-29 Production Wells No Violations I conducted an inspection on this well. At the time of this inspection, the well was equipped with a plunger lift assembly and in production. The tank battery consisted of two 210 BBL tanks, one 100 BBL tank and a mechanical separator. There was a disconnected mechanical separator, adjacent to and outside of the diked battery. The diked tank battery had legible signage and was shared with wells 2-2302 and 2-2536. Lease access was stable. I contacted the company and spoke with Brent Dietrich regarding adding signage at the well location.
1562476929 2005-10-21 Production Wells Violations Noted Case# 05-009, Rodney . Inspection showed 4.5 casing leaking above 8 5/8 casing head , well is idle at this time .

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1562476929 US-OH-115248 2005-10-30 Well insufficiently equipped to prevent escape of oil and gas
1562476929 US-OH-115249 2005-10-30 Well shall be plugged

For data sources see[9]

References