Well Details

Well ID: 34-005-23072
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: GORTNER ROBERT & PAULINE
License Status: Active Injection
License Date: 1974-08-21
Spud Date: 1974-11-05
Spud Drilling Contractor:
Final Drill Date: 1974-11-12
Well Total Depth: 712.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.160000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Unknown 1802-01-01 Issued Date 8/7/74 Expired Date Acres Tool Type Proposed Formation Proposed Depth Proposed Drill Depth
Original Spud 1974-11-05 DRILLED BY KLAEGER AND BLODGETT
Completed 1974-11-12 DRILLED BY KLAEGER AND BLODGETT
Reached Total Depth 1974-11-12 DRILLED BY KLAEGER AND BLODGETT
Construction Permit Expires 1975-08-07 DRILLED BY KLAEGER AND BLODGETT
CO 1995-10-18 133 QUAKER STATE OIL REF CORP
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate
Annulus Pressure Monitoring Approved 1996-07-18 DRILLED BY KLAEGER AND BLODGETT
Last Compliance Report 1999-10-18 DRILLED BY KLAEGER AND BLODGETT
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-02-15 DRILLED BY KLAEGER AND BLODGETT

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-22 546 604 0
2000-05-22 604 673 0
604 673 0
546 604 0
546 604 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 191 Qts 0 190.5=VOLUME
NITR 0 190 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC 0.00 133.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1060102655 2012-5-31 0:00: ER No Violations
-1222262883 2018-4-23 0:00: ER No Violations
-126642649 2015-5-13 0:00: ER No Violations
-1268263053 2008-12-3 0:00: ER No Violations 0.50
-1389508060 2011-4-13 0:00: ER No Violations 0.50
-1454966613 2019-10-23 0:00 ER No Violations
-1501738487 2014-3-17 0:00: ER No Violations
-1578296743 2014-10-28 0:00 ER No Violations
-1646378764 2019-4-10 0:00: ER No Violations
-1703568070 2014-5-27 0:00: ER No Violations
-1726349739 2013-5-22 0:00: ER No Violations
-1873664358 2014-4-8 0:00:0 PW No Violations 0.50
-1925089435 2012-9-20 0:00: ER No Violations
-192673763 2018-10-12 0:00 ER No Violations
-2003054050 2004-4-22 0:00: ER No Violations
-2015503441 2007-10-12 0:00 ER No Violations 0.50
-2058875993 2018-1-4 0:00:0 ER No Violations
-420106183 2009-10-7 0:00: ER No Violations 0.50
-582050922 2006-1-25 0:00: ER No Violations 0.50
-58646195 2009-4-23 0:00: ER No Violations 1.00
-611327421 2008-2-20 0:00: ER No Violations 1.00
-612906072 2013-10-29 0:00 ER No Violations
-658334553 2016-1-6 0:00:0 ER No Violations
-857787205 2016-10-19 0:00 ER No Violations
-95459680 2013-3-4 0:00:0 ER No Violations
0058646195 2009-04-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0072879692 2005-04-28 Enhanced Recovery Project No Violations Injection pressure test.
0095459680 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0126642649 2015-05-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Injection tubing is heavily rusted and the PVC lining is visible. Well has equalized. Well was shut in. well needs to be pressure tested.
0183360630 2010-04-05 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0192673763 2018-10-12 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0235716932 2017-07-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The annulus valve broken due to winter freeze. Notified operator to replace parts.
0242255620 2007-03-30 Enhanced Recovery Project No Violations Annulus and injection pressure test.
0420106183 2009-10-07 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0534405781 2016-04-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0582050922 2006-01-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0599042842 2012-03-07 Enhanced Recovery Project No Violations Inspect Well.
0611327421 2008-02-20 Enhanced Recovery Project No Violations Annulus and injection pressure test.
0612906072 2013-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0658334553 2016-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0659955886 2015-09-23 Enhanced Recovery Project Violations Noted Inspect well for integrity and pressure. The well is shut in. The operator attempted to conduct a pressure test on the well. The well head tubing has rusted away. The annuls was on vacuum. The well was equalized during the 5/13/2015 Inspection.
0674690779 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0857787205 2016-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0858548148 2011-07-12 Enhanced Recovery Project No Violations inspect well.
0863156253 2016-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0916170477 2017-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The annulus test valve was replaced.
0918886374 2006-12-14 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0995675400 2018-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Inspect well for integrity and pressure.
1020744716 2011-11-17 Enhanced Recovery Project No Violations Inspect well.
1060102655 2012-05-31 Enhanced Recovery Project No Violations Inspect Well.
1145969137 2006-04-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1222262883 2018-04-23 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1268263053 2008-12-03 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1315228043 2017-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1389508060 2011-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1409732464 2015-10-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The Service rig has been set on the well.
1447880533 2015-11-02 Work Over Reconditioning No Violations The well is constructed with 2 3/8 inch tubing at a depth of 542 feet cemented to the surface. The well is open hole to the total depth of 712 feet. The packer failed and was replaced. The top most joint of PVC lined tubing was replaced with new pipe. Total of 20 joints of 25 foot sections of PVC lined one Inch tubing was run in the hole with a parmaco style packer set in compression. Approximately 300 gallon of fresh water were pumped through the tubing and circulated to the surface prior to setting the packer. The packer was set and the annulus was pressured up to 395 psi. The pressure was monitored for 15 minutes with 3.7% pressure loss. This is within the stated margin of 5% pressure loss. the well passes the Mechanical Integrity Test. The well head was reconstructed with new parts and put into production.
1501738487 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Need to pressure test annulus.
1502638327 2003-11-13 Enhanced Recovery Project No Violations
1517610291 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
1578296743 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1579634090 2020-1-17 0:00: ER No Violations
1589542225 2020-5-13 0:00: ER No Violations
1703568070 2014-05-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1726349739 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
183360630 2010-4-5 0:00:0 ER No Violations 0.50
1848374722 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1855340052 2020-7-15 0:00: ER No Violations
1873664358 2014-04-08 Production Wells No Violations ID posted. The well is equipped as an injection well on the enhanced recovery project.
1925089435 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1928752922 2017-04-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2003054050 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
2015503441 2007-10-12 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2058875993 2018-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2142479073 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Pressure tested annulus and held at 350 psi. The threads on the valve are bad and leak at gauge.
235716932 2017-7-18 0:00: ER No Violations
237325605 2019-7-23 0:00: ER No Violations
242255620 2007-3-30 0:00: ER No Violations
377141547 2019-1-14 0:00: ER No Violations
534405781 2016-4-19 0:00: ER No Violations
599042842 2012-3-7 0:00:0 ER No Violations
659955886 2015-9-23 0:00: ER No Violations
674690779 2014-7-17 0:00: ER No Violations
72879692 2005-4-28 0:00: ER No Violations 0.50
858548148 2011-7-12 0:00: ER No Violations
863156253 2016-7-6 0:00:0 ER No Violations
916170477 2017-10-19 0:00 ER No Violations
918886374 2006-12-14 0:00 ER No Violations 0.50
995675400 2018-7-6 0:00:0 ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0659955886 US-OH-127482 2015-12-15 Violation of injection tubing/fitting requirements