{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.73,"lon":-82.28,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Vermillion Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: BURKHOLDER BLAINE | |
License Status: Storage Well | |
License Date: 1968-06-27 | |
Spud Date: 1968-08-07 | |
Spud Drilling Contractor: | |
Final Drill Date: 1968-10-14 | |
Well Total Depth: 2803.00 ft | |
Configuration: Vertical | |
Latitude: 40.730000 | |
Longitude: -82.280000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1968-08-07 | |
Completed | 1968-10-14 | |
Reached Total Depth | 1968-10-14 | |
Record Last Modified | 2013-05-23 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2016-08-23 | H2O | 0 | 340 Bbl | 23589 | Reliance Well Service pumped the job for Columbia. The job was a nitrogen assisted hydro fracture. 250 gallons of hydrochloric acid were pumped ahead of the job. 65,589 cubic feet of nitrogen gas were pumped with the slurry. 20/40 sand was used in the job. The fluid portion of the slurry was cross linked fresh water gel with guar gelling agent. The Nitrogen truck was having mechanical problems during the job and delayed the start of pumping. The surface production annulus was open during |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-2004679935 | 2017-7-10 0:00: | SO | No Violations | 0.50 |
0167049710 | 2019-04-08 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #10796 on 04/08/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and a drip. Well identification is clearly displayed. No problems were noted at the time of the inspection. |
0307380665 | 2018-04-02 | Storage Well | No Violations | ID is posted and the location is maintained. The annulus is shut in. The well is equipped with a separator. |
0456763792 | 2014-01-13 | Storage Well | No Violations | ID posted, location maintained. Lucas 10796. |
0693332562 | 2014-09-17 | Storage Well | No Violations | ID posted. Vegetation around the well needs to be mowed. |
1088404791 | 2015-09-28 | Storage Well | No Violations | ID is posted and the location is maintained. |
1093357803 | 2020-7-16 0:00: | SO | No Violations | |
167049710 | 2019-4-8 0:00:0 | SO | No Violations | |
1725540420 | 2016-09-08 | Storage Well | No Violations | The well has been painted. The well is locked out. Workover equipment has been removed. |
2004679935 | 2017-07-10 | Storage Well | No Violations | ID is posted and the location is maintained. The annulus is shut in. The well is equipped with a separator. |
2102852108 | 2016-08-23 | Work Over Reconditioning | No Violations | The operator requested inspection to witness fracture stimulation of the storage well. The nitrogen pump truck had to be repaired on location prior to starting the job. The preheater turbine would not stay running. See the stimulation report for job details. |
307380665 | 2018-4-2 0:00:0 | SO | No Violations | |
456763792 | 2014-1-13 0:00: | SO | No Violations | 0.50 |
624471084 | 2020-8-17 0:00: | SO | No Violations | |
693332562 | 2014-9-17 0:00: | SO | No Violations | 0.50 |