X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-22624

Well Details

Well ID: 34-005-22624
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: SMALLEY ELLEN
License Status: Active Injection
License Date: 1983-06-10
Spud Date: 1983-08-05
Spud Drilling Contractor: WALTZ BROS DRLG
Final Drill Date: 1983-09-22
Well Total Depth: 695.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -82.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1967-09-21 Issued Date 9/21/67 Expired Date Acres 0080000 Tool Type RTAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1968-01-09 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
CO 1983-06-10 133 QUAKER STATE OIL REF CORP GeoDate 6/10/83
Enhanced Recovery 1983-06-10 Issued Date 6/10/83 Expired Date 12/7/83 Acres 0080000 Tool Type CT Proposed Formation BEREA Proposed Depth 00695 Proposed Drill Depth 00695
Completed 1983-09-22 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Reached Total Depth 1983-09-22 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
CO 1983-10-07 133 QUAKER STATE OIL REF CORP GeoDate 9/21/67
First Injection 1983-10-07 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Completion Report Received 1983-10-19 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Construction Permit Expires 1983-12-07 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 6/10/83
Annulus Pressure Monitoring Approved 1999-02-03 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Last Compliance Report 1999-12-15 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-02-15 LAST RECORD OF INJECTION IN 1998 CONVERT 6-11-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-23 613 667 0
2000-05-23 616 670 0
613 667 0
616 670 0
613 667 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 108 Qts 0
NITR 0 54 Qts 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1009310280 2016-11-2 0:00: ER No Violations
-1096785496 2019-7-10 0:00: ER No Violations
-1200273161 2014-5-6 0:00:0 ER No Violations
-1209770407 2019-1-10 0:00: ER No Violations
-1470950048 2011-10-17 0:00 ER No Violations
-1600636766 2015-9-10 0:00: WR No Violations
-1663106380 2018-10-10 0:00 ER No Violations
-1720930863 2012-11-27 0:00 ER No Violations
-1896148136 2015-11-24 0:00 WR No Violations
-190750458 2010-3-30 0:00: ER No Violations 0.50
-1965550883 2017-7-18 0:00: ER No Violations
-2042867641 2011-4-12 0:00: ER No Violations 0.50
-34574359 2014-3-17 0:00: ER No Violations
-350008696 2018-5-1 0:00:0 ER No Violations
-441446506 2012-2-27 0:00: ER No Violations
-444332237 2020-7-8 0:00:0 ER No Violations
-552071523 2005-4-27 0:00: ER No Violations 0.50
-700948314 2019-11-18 0:00 ER No Violations
-732105732 2016-4-19 0:00: ER No Violations
-919527522 2015-11-25 0:00 WR No Violations
-929514229 2019-4-11 0:00: ER No Violations
-96039442 2004-4-22 0:00: ER No Violations
-965122572 2015-11-17 0:00 WR No Violations
-999914706 2015-5-20 0:00: ER No Violations
0013689449 2013-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Pump shut down during inspection. Injector well head tubing in poor condition. Well was shut in during inspection.
0032239755 2012-05-30 Enhanced Recovery Project No Violations Inspect Well.
0034574359 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well shut in. The well head tubing is completely rusted away.
0096039442 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
0190750458 2010-03-30 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0266331644 2010-11-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0281568385 2007-04-03 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0297767009 2006-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test. Constructed with 2 tubing cemented at Berea cap and 1 tubing used for injection.
0333645949 2006-12-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0350008696 2018-05-01 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0364864536 2014-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The tubing has failed and the well is shut in.
0441446506 2012-02-27 Enhanced Recovery Project No Violations inspect well.
0535107925 2017-04-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0552071523 2005-04-27 Enhanced Recovery Project No Violations Injection well test.
0579471484 2018-08-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0610378602 2017-01-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0646164980 2018-05-02 Enhanced Recovery Project No Violations Inspect well with operator to preform monthly pressure test of the annulus on the well.
0732105732 2016-04-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0780872398 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0886106112 2008-11-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0919527522 2015-11-25 Work Over Reconditioning No Violations The operator pulled the tubing and the packer from the borehole. The well was shut in without the tubing and packer. The operator ran in the hole with a rebuilt Parmaco style packer and tubing. The packer was constructed with the PVC lined tubing and parts accumulated in the shop. The top most joint of tubing was replaced. Total of 22 joints of PVC lined tubing were installed in the well. An eight inch tail pipe was installed on the packer. The well was loaded with about 300 gallons of fresh water with corrosion inhibitor and circulated to the surface. The annulus was pressured up to 378 psi and the pressure monitored for a period of 20 minutes. The pressure stabilized from the 5 minute reading to the 20 minute reading with a pressure loss of 4 %. The Mechanical Integrity test is within the margin of error of 5 %. The well passed and the operator was notified that the well can be put into production.
0965122572 2015-11-17 Work Over Reconditioning No Violations The operator pulled the tubing and the packer from the borehole. The well was shut in without the tubing and packer. A replacement packer need to be prepared.
0999914706 2015-05-20 Enhanced Recovery Project Violations Noted Inspect well for integrity and pressure. Shut in. Mechanical integrity has failed.
1009310280 2016-11-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1018957873 2009-10-20 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1069132750 2016-07-08 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1101478813 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
1109405650 2011-07-12 Enhanced Recovery Project No Violations inspect well.
1110396287 2005-11-29 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1193748311 2007-10-30 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1200273161 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well was shut in. Well head tubing is badly rusted.
1290581189 2009-04-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1291581960 2020-1-23 0:00: ER No Violations
13689449 2013-12-4 0:00: ER No Violations
1456610305 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1458396818 2020-4-22 0:00: ER No Violations
1468268752 2017-11-15 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1470950048 2011-10-17 Enhanced Recovery Project No Violations Inspect well.
1472371530 2016-01-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Annulus fitting was frozen due to cold weather.
1527319777 2016-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Retest wellhead. Fittings have thawed out after freezing due to cold weather.
1600636766 2015-09-10 Work Over Reconditioning No Violations Inspect well location. Service rig has been mobilized to well location.
1627910918 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1663106380 2018-10-10 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1720930863 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1832966705 2008-02-20 Enhanced Recovery Project No Violations Annulus and injection pressure test.
1896148136 2015-11-24 Work Over Reconditioning No Violations The packer and tubing were previously removed from the well. The operator ran in the hole with a rebuilt Parmaco style packer and tubing. The packer was constructed with the PVC lined tubing parts accumulated in the shop. The top most joint of tubing was replaced. Total of 22 joints of PVC lined tubing were installed in the well. An eight inch tail pipe was installed on the packer.
1954764657 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1965550883 2017-07-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2015539308 2003-08-14 Enhanced Recovery Project No Violations
2042867641 2011-04-12 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2045093050 2018-01-08 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2127944663 2015-10-30 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The Service rig has been set on the well. The corn has not been harvested at time of inspection.
266331644 2010-11-26 0:00 ER No Violations 0.50
281568385 2007-4-3 0:00:0 ER No Violations 0.50
297767009 2006-4-13 0:00: ER No Violations 0.50
32239755 2012-5-30 0:00: ER No Violations
333645949 2006-12-13 0:00 ER No Violations 0.50
364864536 2014-10-29 0:00 ER No Violations
535107925 2017-4-27 0:00: ER No Violations
579471484 2018-8-13 0:00: ER No Violations
610378602 2017-1-9 0:00:0 ER No Violations
646164980 2018-5-2 0:00:0 ER No Violations
780872398 2013-5-22 0:00: ER No Violations
886106112 2008-11-26 0:00 ER No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0999914706 US-OH-131478 2015-12-15 Failure to conduct or pass mech. integrity test

For data sources see[5]

References