X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-22344

Well Details

Well ID: 34-005-22344
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: SMALLEY ELLEN (ERP #16)
License Status: Active Injection
License Date: 1983-06-10
Spud Date: 1983-08-15
Spud Drilling Contractor: HILLER DRLG
Final Drill Date: 1983-09-13
Well Total Depth: 675.00 ft
Configuration: Vertical
Latitude: 40.880000
Longitude: -82.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1965-02-08 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
Enhanced Recovery 1983-06-10 Issued Date 6/10/83 Expired Date 12/7/83 Acres 0081500 Tool Type CT Proposed Formation BEREA Proposed Depth 00675 Proposed Drill Depth 00675
Completed 1983-09-13 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
Reached Total Depth 1983-09-13 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
CO 1983-10-07 133 QUAKER STATE OIL REF CORP GeoDate 6/10/83
First Injection 1983-10-07 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
Completion Report Received 1983-10-19 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
Construction Permit Expires 1983-12-07 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 6/10/83
Annulus Pressure Monitoring Approved 1999-02-03 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
Last Compliance Report 1999-12-15 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-02-15 LAST RECORD OF INJECTION IN 1998. CONVERT 6-11-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-23 601 652 0
2000-05-23 605 650 0
605 650 0
601 652 0
601 652 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 38 Qts 0 FOR ERP
NITR 0 65 Qts 0 FOR PRODUCTION

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1118775194 2011-1-19 0:00: ER No Violations 1.00
-1129633442 2016-1-5 0:00:0 ER No Violations
-1154659536 2014-7-17 0:00: ER No Violations
-1162440834 2017-1-9 0:00:0 ER No Violations
-125768755 2011-4-12 0:00: ER No Violations 1.00
-1468507232 2013-5-22 0:00: ER No Violations
-1493230327 2015-3-31 0:00: ER No Violations
-1593216497 2010-3-30 0:00: ER No Violations 0.50
-1678262018 2012-2-27 0:00: ER No Violations
-1735087782 2012-9-20 0:00: ER No Violations
-1812185048 2018-10-10 0:00 ER No Violations
-1895068479 2017-7-18 0:00: ER No Violations
-1940304478 2016-7-8 0:00:0 ER No Violations
-1955136381 2013-12-4 0:00: ER No Violations
-2047093427 2010-11-26 0:00 ER No Violations 0.50
-487862548 2016-11-2 0:00: ER No Violations
-582778767 2018-4-27 0:00: ER No Violations
-741429670 2014-10-29 0:00 ER No Violations
-758344177 2019-4-11 0:00: ER No Violations
-79684485 2009-4-23 0:00: ER No Violations 0.50
-810655586 2008-2-20 0:00: ER No Violations 1.00
-881036359 2017-4-13 0:00: ER No Violations
-887189888 2005-4-27 0:00: ER No Violations 0.50
-910118954 2018-5-1 0:00:0 ER No Violations
-954934245 2015-10-30 0:00 ER No Violations
0001901063 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
0079684485 2009-04-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0125768755 2011-04-12 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0136811776 2015-05-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0293429851 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0323293583 2012-05-30 Enhanced Recovery Project No Violations Inspect Well. Threads on injector valve are bad.
0487862548 2016-11-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0495297653 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0582778767 2018-04-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0723258926 2008-12-02 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0741429670 2014-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0786456944 2018-08-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0810655586 2008-02-20 Enhanced Recovery Project Violations Noted Annulus and injection pressure test. Annular side is 0 psi. Pump up to 200 psi and test for 15 minutes.
0820569584 2007-10-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0881036359 2017-04-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0887189888 2005-04-27 Enhanced Recovery Project No Violations Injection well test.
0910118954 2018-05-01 Enhanced Recovery Project No Violations Inspect well with operator to preform monthly pressure test of the annulus on the well.
0911471498 2005-11-29 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0936634929 2015-08-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0946144386 2007-04-03 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0954934245 2015-10-30 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1061291579 2003-08-14 Enhanced Recovery Project No Violations PRESSURE EQUALIZATION ON ANNULUS AND TUBING, REQUESTED MINI-TEST TO BE PERFORM
1096144866 2008-02-21 Enhanced Recovery Project No Violations Retest packer. Pressured uo annulus to 320 psi and after 15 minutes 0 psi decline. NOV in compliance.
1101472472 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
1118775194 2011-01-19 Enhanced Recovery Project No Violations Injection and annulus pressure test. Replaced packer. Pumped up annulus to 290 psi and 0 psi decline in 15 minutes. Topped off annulus between 2 3/8 tubing and surface casing with 30 sacks of Class A cement. 120 - 0. 1-13-2011.
1127154813 2019-1-10 0:00: ER No Violations
1129633442 2016-01-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1154659536 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1162440834 2017-01-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1281915617 2020-4-21 0:00: ER No Violations
1290081520 2016-04-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
136811776 2015-5-20 0:00: ER No Violations
1466604513 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1468507232 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1473375916 2018-01-08 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1493230327 2015-03-31 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1540045117 2011-07-12 Enhanced Recovery Project No Violations inspect well.
1563453653 2019-7-2 0:00:0 ER No Violations
1593216497 2010-03-30 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1594073220 2017-11-14 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1647328236 2006-04-13 Enhanced Recovery Project No Violations Injectin and annulus pressure test. Constructed with 2 tubing cemented at Berea cap with 1 tubing used for injection.
1678262018 2012-02-27 Enhanced Recovery Project No Violations inspect well.
1735087782 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1812185048 2018-10-10 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1881750200 2006-12-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1895068479 2017-07-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1901063 2004-4-22 0:00: ER No Violations
1933399299 2011-10-17 Enhanced Recovery Project No Violations Inspect well.
1934962179 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1940304478 2016-07-08 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1955136381 2013-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Pump shut down during inspection.
2047093427 2010-11-26 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equal at 320 PSI. Reset packer and test.
2061164190 2009-10-20 Enhanced Recovery Project No Violations Injection and annulus pressure test.
236035322 2019-11-18 0:00 ER No Violations
293429851 2013-3-4 0:00:0 ER No Violations
323293583 2012-5-30 0:00: ER No Violations
418090556 2020-1-23 0:00: ER No Violations
495297653 2012-11-27 0:00 ER No Violations
716658103 2020-7-8 0:00:0 ER No Violations
723258926 2008-12-2 0:00: ER No Violations 1.00
786456944 2018-8-13 0:00: ER No Violations
820569584 2007-10-26 0:00 ER No Violations 0.50
911471498 2005-11-29 0:00 ER No Violations 0.50
936634929 2015-8-31 0:00: ER No Violations
946144386 2007-4-3 0:00:0 ER No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0810655586 US-OH-129227 2008-02-20 Failure to conduct or pass mech. integrity test
2047093427 US-OH-120849 2010-11-26 Failure to conduct or pass mech. integrity test

For data sources see[5]

References