X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-21791

Well Details

Well ID: 34-005-21791
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: GLADYS C. MANN
License Status: Final Restoration
License Date: 2013-05-29
Spud Date: 1976-08-27
Spud Drilling Contractor: SHORTS DRLG
Final Drill Date: 1976-09-02
Well Total Depth: 652.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1975-04-10 133 QUAKER STATE OIL REF CORP GeoDate 4/10/75
Enhanced Recovery 1975-04-10 Issued Date 4/10/75 Expired Date Acres 0001700 Tool Type CRAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Completed 1976-08-27 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
Original Spud 1976-08-27 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
Reached Total Depth 1976-09-02 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 4/10/75
Annulus Pressure Monitoring Approved 1998-11-23 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
Last Compliance Report 1999-10-05 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
APP 2013-05-29 Proposed Formations:BEREA, Issued Date:5/29/2013, Expired Date:5/29/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:EOR, Proposed Well Class:
Plugged/Abandoned 2013-06-20 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
Construction Permit Expires 2015-05-29 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE
Record Last Modified 2017-02-15 SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-19 570 614 0
570 614 0
570 614 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 40 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC 0.00 13.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1082935222 2006-12-29 0:00 ER No Violations 1.00
-111963044 2007-3-30 0:00: ER No Violations
-1464663205 2013-5-8 0:00:0 ER No Violations
-1542833910 2008-12-11 0:00 ER No Violations 0.50
-1565115727 2007-10-22 0:00 ER No Violations 2.00
-1565488129 2006-12-15 0:00 ER No Violations
-1609952911 2012-2-27 0:00: ER No Violations
-1722416447 2009-4-25 0:00: ER No Violations 0.50
-1958963302 2007-4-3 0:00:0 ER No Violations 1.00
-208962727 2006-3-15 0:00: ER No Violations 1.00
-279559499 2010-11-27 0:00 ER No Violations 0.50
-43150819 2008-3-27 0:00: ER No Violations 0.50
-473608655 2011-7-12 0:00: ER No Violations
-502459913 2003-8-7 0:00:0 ER No Violations
-503156724 2011-10-17 0:00 ER No Violations
-511764643 2012-9-11 0:00: ER No Violations
-625117970 2004-11-18 0:00 ER No Violations
-735082993 2011-4-13 0:00: ER No Violations 0.50
0040325828 2012-12-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0043150819 2008-03-27 Enhanced Recovery Project No Violations Annulus and injection pressure test.
0111057061 2010-04-06 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0111963044 2007-03-30 Enhanced Recovery Project Violations Noted Injection and annulaus pressure test. Pressures are equalized at 350 psi.
0208962727 2006-03-15 Enhanced Recovery Project Violations Noted Re-test annulus and tubing pressures. Nov in compliance. Snow, 29 degrees
0279559499 2010-11-27 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0473608655 2011-07-12 Enhanced Recovery Project No Violations inspect well
0502459913 2003-08-07 Enhanced Recovery Project No Violations UNABLE TO GAUGE INJECTION PRESSURE, NEED TO REPLACE WITH VALVE TAP FOR 1/4 OR 1/2 GAUGE
0503156724 2011-10-17 Enhanced Recovery Project No Violations Inspect well.
0510006879 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0511764643 2012-09-11 Enhanced Recovery Project No Violations Inspect Well. Site ok.
0583280891 2005-12-01 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures have equalized at 350 psi.
0625117970 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
0735082993 2011-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0751620049 2006-04-24 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0763086463 2013-04-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Conduct fifteen minute pressure test on well. Test failed. Well shut in.
0774942903 2013-10-17 Final Restoration No Violations All equipment has been removed from the site. The location is finish graded and vegetated. Casing has been cut off. The final restoration is approved.
0923400769 2009-10-07 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1082935222 2006-12-29 Enhanced Recovery Project No Violations NOV followup. Ran Mini test on annulus and pressure held at 410psi for 15 minutes. Injection pressure is at 350 psi.
111057061 2010-4-6 0:00:0 ER No Violations 0.50
1116355295 2005-05-17 Enhanced Recovery Project No Violations Injection well test. GPS location and update to RBDMS.
1192038614 2007-10-10 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equalized at 330 psi. Suspended well operation at this time.
1350741638 2012-06-04 Enhanced Recovery Project No Violations Inspect Well. Annulus valve was replaced. Box needs repair.
1371742425 2013-06-20 Plug / Plug Back No Violations Request from operator to witness well plugging. The well was plugged with 9 sack grout.
1376581904 2013-08-15 Final Restoration No Violations The site needs to be graded and a pipe rack with 1 inch tubing removed to approve final restoration. Randy at Deep Resources was advised. He stated he would call when work is complete.
1464663205 2013-05-08 Enhanced Recovery Project No Violations Operator pickled and cleaned casing with acid. Run tubing and packer with new rubbers and cage. Pressure test of well did not pass. Significant loss of pressure when tested. Five times a joint of pipe was pulled up, packer set, loaded with water and pressure tested. Each test failed. Tool pusher reported the packer would set down at a depth of 268 feet below grade. Pulled packer up and set at 257 ft. above obstruction. Pressure tested ok at 257. The following day the packer was set and tested at 293 ft., below obstruction. Pressure test failed. Hole in casing about 268 feet. Reviewed old records the original well was drilled 8 to 10 inches from current hole. Due to casing being pushed out of bore hole by shooting with nitroglycerin. Well will be plugged.
1542833910 2008-12-11 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1565115727 2007-10-22 Enhanced Recovery Project No Violations Reset packer and tested but pressure equilized. Recommend pulling packer out and inspect. Shut well in until it will test.
1565488129 2006-12-15 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equalized at 350 psi.
1609952911 2012-02-27 Enhanced Recovery Project No Violations Inspect well. Valve on Annulus is broken.
1722416447 2009-04-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1850524506 2007-10-30 Enhanced Recovery Project No Violations Mechanical integrity test. Pulled 1 tubing and packer. Replaced packer and circulated inhibitor thru annulus and pressure tested packer and tubing at 350 psi. Drop of 10 psi in 15 minutes. NOV in compliance. Sun, 55 degrees.
1948417058 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test. Could not test tubing pressure due to size of gauge threads. Advised Len Rex to install reducer and test. Report to Tom Tomastik in 30 days.
1958963302 2007-04-03 Enhanced Recovery Project No Violations NOV in compliance. Blew down annulus and pressured up to 320 psi. Pressure held at 320 psi for 15 minutes. 0% decline. Injection pressure is 290 psi. Advised Matt Miller of injection pressure decline. Run mini test April 30, 2007 and report to inspector.
2018932901 2013-05-02 Enhanced Recovery Project No Violations Run packer and tubing into well, 21 joints at 25 feet each with a Butler Larkin 6 inch compression packer with new rubbers. Each individual joint of tubing was pressure tested for leaks. The packer was originally set at 525 feet. Formation gas was leaking past packer and the test was not successful. Operator will install tie downs to set and hold packer.
40325828 2012-12-4 0:00: ER No Violations
510006879 2013-3-4 0:00:0 ER No Violations
583280891 2005-12-1 0:00: ER No Violations 0.50
751620049 2006-4-24 0:00: ER No Violations 0.50
763086463 2013-4-4 0:00:0 ER No Violations
774942903 2013-10-17 0:00 FR No Violations 0.50
923400769 2009-10-7 0:00: ER No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0111963044 US-OH-103040 2007-03-30 Failure to conduct or pass mech. integrity test
0208962727 US-OH-121336 2005-12-07 Mechanical failure/contamination
0583280891 US-OH-126548 2005-12-07 Mechanical failure/contamination
1192038614 US-OH-105072 2007-10-10 Failure to conduct or pass mech. integrity test
1565488129 US-OH-115294 2006-12-15 Failure to conduct or pass mech. integrity test

For data sources see[9]

References