X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-20929

Well Details

Well ID: 34-005-20929
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Hanover Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: STEINMAN HUNTER A
License Status: Storage Well
License Date:
Spud Date: 1953-05-11
Spud Drilling Contractor:
Final Drill Date: 1953-06-18
Well Total Depth: 2832.00 ft
Configuration: Vertical
Latitude: 40.600000
Longitude: -82.330000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1953-05-11 GL=1273.6
Completed 1953-06-18 GL=1273.6
Reached Total Depth 1953-06-18 GL=1273.6
Record Last Modified 2013-05-23 GL=1273.6

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2017-08-17 FOAM 0 327 Bbl 20746 Reliance Well Service The job was only partially witnessed. Mechanical issues with the lubrication system on the pump truck delayed the job and the inspector had to leave for a plug job at another location. 500 gallons of 15% Hydrochloric acid were pumped and displaced before the pump truck shut down. The acidization was witnessed. The remainder of the stimulation was not witnessed. Rick Conley of Columbia Gas was on site for the job. Cross linked guar fresh water gel was used for the fluid. API 20/40 sand was
0 0 0

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2002 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2003 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2004 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2005 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2006 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2002 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2003 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2004 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2005 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2006 COLUMBIA GAS TRANSMISSION LLC Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1459833861 2014-12-5 0:00: SO No Violations 0.50
-2052062369 2019-4-2 0:00:0 SO No Violations
1392143223 2014-02-11 Storage Well No Violations ID posted, location maintained. 30 Bbl tank connected to the drip. 5 Bbl tank on the house meter.
1425444848 2017-08-17 Storage Well No Violations The operator requested inspection to witness fracture stimulation of the well. The job was scheduled for 9 AM. On arrival, Reliance Well Services was mixing gel for the job. The job started at 10:30 and acid was pumped and displaced. The pump truck developed a mechanical issue with the lubrication system and shut down. The remainder of the job was not witnessed due to plugging in Sullivan Township with another operator. The issue with the truck was corrected and the job was completed.
1429105256 2020-5-13 0:00: SO No Violations
1447440595 2015-11-13 Storage Well No Violations ID is posted and the location is maintained. There is a 30 barrel tank at the well. The annulus is open.
1459833861 2014-12-05 Storage Well No Violations ID posted, location maintained. There is an empty 25Bbl tank connected to the well.
1507734901 2017-10-11 Storage Well No Violations ID is posted and the location is maintained. The well remains shut in and unhooked from the pipeline following the workover stimulation. There is a 25 barrel tank connected to the separator.
1897467914 2016-04-29 Storage Well No Violations ID is posted and the location is maintained. The annulus is open. There is a 25 barrel tank connected to the separator. The tank is empty.
1924226377 2018-12-13 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #9214 on 12/13/2018. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-50 bbl steel tank. Well identification is clearly displayed. No problems were noted at the time of the inspection.
2052062369 2019-04-02 Storage Well No Violations Inspect well, identification is posted. A drip is located in line. A 30 barrel steel drip tank is located at the wellhead. A meter with a 210 gallon poly tote is located adjacent to the well.

For data sources see[8]

References