Well ID: 34-005-20879 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.69,"lon":-82.3,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Green Township | |
Operator Name: COLUMBIA GAS TRANSMISSION LLC | |
Well Pad ID: | |
Farm/Lease Name: MOWERY CHAS C | |
License Status: Storage Well | |
License Date: 1953-01-31 | |
Spud Date: 1953-04-07 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: | |
Well Total Depth: 2788.00 ft | |
Configuration: Vertical | |
Latitude: 40.690000 | |
Longitude: -82.300000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Construction Permit Expires | 1953-02-26 | LUCAS STORAGE FIELD |
Inspector Comments Cement Job | 1953-04-07 | LUCAS STORAGE FIELD - Gas and cement began to flow from 5.5" and 8.625" annular space after plug was down. After gas dissapates Columbia will run a small string down annular space and top off cement to surface.Cement Ticket Notes Inspector Reporting MORAVY HAROLD |
Original Spud | 1953-04-07 | LUCAS STORAGE FIELD |
Record Last Modified | 2017-02-15 | LUCAS STORAGE FIELD |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2004-08-19 | 795 | 0 | |
795 | 0 | ||
795 | 0 |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-100123963 | 2014-10-7 0:00: | SO | No Violations | 0.50 |
-1276313132 | 2019-4-23 0:00: | SO | No Violations | |
-1362567671 | 2017-8-3 0:00:0 | SO | No Violations | |
-1547882972 | 2020-1-27 0:00: | SO | No Violations | |
-1611449556 | 2016-9-27 0:00: | SO | No Violations | 0.50 |
-2088540788 | 2015-10-21 0:00 | SO | No Violations | 0.50 |
0100123963 | 2014-10-07 | Storage Well | No Violations | ID posted, location maintained. |
0143909562 | 2013-12-10 | Storage Well | No Violations | ID posted, location maintained. |
1276313132 | 2019-04-23 | Storage Well | No Violations | Performed annual inspection for Columbia Gas Storage Well #9178 on 04/23/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and 2-meters with 4-regulators. Well identification is clearly displayed. No problems were noted at the time of the inspection. |
1362567671 | 2017-08-03 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. There is no separator at the well. There are house gas taps at the pipeline tie in. |
143909562 | 2013-12-10 0:00 | SO | No Violations | 0.50 |
1539632687 | 2018-10-15 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a house gas connection at the pipeline tie in. |
1611449556 | 2016-09-27 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in. |
1621569347 | 2019-03-06 | Storage Well | No Violations | Inspect well, identification is posted. |
2088540788 | 2015-10-21 | Storage Well | No Violations | ID is posted and the location is maintained. The well is shut in at the gate valve and the annulus valves are closed and plugged. |