34-005-20878

Well Details

Well ID: 34-005-20878
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Vermillion Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: KRINO GEO P
License Status: Storage Well
License Date: 1953-02-12
Spud Date: 1953-02-12
Spud Drilling Contractor:
Final Drill Date: 1953-03-17
Well Total Depth: 2717.00 ft
Configuration: Vertical
Latitude: 40.750000
Longitude: -82.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1953-03-17
Original Spud 1953-03-17
Reached Total Depth 1953-03-17
Record Last Modified 2017-02-15

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
Not Treated 0 4431 Gal 1200 KEROSENE, R.P. 96 HRS.
OIL 0 4431 Gal 1200

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1082046312 2015-10-7 0:00: SO No Violations 0.50
-1181844693 2020-1-23 0:00: SO No Violations
-122293011 2016-10-5 0:00: SO No Violations 0.50
-2067614970 2013-12-18 0:00 SO No Violations 0.50
-701788014 2018-10-1 0:00: SO No Violations
-95224814 2020-1-23 0:00: SO No Violations
0122293011 2016-10-05 Storage Well No Violations ID is posted. The farmer has planted crops through the lease road eliminating it. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator.
0472826629 2014-10-15 Storage Well No Violations The wrong API is on the ID sign. The well tender was contacted to fix ID. The well and location are maintained. The side gate valve is closed.
0701788014 2018-10-01 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator and house gas connection at the pipeline tie in.
1082046312 2015-10-07 Storage Well No Violations ID is posted. Vegetation around the well needs to be mowed. The well is shut in at the gate valve; the annulus is open.
1300511519 2019-04-08 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #9182 on 04/08/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, a drip, and 1-meter with 2-regulators. Well identification is clearly displayed. The well is located ~140 from its RBDMS location. A map showing the location discrepancy, as well as a request for the location to be updated in RBDMS was sent to Aaron Lantz (DOGRM Columbus). No other problems were noted at the time of the inspection.
2009802443 2017-07-11 Storage Well No Violations ID is posted and the location is maintained. The well is shut in at the gate valve; the annulus is open. The well is equipped with a separator and house gas tap at the pipeline tie in.
2067614970 2013-12-18 Storage Well No Violations The API needs to be placed on the ID tag. The well is shut in, location maintained.
472826629 2014-10-15 0:00 SO No Violations 0.50

For data sources see[4]

References