Well Details

Well ID: 0404081813002
Loading map...
Location: 00/13-18-040-08W4/2
Location Alias: 00/13-18-40-08 W4M
Location Alias 2: 00/13-18-040-08 W4/02
Country: Canada
Province: Alberta
Township: 040
Meridian: 4
Range: 08
Section: 18
County/Municipality: Municipal District of Provost No. 52
Well Name: SLE PROVOST 13-18-40-8
Operator Name: SanLing Energy Ltd.
License Number: 0353482
License Date: 2006-03-06
License Status: Abandoned
Spud Date: 2006-03-11
Final Drill Date: 2006-03-13
Well Total Depth: 986.00 m
Surface Hole Latitude: 52.445530
Surface Hole Longitude: -111.149585

For data sources see[1][2]

Well History

Date Event
2006-03-06 Obtained License
2006-03-12 Direction Drilling Operation Performed - Deviate
2006-03-12 Surface Casing Operation Performed
2006-03-13 Finished Drilling
2006-03-13 Well Log Performed
2006-03-13 Well Mode changed to Drilled and Cased
2006-03-14 Production Casing Operation Performed
2006-03-14 Rig Released
2006-03-29 Perforation Treatment Performed - Jet Perforation
2006-03-29 Well Log Performed
2006-10-08 Perforation Treatment Performed - Bridge Plug Capped W/Cement
2006-10-08 Perforation Treatment Performed - Jet Perforation
2006-10-08 Plug Back Performed
2006-10-08 Well Log Performed
2006-10-13 Well Began Production
2006-10-13 Well Fluid changed to Gas
2006-10-13 Well Mode changed to Flowing
2007-01-17 Perforation Treatment Performed - Jet Perforation
2007-01-17 Well Log Performed
2007-01-26 Well Fluid changed to Gas
2007-01-26 Well Mode changed to Flowing
2012-11-01 Well Fluid changed to Gas
2012-11-01 Well Mode changed to Suspended
2018-03-02 Perforation Treatment Performed - Bridge Plug Capped W/Cement
2018-03-02 Plug Back Performed
2018-03-02 Well Fluid changed to Gas
2018-03-02 Well Mode changed to Abandoned Zone
2018-03-15 Well Abandoned

For data sources see[3]

Directional Drilling

Start Date Depth (m) Reason
2006-03-12 432.00 Deviate (5 - 79 degrees)

For data sources see[4]

Perforation Treatments

Perforation Date Perforation Type Interval Top (m) Interval Base (m) Number of Shots
2006-03-29 Perforation 917.00 918.50 17
2006-10-08 Packing Device Capped w/Cement 905.80 913.80 0
2006-10-08 Perforation 867.00 868.00 17
2007-01-17 Perforation 822.00 826.00 17
2018-03-02 Packing Device Capped w/Cement 851.10 861.10 0
2018-03-02 Packing Device Capped w/Cement 807.00 817.00 0

For data sources see[5]


Production Data

Period Total Production Hours Gas Quantity (m3) Oil Quantity (m3) Water Quantity (m3)
2006 2208 0.0 0.0 0.0
2007 8615 0.0 0.0 0.0
2008 7564 0.0 0.0 0.0
2009 5385 0.0 0.0 0.0
2010 2598 0.0 0.0 0.0
2011 6583 0.0 0.0 0.0

For data sources see[6]

Occurences

Occurence Date Occurence Type Occurence Depth (m) Occurence Control Depth (m)
2018-03-04 No Incident Encountered 0.00 0.00

For data sources see[7]