If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
m |
m |
||
Line 3: | Line 3: | ||
{| class="wikitable welldetails" width="95%" | {| class="wikitable welldetails" width="95%" | ||
| Well ID: 37-129-28463 | | Well ID: 37-129-28463 | ||
− | | style="height=100%; align=center" rowspan=" | + | | style="height=100%; align=center" rowspan="17" | {{#display_map: 40.176667, -79.7020 | width=100% | height=100% }} |
|- | |- | ||
| Country: United States | | Country: United States | ||
Line 19: | Line 19: | ||
| Farm/Lease Name: HEPLER UNIT 3H | | Farm/Lease Name: HEPLER UNIT 3H | ||
|- | |- | ||
− | | License Status: | + | | License Status: |
|- | |- | ||
− | | Spud Date: | + | | Spud Date: |
|- | |- | ||
| Permit Date: 2010-11-02 | | Permit Date: 2010-11-02 | ||
+ | |- | ||
+ | | Well Type: GAS | ||
|- | |- | ||
| Unconventional Well: Y | | Unconventional Well: Y | ||
|- | |- | ||
| Configuration: Horizontal Well | | Configuration: Horizontal Well | ||
+ | |- | ||
+ | | Conservation: Yes | ||
|- | |- | ||
| Latitude: 40.176667 | | Latitude: 40.176667 | ||
Line 49: | Line 53: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-05-21 }}</ref> | | accessdate = 2019-05-21 }}</ref> | ||
+ | == Well History == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Date | ||
+ | !scope="col" | Event | ||
+ | |- | ||
+ | | 2010-11-02 | ||
+ | | New Permit Application | ||
+ | |- | ||
+ | | 2010-11-18 | ||
+ | | Performed Spud Operation | ||
+ | |- | ||
+ | | 2011-05-24 | ||
+ | | Drilling Completion | ||
+ | |- | ||
+ | | 2011-07-07 | ||
+ | | Perforation | ||
+ | |- | ||
+ | | 2013-10-15 | ||
+ | | DEVIATED | ||
+ | |- | ||
+ | |} | ||
+ | For data sources see<ref>{{cite web | ||
+ | | title = Compiled from multiple data sources - see Pennsylvania Oil and Gas Data Sources | ||
+ | | date = 2020-02-27 | ||
+ | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
+ | | accessdate = 2020-02-27 }}</ref> | ||
== Fracking Activities == | == Fracking Activities == | ||
==== Fracking Jobs ==== | ==== Fracking Jobs ==== | ||
Line 62: | Line 92: | ||
| 2011-07-12 | | 2011-07-12 | ||
| 2011-07-12 | | 2011-07-12 | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,704 |
− | | style="text-align: right;" | 4,367,255 | + | | style="text-align: right;" | 4,367,255 |
| style="text-align: right;" | | | style="text-align: right;" | | ||
|- | |- | ||
Line 188: | Line 218: | ||
| url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources | ||
| accessdate = 2019-06-19 }}</ref> | | accessdate = 2019-06-19 }}</ref> | ||
+ | <!--== Stimulation Data == | ||
+ | {| class="wikitable sortable" width="95%" | ||
+ | !scope="col" | Stimulation Date | ||
+ | !scope="col" | Phase Number | ||
+ | !scope="col" | Chemical Agent | ||
+ | !scope="col" | Volume (gal) | ||
+ | !scope="col" | Treating Pressure (psi) | ||
+ | !scope="col" | Breakdown Pressure (psi) | ||
+ | |- | ||
+ | |}--> | ||
+ | |||
== Production Data == | == Production Data == | ||
{| class="wikitable sortable" width="95%" | {| class="wikitable sortable" width="95%" | ||
Line 282: | Line 323: | ||
| 2019 | | 2019 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | style="text-align: right;" | | + | | style="text-align: right;" | 157,424.00 |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 365 |
| style="text-align: right;" | 0.00 | | style="text-align: right;" | 0.00 | ||
| style="text-align: right;" | 0 | | style="text-align: right;" | 0 | ||
Line 307: | Line 348: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 110.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | WMGR123SW001 |
|- | |- | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | + | | style="text-align: right;" | 360.00 Bbl | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | | style="text-align: right;" | | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
| WMGR123SW001 | | WMGR123SW001 | ||
Line 335: | Line 362: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 180.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | 301353 |
|- | |- | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Drilling Fluid Waste | + | | Drilling Fluid Waste |
| style="text-align: right;" | 3,379.00 Bbl | | style="text-align: right;" | 3,379.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 349: | Line 376: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Drilling Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 930.00 Bbl |
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | 301353 |
|- | |- | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracing Fluid Waste | + | | Fracing Fluid Waste |
| style="text-align: right;" | 21,294.30 Bbl | | style="text-align: right;" | 21,294.30 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 363: | Line 390: | ||
| 2011 | | 2011 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 325.00 Bbl |
+ | | IDENTIFY METHOD IN COMMENTS | ||
+ | | 34-167-29359 | ||
+ | |- | ||
+ | | 2011 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Drilling Fluid Waste | ||
+ | | style="text-align: right;" | 500.00 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
− | | | + | | PA0095273 |
|- | |- | ||
− | | | + | | 2011 |
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 55.00 Bbl |
− | | | + | | CENTRALIZED TREATMENT PLANT FOR RECYCLE |
− | | | + | | PA0091472 |
|- | |- | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 6,194.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
Line 384: | Line 418: | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | | + | | Fracing Fluid Waste |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 630.00 Bbl |
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
Line 391: | Line 425: | ||
| 2012 | | 2012 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Fracturing Fluid Waste | + | | Fracturing Fluid Waste |
| style="text-align: right;" | 0.30 Tons | | style="text-align: right;" | 0.30 Tons | ||
| LANDFILL | | LANDFILL | ||
| 100419 | | 100419 | ||
|- | |- | ||
− | | | + | | 2012 |
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 449.00 Bbl |
− | | | + | | INJECTION DISPOSAL WELL |
− | | | + | | 34-121-23995 |
|- | |- | ||
| 2013 | | 2013 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 2,703.00 Bbl | | style="text-align: right;" | 2,703.00 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
| | | | ||
|- | |- | ||
− | | | + | | 2013 |
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 44.00 Bbl |
− | | | + | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) |
− | | | + | | WMGR123SW001 |
|- | |- | ||
| 2014 | | 2014 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 595.00 Bbl | | style="text-align: right;" | 595.00 Bbl | ||
| RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | ||
| WMGR123SW001 | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2014 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 405.67 Bbl | ||
+ | | REUSE OTHER THAN ROAD SPREADING | ||
+ | | | ||
|- | |- | ||
| 2015 | | 2015 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 618.33 Bbl | | style="text-align: right;" | 618.33 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 433: | Line 474: | ||
| 2016 | | 2016 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 332.02 Bbl | | style="text-align: right;" | 332.02 Bbl | ||
| CENTRALIZED TREATMENT PLANT FOR RECYCLE | | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ||
Line 440: | Line 481: | ||
| 2016 | | 2016 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 347.34 Bbl | | style="text-align: right;" | 347.34 Bbl | ||
| REUSE OTHER THAN ROAD SPREADING | | REUSE OTHER THAN ROAD SPREADING | ||
Line 447: | Line 488: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Soil Contaminated by Oil | + | | Soil Contaminated by Oil |
| style="text-align: right;" | 0.08 Tons | | style="text-align: right;" | 0.08 Tons | ||
| RESIDUAL WASTE TRANSFER FACILITY | | RESIDUAL WASTE TRANSFER FACILITY | ||
Line 454: | Line 495: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
+ | | style="text-align: right;" | 1,616.67 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW001 | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Produced Fluid | ||
+ | | style="text-align: right;" | 111.67 Bbl | ||
+ | | RESIDUAL WASTE PROCESSING FACILITY | ||
+ | | WMGR123SW019 | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Soil Contaminated by Oil & Gas Related Spills | ||
+ | | style="text-align: right;" | 0.08 Tons | ||
+ | | RESIDUAL WASTE TRANSFER FACILITY | ||
+ | | 101532 | ||
+ | |- | ||
+ | | 2017 | ||
+ | | [[CHEVRON APPALACHIA LLC]] | ||
+ | | Produced Fluid | ||
| style="text-align: right;" | 74.00 Bbl | | style="text-align: right;" | 74.00 Bbl | ||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
Line 461: | Line 523: | ||
| 2017 | | 2017 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 221.67 Bbl | | style="text-align: right;" | 221.67 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
|- | |- | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 216.66 Bbl | | style="text-align: right;" | 216.66 Bbl | ||
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
Line 489: | Line 537: | ||
| 2018 | | 2018 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
| style="text-align: right;" | 331.00 Bbl | | style="text-align: right;" | 331.00 Bbl | ||
| REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | ||
Line 496: | Line 544: | ||
| 2019 | | 2019 | ||
| [[CHEVRON APPALACHIA LLC]] | | [[CHEVRON APPALACHIA LLC]] | ||
− | | Produced Fluid | + | | Produced Fluid |
− | | style="text-align: right;" | | + | | style="text-align: right;" | 396.67 Bbl |
| REUSE (AT WELL PAD) | | REUSE (AT WELL PAD) | ||
| | | |
Well ID: 37-129-28463 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.176667,"lon":-79.702,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Westmoreland | |
Municipality: South Huntingdon Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148513 | |
Farm/Lease Name: HEPLER UNIT 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-11-02 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.176667 | |
Longitude: -79.7020 |
Date | Event |
---|---|
2010-11-02 | New Permit Application |
2010-11-18 | Performed Spud Operation |
2011-05-24 | Drilling Completion |
2011-07-07 | Perforation |
2013-10-15 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-07-12 | 2011-07-12 | 6,704 | 4,367,255 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Clean Volume (gals) | Carrier/Base Fluid | 100.00 | 90.03 | ||||
Iron Control A | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00679000 | ||
CMHPG | Ashland | Water Viscosifier | Carboxymethylhydroxyporoyl guar blend | 100.00 | 0.00277000 | |||
Biocide EC 6116A | Nalco | Biocide | Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | ||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00114000 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00683000 | |||||
GBL | Clearwater International | Gel Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00004000 | ||
Scale Inhibitor A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00694000 | ||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.27 | |||
Unislik ST 50 | CESI Chemical | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
Proppant (lbs) | Proppant | 100.00 | 9.97 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 715,558.00 | 335 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 444,899.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 309,503.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 243,797.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 222,212.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 199,761.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 182,264.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 157,424.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 110.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2011 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 360.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2011 | CHEVRON APPALACHIA LLC | Produced Fluid | 180.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 3,379.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 930.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2011 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 21,294.30 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CHEVRON APPALACHIA LLC | Produced Fluid | 325.00 Bbl | IDENTIFY METHOD IN COMMENTS | 34-167-29359 |
2011 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 500.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 55.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2012 | CHEVRON APPALACHIA LLC | Produced Fluid | 6,194.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 630.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 0.30 Tons | LANDFILL | 100419 |
2012 | CHEVRON APPALACHIA LLC | Produced Fluid | 449.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,703.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 44.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 595.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 405.67 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 618.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 332.02 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 347.34 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil | 0.08 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,616.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW001 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 111.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | Soil Contaminated by Oil & Gas Related Spills | 0.08 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 74.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 221.67 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 216.66 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 331.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 396.67 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1929415 | Primary Facility | 2010-11-17 | Routine/Complete Inspection | No Violations Noted | Operator representatives Chad Eisenman and Nick Staffieri were present for the inspection. |
1939455 | Primary Facility | 2010-11-30 | Drilling/Alteration | No Violations Noted | YOST RIG FINISHED UP THE TOP HOLE ON THE HEPLER 1H AND SLIDE OVER TO THE HEPLER 2H. |
1939456 | Primary Facility | 2010-12-07 | Drilling/Alteration | No Violations Noted | YOST RIG DRILLING TOP HOLE ON THE HEPLER 3H |
1939459 | Primary Facility | 2010-12-15 | Drilling/Alteration | No Violations Noted | YOST RIG DRILLING TOP HOLE ON THE HEPLER 3H |
1939465 | Primary Facility | 2010-12-27 | Drilling/Alteration | No Violations Noted | NOMAC RIG RIGGING UP ON HEPLER 3H TO CONTINUE THE DRILLING. |
1940915 | Primary Facility | 2011-01-04 | Drilling/Alteration | No Violations Noted | NOMAC RIG CONTINUING DRILLING VERTICAL PORTION OF WELL, DEPTH 6312' |
1954909 | Primary Facility | 2011-02-18 | Routine/Complete Inspection | No Violations Noted | Routine inspection of site. |
1956059 | Primary Facility | 2011-02-04 | Drilling/Alteration | No Violations Noted | HORIZONTAL MARCELLUS |
1960343 | Primary Facility | 2011-03-22 | Drilling/Alteration | No Violations Noted | HORIZONAL MARCELLUS |
1994438 | Primary Facility | 2011-07-22 | Drilling/Alteration | No Violations Noted | ON 7/21/2011 @ 10:25PM DURING FLOW BACK THE WELL HAD SURGED CAUSING A 2" LINE TO LIFT 1500LD OF CEMENT BLOCKS AND INJURING A WORKER. |
2038272 | Primary Facility | 2012-01-31 | Routine/Complete Inspection | No Violations Noted | |
2153998 | Primary Facility | 2013-04-05 | Complaint Inspection | No Violations Noted | Met with Matt Reager with Chevron on site. Observed an E&S issue after a complainant pointed it out. |
2157227 | Primary Facility | 2013-04-16 | Follow-up Inspection | No Violations Noted | On 4/16/13 Sam Steingrabe conducted a follow up inspection at this site. Please read the above.Chevron repaired the erosional channel as requested. The repair looked great. |
2365112 | Primary Facility | 2015-04-28 | Routine/Complete Inspection | No Violations Noted | At the time of inspection the well was drilled and equipped for production. The well apparatus, brine tanks and gas production units appeared to be in sound condition. The site appaeres to be restored with good vegetative growth. No observation of accelerted erosion or sedmintaiton in realtion to the access road or well site. |
2474612 | Primary Facility | 2016-04-13 | Routine/Partial Inspection | No Violations Noted | At the time of inspection the well was drilled and equipped for production. The well apparatus, brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the access road or well site. See inspection #2474609 for additional observations regarding the site. |
2558599 | Primary Facility | 2017-02-02 | Routine/Partial Inspection | No Violations Noted | At the time of inspection, the well was drilled and equipped for production. The well apparatus, brine tanks and gas production units appeared to be in sound condition. No observation of accelerated erosion or sedimentation in relation to the access road or well site. |
For data sources see[8]