X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-28458

Well Details

Well ID: 37-129-28458
Loading map...
Operator Name: US ENERGY EXPLORATION CORP
First Permit Date: 2010-11-04
Last Permit Date: 2010-11-04
Spud Date: 2011-03-07
Unconventional: No
Horizontal: No
Violations: 2
Latitude: 40.521977
Longitude: -79.484386

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2011-0 0.0 0.0 0.0 0.0 0.0 0.0
2010-0 0.0 0.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1957612 2011-03-09 No Violations Noted Tripping back in hole (bit trip) at time of inspection. 6 1/4" hole at 2545' of proposed 3875' TD. Information per drillers log and cement tickets: 21' of 13 3/8" conductor set on 03-07-11. 928' of 20 lb/ft 7" casing set in 943' 8 7/8" hole and cemented with 130 sacks of 50/50 surface POZ containing 3% CACL2 & 1/4# flake & 0.3% FCP (yield=1.07 cu ft/sk); tailed by 50 sacks of "A" containing 3% CACL2 & 1/4# flake & 0.3% FCP (yield=1.18 cu ft/sk). Cement returns to surface not realized with plug landing at 10:22 03-08-11. Grouted backside of casing with basket set at 126'.

Met with Operator rep Cubby Stewart. Drilling pit lined and freeboard maintained. E/S controls in place and functioning as per available plan.

1957712 2011-03-10 No Violations Noted Running 4 1/2" production casing at time of inspection. TD = 3875'.

Discussed with Operator rep Cubby Stewart options per Chapter 78, Section 78.83b Casing and cementing - lost circulation. Drilling pit lined and freeboard maintained. E/S controls in place and functioning as per available plan

1960778 2011-03-22 No Violations Noted Water truck filling frack pit at time of inspection. Frack pit lined and freeboard maintained.

Well shut in on 4 1/2" x 2" swage. 7" x 4 1/2" annulus closed. E/S controls in place and functioning as per available plan.

1969376 2011-04-08 No Violations Noted Drilled, not equipped for production. Site ID sign and E&S plan located. Pit is on-site / in sound condition. An E&S concern was noted while on-site-

The culvert closest to the well site is draining directly into the silt fence on the lower side of the site. There is no where for the water to go. The operator was contacted and it was decided that a section of the silt fence will be replaced with a rock filter and additional rock protection will be added around the culvert.

1969384 2011-04-22 No Violations Noted Met with operator representative Harry Mills to check out improvements made to the E&S controls.

The operator has added additional rock protection to the culverts. IN addition, a section of the silt fence has been removed and replaced with a rock filter. The improvements look stable and should operate effectively.

Harry Mills also informed me that next week (weather permitting) they will add an additional load of clean, durable rock to further stabilize the area.

At this time, the site looks good. The operator has addressed all previously mentioned concerns.

1987126 2011-06-30 Violation(s) Noted Well shut-in on 4 1/2" x 2" swage.

7" x 4 1/2" annulus closed. Well site reclaimed, seeded, and mulched.


615150
2035133 2011-12-30 Violation(s) Noted Well in operation and properly identified. Well site reclaimed, seeded, and mulched.

Well equipped with separator, drip, meter, and produced fluids tank. Inspection conducted w/OGI D. Catalano. 7" x 4 1/2" annulus open and piped for production through regulator into separator. Operator did not install a working pressure gauge that can be inspected by the Department when utilizing surface casing, or any casing functioning as a water protection casing, as production casing. Well not in compliance with Chapter 78. Sections 78.83.(a)(2), 78.83.(j), 78.83b.(a)(3), and 78.86.

629625
2047162 2012-03-02 No Violations Noted Drilling had been completed on 03/10/11. Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site had been restored and the vegetative cover met the 70% uniform coverage criteria. It was noted that the well was located in a small pasture field.
2053761 2012-03-26 No Violations Noted Well appears to drilled and equipped for production. Well apparatus and brine tank located on site appear to be in sound condition. No observation of accelerated erosion on the well pad or access road noted. The site has been restored.