X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

Difference between revisions of "37-125-27926"

m
 
m
Line 3: Line 3:
 
{| class="wikitable welldetails" width="95%"
 
{| class="wikitable welldetails" width="95%"
 
| Well ID: 37-125-27926
 
| Well ID: 37-125-27926
| style="height=100%; align=center" rowspan="14" | {{#display_map: 40.0674, -80.396775 | width=100% | height=100% }}
+
| style="height=100%; align=center" rowspan="15" | {{#display_map: 40.0674, -80.396775 | width=100% | height=100% }}
 
|-
 
|-
 
| Country: United States
 
| Country: United States
Line 21: Line 21:
 
| License Status: Regulatory Inactive Status
 
| License Status: Regulatory Inactive Status
 
|-
 
|-
| Spud Date: 06/23/2017
+
| Spud Date: 2017-06-23
 
|-
 
|-
| Permit Date: 1/25/2017
+
| Permit Date: 2017-01-25
 
|-
 
|-
 
| Unconventional Well: Y
 
| Unconventional Well: Y
Line 49: Line 49:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
 +
<!--== Fracking Activities ==
 +
==== Fracking Jobs ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Job Start Date
 +
!scope="col" | Job End Date
 +
!scope="col" | True Vertical Depth (ft)
 +
!scope="col" | Total Water Volume (gal)
 +
!scope="col" | Total Non-Water Volume (gal)
 +
|-
 +
|}-->
 +
<!--==== Fluid Composition Data ====
 +
{| class="wikitable sortable" width="95%"
 +
!scope="col" | Job Number
 +
!scope="col" | Trade Name
 +
!scope="col" | Supplier
 +
!scope="col" | Purpose
 +
!scope="col" | Ingredient Name
 +
!scope="col" | CAS Number
 +
!scope="col" | Additive Percentage by Mass
 +
!scope="col" | Job Percentage by Mass
 +
!scope="col" | Mass Used (lb)
 +
|-
 +
|}-->
 +
 
== Production Data ==
 
== Production Data ==
 
{| class="wikitable sortable" width="95%"
 
{| class="wikitable sortable" width="95%"
Line 93: Line 118:
 
!scope="col" | Waste Facility ID
 
!scope="col" | Waste Facility ID
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Drill Cuttings (in Tons) RWC 810
 
| Drill Cuttings (in Tons) RWC 810
 
| style="text-align: right;" | 275.90 Tons
 
| style="text-align: right;" | 275.90 Tons
Line 99: Line 124:
 
| 100172
 
| 100172
 
|-
 
|-
| 2017-07
+
| 2017-M07
 
| Drill Cuttings (in Tons) RWC 810
 
| Drill Cuttings (in Tons) RWC 810
 
| style="text-align: right;" | 48.54 Tons
 
| style="text-align: right;" | 48.54 Tons
Line 105: Line 130:
 
| 100663
 
| 100663
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Drill Cuttings (in Tons) RWC 810
 
| Drill Cuttings (in Tons) RWC 810
 
| style="text-align: right;" | 295.69 Tons
 
| style="text-align: right;" | 295.69 Tons
Line 111: Line 136:
 
| 100172
 
| 100172
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Drill Cuttings (in Tons) RWC 810
 
| Drill Cuttings (in Tons) RWC 810
 
| style="text-align: right;" | 98.71 Tons
 
| style="text-align: right;" | 98.71 Tons
Line 117: Line 142:
 
| 100663
 
| 100663
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Drilling Fluid Waste (in Barrels) RWC 803
 
| Drilling Fluid Waste (in Barrels) RWC 803
 
| style="text-align: right;" | 5,590.00 Bbl
 
| style="text-align: right;" | 5,590.00 Bbl
Line 123: Line 148:
 
|  
 
|  
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| Other Oil & Gas Wastes (in Barrels) RWC 899
 
| style="text-align: right;" | 470.00 Bbl
 
| style="text-align: right;" | 470.00 Bbl
Line 129: Line 154:
 
|  
 
|  
 
|-
 
|-
| 2017-08
+
| 2017-M08
 
| Produced Fluid (in Barrels) RWC 802
 
| Produced Fluid (in Barrels) RWC 802
 
| style="text-align: right;" | 440.00 Bbl
 
| style="text-align: right;" | 440.00 Bbl
Line 263: Line 288:
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | url = http://wellwiki.org/wiki/Pennsylvania_Oil_and_Gas_Data_Sources
 
  | accessdate = 2019-05-21 }}</ref>
 
  | accessdate = 2019-05-21 }}</ref>
<!--== Fracking Activities ==
 
==== Fracking Jobs ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Job Start Date
 
!scope="col" | Job End Date
 
!scope="col" | True Vertical Depth (ft)
 
!scope="col" | Total Water Volume (gal)
 
!scope="col" | Total Non-Water Volume (gal)
 
|-
 
|}-->
 
<!--==== Fluid Composition Data ====
 
{| class="wikitable sortable" width="95%"
 
!scope="col" | Job Number
 
!scope="col" | Trade Name
 
!scope="col" | Supplier
 
!scope="col" | Purpose
 
!scope="col" | Ingredient Name
 
!scope="col" | CAS Number
 
!scope="col" | Additive Percentage by Mass
 
!scope="col" | Job Percentage by Mass
 
!scope="col" | Mass Used (lb)
 
|-
 
|}-->
 
 
 
==References==
 
==References==
 
<references/>
 
<references/>
 
__NOEDITSECTION__
 
__NOEDITSECTION__
 
[[Category:Pennsylvania Wells]]
 
[[Category:Pennsylvania Wells]]

Revision as of 14:01, 3 August 2019

Well Details

Well ID: 37-125-27926
Loading map...
Country: United States
State: Pennsylvania
County: Washington
Municipality: East Finley Township
Operator Name: EQT PROD CO
Well Pad ID: 153510
Farm/Lease Name: JT FARM 593015
License Status: Regulatory Inactive Status
Spud Date: 2017-06-23
Permit Date: 2017-01-25
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 40.0674
Longitude: -80.396775

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 EQT PROD CO 0.00 0 0.00 0 0.00 0
2019 EQT PROD CO 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2017-M07 Drill Cuttings (in Tons) RWC 810 275.90 Tons LANDFILL 100172
2017-M07 Drill Cuttings (in Tons) RWC 810 48.54 Tons LANDFILL 100663
2017-M08 Drill Cuttings (in Tons) RWC 810 295.69 Tons LANDFILL 100172
2017-M08 Drill Cuttings (in Tons) RWC 810 98.71 Tons LANDFILL 100663
2017-M08 Drilling Fluid Waste (in Barrels) RWC 803 5,590.00 Bbl REUSE (AT WELL PAD)
2017-M08 Other Oil & Gas Wastes (in Barrels) RWC 899 470.00 Bbl REUSE (AT WELL PAD)
2017-M08 Produced Fluid (in Barrels) RWC 802 440.00 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2586322 Primary Facility 2017-04-17 Routine/Complete Inspection No Violations Noted On 4/17/2017, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was performed as a routine inspection during construction of the site.

The Act 9 site ID sign was in place and legible.

The access road to the well pad has been constructed. The operator has completed construction of the southeast section of the well pad and fill slope. During the inspection the operator was in process of constructing the toe key for the northwest well pad fill slope.

All perimeter E&S BMPs have been installed for the access road and well pad which are functional. The trees have been cleared for the entire site and the operator was in process of installing E&S BMPs for the AST pad and freshwater impoundment.

5 wells have been permitted to be drilled on site.

2608268 Primary Facility 2017-06-26 Drilling/Alteration No Violations Noted Operator reports 30" hole drilled to 40' with 26" conductor grouted to surface through 1" tubing. Site inspection shows no apparent viloation. NOVIO
2615059 Primary Facility 2017-06-01 Preoperation Inspection No Violations Noted On June 1, 2017, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was performed as a pre-operational inspection during construction of the site before the commencement of drilling.

The Act 9 site ID sign was in place and legible.

The access road to the well pad has been constructed. The operator has completed construction of the well pad and fill slope. During the inspection the operator was in process of stoning the pad in preparation of drilling on site. The operator has started construction of the freshwater impoundment for the site.

All perimeter E&S BMPs have been installed for the site and are functional.

5 wells have been permitted to be drilled on site.

2618303 Primary Facility 2017-07-21 Routine/Complete Inspection No Violations Noted Operator reports 18 5/8" csg set at 553' with 30 Bbls of cement returns. NOVIO
2679924 Primary Facility 2018-01-03 Routine/Complete Inspection No Violations Noted On January 3, 2018, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was a routine inspection before resumption of drilling activity on the site.

The site was covered with snow at time of inspection. The access road and well pad are in good condition. The operator has begun filing the freshwater impoundment on site. PCSM structures have not been installed, and all E&S BMPs have been installed and are functional.

The operator has permitted 12 wells on site and has drilled the vertical section for five of these wells. The operator plans to revisit the site spud the remaining seven permitted wells for the site and complete drilling operations to TD for all 12 permitted wells for the site.

5 Spud wells with vertical section of well drilled. JT Farm 593014 JT Farm 593015 JT Farm 593016 JT Farm 593017 JT Farm 593018

7 permitted but not drilled wells. JT Farm 593019 JT Farm 593020 JT Farm 593021 JT Farm 593022

2833319 Primary Facility 2019-01-10 Routine/Complete Inspection No Violations Noted On January 10, 2019, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was related to a request by the operator for a minor modification to the ESCGP2 permit.

The operator has requested a minor modification to the ESCGP2 permit to construct a fresh water pipeline, and gathering pipeline within the well pad LOD to connect to the Equitrans NIPI-S002 pipeline site. The minor modification was reviewed and approved by the Department in the field. The modified ESCGP2, E&S plans were redlined by the Department and left in the mailbox on site as the official plans for the site.

The well pad and access road where in good condition.

The operator plans to return to the site in the near future to complete drilling operations for the 12 permitted wells on the site. 5 wells have the vertical sections for those wells completed and are on inactive status at this current time.

For data sources see[6]

References