{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.228997,"lon":-80.031939,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Nottingham Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149501 | |
Farm/Lease Name: HARBISON 592999 | |
License Status: Active | |
Spud Date: 2015-04-08 | |
Permit Date: 2014-10-17 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.228997 | |
Longitude: -80.031939 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-10-10 | 2015-10-13 | 7614 | 4,601,600.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 89.1129 | 38,400,400.0 |
CS-500-SI | FTS International | Scale inhibitor | Ethylene glycol | 107-21-1 | 10 | 0.00247236 | 1065.39 | |
FE-100L | FTS International | Iron control | Citric acid | 77-92-9 | 55 | 0.000754097 | 324.954 | |
MC MX 437-5 | Multi-Chem Group LLC | Calcium nitrate solution | Calcium nitrate | 10124-37-5 | 60 | 0.0567716 | 24463.9 | |
Sand (Proppant) | FTS International | Proppant | Silica Substrate | 14808-60-7 | 100 | 10.4933 | 4,521,750.0 | |
Hydrochloric Acid (15%) | FTS International | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0326359 | 14063.4 | |
CI-150 | FTS International | Acid corrosion inhibitor | Dimethylformamide | 68-12-2 | 10 | 0.00004026 | 17.349 | |
Ethylene glycol | 107-21-1 | 30 | 0.000120783 | 52.048 | ||||
Organic amine resin salt | Proprietary | 30 | 0.000120783 | 52.048 | ||||
Quaternary ammonium compound | Proprietary | 10 | 0.00004026 | 17.349 | ||||
Aromatic aldehyde | Proprietary | 10 | 0.00004026 | 17.349 | ||||
Isopropanol | 67-63-0 | 30 | 0.000120783 | 52.048 | ||||
FRW-900 | FTS International | Friction reducer | Oxyalkylated alcohol A | Proprietary | 5 | 0.00273712 | 1179.47 | |
Hydrotreated light distillate | 64742-47-8 | 30 | 0.0164227 | 7076.85 | ||||
Alkyl alcohol | Proprietary | 10 | 0.00547424 | 2358.95 | ||||
NE-100 | FTS International | Non-emulsifier | Dodecylbenzenesulfonic acid | 27176-87-0 | 5 | 0.00001821 | 7.848 | |
2-Propanol | 67-63-0 | 10 | 0.00003643 | 15.697 | ||||
2-Butoxyethanol | 111-76-2 | 10 | 0.00003643 | 15.697 | ||||
Methanol | 67-56-1 | 15 | 0.00005464 | 23.545 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 649,534.00 | 147 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 583,666.00 | 288 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 289,045.00 | 303 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 62,823.00 | 74 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2015-S01 | Drill Cuttings (in Tons) | 15.00 Tons | LANDFILL | 100172 |
2015-S01 | Drill Cuttings (in Tons) | 54.00 Tons | LANDFILL | 100592 |
2015-S01 | Drill Cuttings (in Tons) | 317.00 Tons | LANDFILL | 100663 |
2015-S02 | Drill Cuttings (in Tons) | 332.79 Tons | LANDFILL | 100172 |
2015-S02 | Drill Cuttings (in Tons) | 210.84 Tons | LANDFILL | 100663 |
2015-S02 | Drilling Fluid Waste (in Barrels) | 470.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracing Fluid Waste (in Barrels) | 3,380.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Fracturing Fluid Waste (in Tons) | 23.14 Tons | LANDFILL | 100277 |
2015-S02 | Fracturing Fluid Waste (in Tons) | 95.22 Tons | LANDFILL | 100592 |
2015-S02 | Fracturing Fluid Waste (in Tons) | 24.38 Tons | LANDFILL | 101571 |
2016-S01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 25.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 160.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Servicing Fluid (in Tons) RWC 808 | 110.00 Tons | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Fracturing Fluid Waste (in Barrels) RWC 805 | 270.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016-S02 | Fracturing Fluid Waste (in Barrels) RWC 805 | 130.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 298.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 6,077.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Synthetic Liner Materials (in Tons) RWC 806 | 15.73 Tons | LANDFILL | 100419 |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 520.00 Bbl | REUSE (AT WELL PAD) | |
2017-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 20.00 Bbl | REUSE (AT WELL PAD) | |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 130.00 Bbl | REUSE (AT WELL PAD) | |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 218.00 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 167.00 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 418.00 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 370.00 Bbl | REUSE (AT WELL PAD) | |
2017-M06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 390.00 Bbl | REUSE (AT WELL PAD) | |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 260.00 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 10.00 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 450.00 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 570.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 110.00 Bbl | REUSE (AT WELL PAD) | |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 3,130.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M01 | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 26.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 77.29 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 28.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 1.00 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 10.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 5.16 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 5.63 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 42.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M04 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 16.50 Bbl | REUSE (AT WELL PAD) | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 2.81 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 16.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M05 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 5.27 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M06 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 0.95 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 17.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 29.44 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 0.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 9.25 Bbl | REUSE (AT WELL PAD) | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 0.14 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 0.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 35.27 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 1.42 Bbl | REUSE (AT WELL PAD) | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 0.45 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M10 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 11.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018-M10 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 0.75 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 4.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 11.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 1.42 Bbl | REUSE (AT WELL PAD) | |
2018-M10 | Produced Fluid (in Barrels) RWC 802 | 35.55 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 1.75 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 2.36 Bbl | REUSE (AT WELL PAD) | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 1.72 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M12 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 8.75 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 0.73 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 6.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 0.36 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 1.46 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M01 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 34.50 Bbl | REUSE (AT WELL PAD) | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 308.70 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | ORDER 2016-415 |
2019-M02 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 5.50 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 4.62 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 3.21 Bbl | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2014-4 |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 62.40 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 16.79 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 96.50 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 0.36 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 19.62 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2365898 | Primary Facility | 2015-04-09 | Drilling/Alteration | No Violations Noted | Himes Diversified auger rig |
2410194 | Primary Facility | 2015-08-28 | Routine/Complete Inspection | No Violations Noted | On 8/28/15, I performed a routine inspection on the Vivian Harbison site and made the following observations: |
2602690 | Primary Facility | 2017-06-07 | Routine/Complete Inspection | No Violations Noted | |
2685495 | Primary Facility | 2018-01-10 | Administrative/File Review | No Violations Noted | Operator servicing well and preparing containment. |
2700227 | Primary Facility | 2018-02-26 | Routine/Complete Inspection | No Violations Noted | This well has been completed and is now producing. |
2720054 | Primary Facility | 2018-04-19 | Incident- Response to Accident or Event | In Compliance with Policy | On 4/19/18 an incident inspection of the Vivian Harbison Well Site was conducted in response to CTS ID: 333587. The following was observed:
>>On 4/13/18 EQT's Mike Cromley reported a ten gallon spill with cleanup beginning immediately as a vacc truck was present on site at the time of the spill. >>Further communication with operator personnel indicated a spill of 10 gallons of produced water near the offloading point near the production tanks and that the spill cleanup was completed the same day. >>Site inspection found no visible evidence of contamination, cleanup appears to have been fully completed in compliance with policy. |