If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-24331 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.055547,"lon":-80.134542,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: West Bethlehem Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148469 | |
Farm/Lease Name: HAMBLETON UNIT 2H | |
License Status: Active | |
Spud Date: 01/23/2011 | |
Permit Date: 12/3/2010 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 40.055547 | |
Longitude: -80.134542 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 155,417.00 | 122 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 2,144,593.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 1,216,541.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 886,131.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 696,748.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 568,529.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 490,381.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 110,324.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2011-1 | Drilling Fluid Waste (in Barrels) | 425.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 301353 |
2011-1 | Drilling Fluid Waste (in Barrels) | 1,720.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0091472 |
2011-1 | Drilling Fluid Waste (in Barrels) | 220.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0095273 |
2011-2 | Drilling Fluid Waste (in Barrels) | 10,522.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-1 | Fracing Fluid Waste (in Barrels) | 6,263.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Fracing Fluid Waste (in Barrels) | 3,137.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-2 | Fracing Fluid Waste (in Barrels) | 10,969.10 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Fracturing Fluid Waste (in Tons) | 69.44 Tons | LANDFILL | 100172 |
2012-2 | Produced Fluid (in Barrels) | 213.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Fracturing Fluid Waste (in Tons) | 59.08 Tons | LANDFILL | 100172 |
2013-1 | Produced Fluid (in Barrels) | 3,642.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 1,806.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 86.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-1 | Produced Fluid (in Barrels) | 1,483.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Produced Fluid (in Barrels) | 794.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 60.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2015-1 | Produced Fluid (in Barrels) | 644.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Fracing Fluid Waste (in Barrels) | 24.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015-2 | Fracturing Fluid Waste (in Tons) | 0.47 Tons | LANDFILL | 100172 |
2015-2 | Produced Fluid (in Barrels) | 581.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 24.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 663.12 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Fracturing Fluid Waste (in Barrels) RWC 805 | 1.60 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 285.21 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 93.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 100.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 75.44 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 48.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 1,008.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 2,016.00 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 92.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 42.00 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 43.40 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 24.00 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 65.87 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 43.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 134.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 66.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 65.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 152.00 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 23.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 64.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 41.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 69.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 62.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 68.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1953716 | Primary Facility | 01/23/2011 | Drilling/Alteration | No Violations Noted | Rocky Mountian Drilling - spud conductor , site still under construction , E&S in place |
1976560 | Primary Facility | 04/28/2011 | Drilling/Alteration | No Violations Noted | Crown 5 - TD@ 1493, drilling 107/8 hole site and location good, pit good, basket at 735 on 11 3/4. |
1983604 | Primary Facility | 05/12/2011 | Drilling/Alteration | No Violations Noted | Crown 5 - TD@ 3075, Tripping back in hole for fish, ( 3 joints, motor , BHA) , Site and location good, pit good |
1999335 | Primary Facility | 05/20/2011 | Complaint Inspection | No Violations Noted | |
2065439 | Primary Facility | 04/06/2012 | Incident- Response to Accident or Event | No Violations Noted | viols linked to 5H eFacts ID #2065442, enforcement ID #283685. |
2065939 | Primary Facility | 04/09/2012 | Incident- Response to Accident or Event | No Violations Noted | viols for this inspection linked to 1H inspection # 2065932 |
2069699 | Primary Facility | 05/02/2012 | Compliance Evaluation | No Violations Noted | |
2080023 | Primary Facility | 06/26/2012 | Drilling/Alteration | No Violations Noted | |
2080820 | Primary Facility | 06/19/2012 | Routine/Complete Inspection | No Violations Noted | On June 19, 2012, I stopped at the Chevron’s Hambelton site for a routine inspection. The site has five stimulated wells but is not yet in production. |
2080855 | Primary Facility | 07/03/2012 | Follow-up Inspection | No Violations Noted | viols from the 4/9/12 release (eFACTS #2065934) have been corrected. |
2129944 | Primary Facility | 10/03/2012 | Complaint Inspection | No Violations Noted | I did a preliminary investigation and gathered background and historical information but was unable to sample because Mr. Hutchinson was not available to work the plumbing. I made preliminary plans to sample and left. |
2129995 | Primary Facility | 12/06/2012 | Complaint Inspection | No Violations Noted | Scheduling conflicts made sampling difficult. On December 6, 2012 I again, stopped at the Hutchison residence and made arrangements to sample the water. |
2129999 | Primary Facility | 12/06/2012 | Complaint Inspection | No Violations Noted | Scheduling conflicts made sampling difficult. On December 6, 2012 I again, stopped at the Hutchison residence and made arrangements to sample the water. |
2130051 | Primary Facility | 12/12/2012 | Complaint Inspection | No Violations Noted | Scheduling conflicts made sampling difficult. On December 6, 2012 I again, stopped at the Hutchison residence and made arrangements to sample the water. |
2130077 | Primary Facility | 01/14/2013 | Administrative/File Review | No Violations Noted | I received the various lab results and checked them against Moody's (Chevron's enviromental contractor) report. It does nto appear that the Hambleton gas wells impacted theHutchison's water supply. See attached report. |
2295974 | Primary Facility | 07/24/2014 | Routine/Complete Inspection | No Violations Noted | Inspection of well - tag should be upgraded - difficult to find and illegible. Site appears to be restored and is stabilized. All temporary E&S controls have been removed. |
2296001 | Primary Facility | 08/12/2014 | Follow-up Inspection | No Violations Noted | Well tag placed in a conspicuous area on the well head and is legible. Site is restored and stable. |
2417330 | Primary Facility | 10/14/2015 | Routine/Complete Inspection | No Violations Noted | On 10/14/15, I performed a routine complete inspection on the Hambleton Unit and made the following observations: |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 05/10/2012 | 05/10/2012 | 7018.00 | 6,315,885.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00397000 | |
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.27 | |||
Biocide EC 6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00738000 | ||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00123000 | |||||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00727000 | ||
Proppant (lbs) | Proppant | 7.89 | 8.49 | |||||
Clean Volume (gals) | Carrier/Base Fluid | 92.11 | 100.00 | |||||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00682000 | ||
GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00002000 | ||
Carbohydrates | 95.00 | 0.00012000 |
For data sources see[7]