37-115-21138

Well Details

Well ID: 37-115-21138
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 146094
Farm/Lease Name: EMPET D 4
License Status: Active
Spud Date: 03/24/2013
Permit Date: 2/4/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.739144
Longitude: -75.710361

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 3,763,185.06 192 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 3,920,135.83 352 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,972,675.17 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,547,847.13 364 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,116,649.70 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 870,671.00 291 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2013-1 Drill Cuttings (in Tons) 1,117.08 Tons LANDFILL 101247
2013-1 Drill Cuttings (in Tons) 231.34 Tons LANDFILL THR029
2013-1 Drilling Fluid Waste (in Barrels) 660.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013-1 Fracing Fluid Waste (in Barrels) 351.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013-1 Fracing Fluid Waste (in Barrels) 11,619.31 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013-2 Produced Fluid (in Barrels) 15.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013-2 Produced Fluid (in Barrels) 10,097.29 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014-1 Produced Fluid (in Barrels) 1,171.15 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014-2 Produced Fluid (in Barrels) 657.51 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015-1 Produced Fluid (in Barrels) 7.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2015-1 Produced Fluid (in Barrels) 400.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015-2 Produced Fluid (in Barrels) 317.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016-1 Produced Fluid (in Barrels) RWC 802 272.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016-2 Produced Fluid (in Barrels) RWC 802 260.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-01 Produced Fluid (in Barrels) RWC 802 10.65 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-01 Produced Fluid (in Barrels) RWC 802 5.16 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-02 Produced Fluid (in Barrels) RWC 802 19.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-02 Produced Fluid (in Barrels) RWC 802 19.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-03 Produced Fluid (in Barrels) RWC 802 9.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017-03 Produced Fluid (in Barrels) RWC 802 30.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-04 Produced Fluid (in Barrels) RWC 802 48.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-05 Produced Fluid (in Barrels) RWC 802 29.54 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-06 Produced Fluid (in Barrels) RWC 802 36.46 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-07 Produced Fluid (in Barrels) RWC 802 41.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017-09 Produced Fluid (in Barrels) RWC 802 38.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-10 Produced Fluid (in Barrels) RWC 802 6.02 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-11 Produced Fluid (in Barrels) RWC 802 27.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017-12 Produced Fluid (in Barrels) RWC 802 21.35 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-01 Produced Fluid (in Barrels) RWC 802 21.83 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-02 Produced Fluid (in Barrels) RWC 802 33.15 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-03 Produced Fluid (in Barrels) RWC 802 22.59 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-04 Produced Fluid (in Barrels) RWC 802 20.49 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-05 Produced Fluid (in Barrels) RWC 802 15.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-05 Produced Fluid (in Barrels) RWC 802 15.19 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-06 Produced Fluid (in Barrels) RWC 802 21.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-07 Produced Fluid (in Barrels) RWC 802 21.31 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018-07 Produced Fluid (in Barrels) RWC 802 7.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-08 Produced Fluid (in Barrels) RWC 802 34.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-09 Produced Fluid (in Barrels) RWC 802 32.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018-10 Produced Fluid (in Barrels) RWC 802 112.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2164216 Primary Facility 05/03/2013 Drilling/Alteration No Violations Noted Precision 538 moving off location. Unable to access wellhead. will return at later time to inspect wellheads once heavy equipment off location
2164217 Primary Facility 05/07/2013 Routine/Complete Inspection No Violations Noted Crews onsite setting up equipment to perform pressure tests.
2476160 Primary Facility 2016-04-19 Routine/Complete Inspection No Violations Noted
2500367 Primary Facility 2016-07-07 Routine/Complete Inspection No Violations Noted
2579225 Primary Facility 2017-04-04 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:25a.m.

The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting to the production tank, the (9x5) annulus vent pipe was open and venting to the production tank. There was 492psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 12:05p.m.

2677943 Primary Facility 2017-12-20 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The (20x13) annulus was below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2769368 Primary Facility 2018-08-30 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 6' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same production tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2831481 Primary Facility 2019-01-16 Incident- Response to Accident or Event No Violations Noted I arrived at the site at 9:43 in response to a report of staining discovered on the pad surface as Cabot was in the process of removing the secondary containment liner user for drilling operations. I was accompanied by Gene Rickard, DEP O&G WQS out of the Scranton District Office. The weather conditions are cloudy skies, cold, with light winds, and temperatures in the 30's. Cabot was in the process of rigging down the site. Precision Drilling Rig # 181 has recently demobilized from the site. Cabot submitting Drilling resumption After Break of 30 days or more notifications to the Department for the Empet 3H, 5H, 6H, 7H, 10H and 12H wells. The notifications were submitted on 12/4/18, 12/13/18, 12/14/18, and 12/15/18. The 1H, 2H, 4H, and 8H are the existing wells on the pad, but are currently shut in. The production equipment for these wells has been moved to the tank pad section of the site. We met with Eric Peterson, Drilling Environmental Health and Safety Consultant of Cabot Oil and Gas. Cabot was in
2847228 Primary Facility 2019-02-26 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 05/22/2013 06/09/2013 7121 10,732,700.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 40/70 White FTSI Proppant 40/70 White na 100 10.5872 0
FE-100L FTSI Iron control Citric acid 77-92-9 55 0.00096 0
Water 7732-18-5 60 0.00104 0
100 Mesh Sand FTSI Proppant 100 Mesh Sand na 100 0.59107 0
BIO-3240 FTSI Biocide Sodium Hydroxide 1310-73-2 23 0.00698 0
Water 7732-18-5 55 0.01668 0
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1, 3, 5-thiadiazine-2-thione. 533-74-4 24 0.00728 0
APB-1 FTSI Gel breaker Ammonium Persulfate 7727-54-0 100 0.00013 0
CI-150 FTSI Acid Corrosion Inhibitor Water 7732-18-5 5 0.00005000 0
Aliphatic alcohol Proprietary 0.1 0.00001000 0
Aromatic aldehyde Proprietary 10 0.0001 0
Ethylene Glycol 107-21-1 30 0.00029 0
Organic amine resin salt Proprietary 30 0.00029 0
Dimethylformamide 68-12-2 10 0.0001 0
Isopropanol 67-63-0 30 0.00029 0
Quaternary ammonium compound Proprietary 10 0.0001 0
Diethylene glycol 111-46-6 1 0.00001000 0
Fatty Acid Proprietary 0.1 0.00001000 0
Fatty Acid Salt Proprietary 0.1 0.00001000 0
Alkylene Oxide Block Polymer Proprietary 10 0.0001 0
FRW-200 FTSI Friction reducer Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.00343 0
Acrylamide 79-06-1 0.1 0.00009000 0
Water 7732-18-5 48 0.0412 0
Proprietary Component Proprietary 1.5 0.00129 0
Petroleum distillate hydrotreated light 64742-47-8 26 0.02232 0
Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.02146 0
Sorbitol Tetraoleate 61723-83-9 2 0.00172 0
Surfactant Proprietary 7 0.00601 0
Sorbitan Monooleate 1338-43-8 3 0.00257 0
Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.00343 0
Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.00086 0
Polyethylene glycol monooleate 9004-96-0 3 0.00257 0
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.00343 0
Ammonium Chloride 12125-02-9 12 0.0103 0
Ammonium Acrylate 10604-69-0 0.5 0.00043 0
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.02832 0
CS-500 SI FTSI Scale inhibitor Sodium Polyacrylate 9003-04-7 5 0.0015 0
Ethylene glycol 107-21-1 10 0.003 0
Acrylic Polymer Proprietary 0 0 0
Sodium chloride 7647-14-5 6 0.0018 0
Water 7732-18-5 55 0.01649 0
HVG-1 FTSI Water Gelling Agent Guar Gum 9000-30-0 50 0.00162 0
Surfactant 68439-51-0 2 0.0006 0
Ethylene glycol monobutyl ether 111-76-2 0.25 0.00001000 0
Clay 14808-60-7 2 0.00006000 0
Petroleum Distillate 64742-47-8 55 0.00179 0
Water Operator Carrier Water 7732-18-5 100 88.1208 0
Hydrochloric Acid (HCl) FTSI Acid Water 7732-18-5 85 0.46643 0
Hydrogen Chloride 7647-01-0 15 0.08231 0

For data sources see[7]