If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20164 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.729919,"lon":-75.908628,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Dimock Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 147751 | |
Farm/Lease Name: B SEVERCOOL 2H NW | |
License Status: | |
Spud Date: | |
Permit Date: 2009-04-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.729919 | |
Longitude: -75.908628 |
Date | Event |
---|---|
2009-04-30 | New Permit Application |
2009-06-10 | Performed Spud Operation |
2009-08-08 | Perforation |
2009-08-08 | Performed Stimulation |
2009-08-26 | Drilling Completion |
2012-02-06 | DEVIATED |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2009-08-08 | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | CABOT OIL & GAS CORP | 173370.00 | 51 | 0.00 | 0 | 0.00 | 0 |
2010 | CABOT OIL & GAS CORP | 765,990.50 | 297 | 0.00 | 0 | 0.00 | 0 |
2011 | CABOT OIL & GAS CORP | 669,168.35 | 358 | 0.00 | 0 | 0.00 | 0 |
2012 | CABOT OIL & GAS CORP | 509,360.24 | 365 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 288,151.79 | 240 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 349,221.03 | 322 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 188,750.29 | 330 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 249,089.52 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 193,050.78 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 151,693.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 130,760.00 | 359 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 215.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2010 | CABOT OIL & GAS CORP | Produced Fluid | 154.32 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2010 | CABOT OIL & GAS CORP | Basic Sediment | 2.59 Bbl | LANDFILL | 101534 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 129.40 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 65.10 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 101247 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 18.40 Tons | LANDFILL | NY # 50S08 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 105.90 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 8-4630-00010/00 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 858.80 Tons | LANDFILL | THR029 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 105.90 Tons | LANDFILL | NY # 02S17 |
2010 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 238.10 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0008451 |
2010 | CABOT OIL & GAS CORP | Drill Cuttings | 17.40 Tons | LANDFILL | 100955 |
2011 | CABOT OIL & GAS CORP | Basic Sediment | 0.56 Bbl | LANDFILL | 101534 |
2011 | CABOT OIL & GAS CORP | Produced Fluid | 156.77 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Produced Fluid | 69.74 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 0.23 Bbl | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Basic Sediment | 0.43 Bbl | LANDFILL | 101534 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 200.54 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 309.14 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 6.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 517.47 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 102.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 10.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 75.27 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 56.73 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 52.88 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 68.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 0.35 Tons | LANDFILL | 101247 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 87.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 48.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 140.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1806417 | Primary Facility | 2009-06-18 | Drilling/Alteration | No Violations Noted | SWJ Rig-19 on Site. Drilling depth at time of inspection was 911'. Surface casing (9-5/8) set at 911'. Conductor (16")set at 60'. Drilling crew was installing B.O.P. Freeboard in pit was 5-6'. E/S controls in place and working properly. |
1811415 | Primary Facility | 2009-07-07 | Drilling/Alteration | No Violations Noted | Drill rig on site is SWJ-19. Depth of drilling at time of inspection was 7332'. According to Company Man, the crew is drilling with mud using a 6-1/4 PDC bit. Crew will be drilling to a TD of 9534 and will set 4-1/2 casing at this depth. Drillers log was inspected and was filled out properly. |
1819275 | Primary Facility | 2009-08-06 | Drilling/Alteration | No Violations Noted | Drill rig on site was SWJ-19. Depth of drilling at time of inspection was 9500'. At the time of inspection, the drilling contractor was cleaning out the hole. After trippin out of the hole, 4-1/2 production casing will be set. The Company Man was not on-site at the time of inspection. |
1825895 | Primary Facility | 2009-08-27 | Routine/Complete Inspection | Violation(s) Noted | My inspection revealed an un-permitted discharge of drilling mud occurred at the site while handling and transporting drilling hoses on location. This discharge is a violation of Chapter 78.54 of the Rules and Regulations of the Environmental Quality Board, 25 Pa. code, 78.54. |
1841277 | Primary Facility | 2009-10-30 | Follow-up Inspection | No Violations Noted | At the time of inspection, FracTech was on site preparing for the second stage of the frac job on the well. Upon arriving on location, the crew was addressing a diesel spill near one of the pump trucks on location. The diesel spill occurred from an overfilled saddle tank. Approximately 5 gallons of diesel appeared to have spilled onto the secondary containment ¿duck pond¿ located underneath the truck. The spill was contained within the containment area, and immediately cleaned up, and prevented from reaching the ground. |
1844993 | Primary Facility | 2009-10-19 | Follow-up Inspection | No Violations Noted | No activity on site. Well installation is completed and is scheduled to be fracced in near future. Cellar of well has water in it. There were no visible signs of gas leaking around the well head. No bubbling observed in cellar. |
1846138 | Primary Facility | 2009-10-27 | Routine/Complete Inspection | No Violations Noted | |
1846150 | Primary Facility | 2009-10-28 | Routine/Complete Inspection | No Violations Noted | |
1849752 | Primary Facility | 2009-12-10 | Follow-up Inspection | No Violations Noted | : No activity on site. Well installation is completed. Cellar of well has water in it. There were no visible signs of gas leaking around the well head. No bubbling observed in cellar. Reserve pits have been reclaimed. The well is online. |
1890373 | Primary Facility | 2010-05-24 | Routine/Complete Inspection | No Violations Noted | |
1905492 | Primary Facility | 2010-07-27 | Drilling/Alteration | No Violations Noted | |
1978308 | Primary Facility | 2011-06-01 | Routine/Complete Inspection | No Violations Noted | |
2395714 | Primary Facility | 2015-08-05 | Routine/Complete Inspection | No Violations Noted | |
2430997 | Primary Facility | 2015-12-04 | Site Restoration | No Violations Noted | Inspection of the Severcool B P1 Well Pad in response to a submitted Notice of Termination request for the Erosion and Sedimentation Control Permit. |
2496265 | Primary Facility | 2016-06-23 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 9:30a.m., the cellar was full of water with no bubbling noticed, the (9x4) vent pipe was open and venting to a tank, there was 511psi on the production casing. I took a walk around the location and everything looked OK.
I left the site at 10:15a.m. |
2566394 | Primary Facility | 2017-03-01 | Routine/Complete Inspection | No Violations Noted | Site is stable and small, on gently sloping ground and is well vegetated. There are a line of coniferous trees between pad and nearby house which are healthy. There are no erosional problems evident at this time.
There are no violations. If there are any questions feel free to contact me at 570-346-5539 |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1825895 | 570860 | 08/27/2009 | 2009-08-27 | 301 - Failure of storage operator to maintain and/or submit required information, such as maps, well records, integrity testing informatio, pressure data | Administrative | FUI conducted 9/10/09 found prior drill mud spill adequately cleaned up, cited 8/27/09 viols closed. |
1825895 | 570861 | 08/27/2009 | 2009-08-27 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | FUI conducted 9/10/09 found prior drill mud spill adequately cleaned up, cited 8/27/09 viols closed. |
For data sources see[8]