37-115-20164

Well Details

Well ID: 37-115-20164
Loading map...
County: Susquehanna
Municipality: Dimock Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 147751
Farm/Lease Name: B SEVERCOOL 2H NW
First Permit Date: 2009-04-30
Last Permit Date: 2009-04-30
Spud Date: 2009-06-10
Unconventional: Yes
Horizontal: Yes
Producing: Yes
Violations: 2
Latitude: 41.729919
Longitude: -75.908627

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID
1806417 2009-06-18 No Violations Noted SWJ Rig-19 on Site. Drilling depth at time of inspection was 911'. Surface casing (9-5/8) set at 911'. Conductor (16")set at 60'. Drilling crew was installing B.O.P. Freeboard in pit was 5-6'. E/S controls in place and working properly.


1811415 2009-07-07 No Violations Noted Drill rig on site is SWJ-19. Depth of drilling at time of inspection was 7332'. According to Company Man, the crew is drilling with mud using a 6-1/4 PDC bit. Crew will be drilling to a TD of 9534 and will set 4-1/2 casing at this depth. Drillers log was inspected and was filled out properly.

All E/S controls were in place and functioning properly. Freeboard in pit 1 was approximately 3', and pit 2 was approximately 10'. Liners in pits appeared to be in good condition at time of inspection.

1819275 2009-08-06 No Violations Noted Drill rig on site was SWJ-19. Depth of drilling at time of inspection was 9500'. At the time of inspection, the drilling contractor was cleaning out the hole. After trippin out of the hole, 4-1/2 production casing will be set. The Company Man was not on-site at the time of inspection.

There are currently two reserve pits located on site. One of the pits is located near the entrance to the well pad. At the time of inspection, the freeboard level in this pit was at the 2' level. The second pit, which is a tiered pit containing the shaker unit, and is located at the rear of the well pad. The freeboard in this pit at the time of inspection was aproximately 4'. Liners in both pits appeared to be in good condition at time of inspection. All E/S controls were in place and functioning properly.

1825895 2009-08-27 Violation(s) Noted My inspection revealed an un-permitted discharge of drilling mud occurred at the site while handling and transporting drilling hoses on location. This discharge is a violation of Chapter 78.54 of the Rules and Regulations of the Environmental Quality Board, 25 Pa. code, 78.54.

My inspection also revealed that drilling fluids were allowed to be released onto the ground which flowed across the well pad and over the well pad embankment. This un-permitted discharge of residual waste is a violation of Section 301 of the Solid Waste Management Act, 35 P.S. 6018.301 See inspection report for more details.

570860
1825895 2009-08-27 Violation(s) Noted My inspection revealed an un-permitted discharge of drilling mud occurred at the site while handling and transporting drilling hoses on location. This discharge is a violation of Chapter 78.54 of the Rules and Regulations of the Environmental Quality Board, 25 Pa. code, 78.54.

My inspection also revealed that drilling fluids were allowed to be released onto the ground which flowed across the well pad and over the well pad embankment. This un-permitted discharge of residual waste is a violation of Section 301 of the Solid Waste Management Act, 35 P.S. 6018.301 See inspection report for more details.

570861
1841277 2009-10-30 No Violations Noted At the time of inspection, FracTech was on site preparing for the second stage of the frac job on the well. Upon arriving on location, the crew was addressing a diesel spill near one of the pump trucks on location. The diesel spill occurred from an overfilled saddle tank. Approximately 5 gallons of diesel appeared to have spilled onto the secondary containment ¿duck pond¿ located underneath the truck. The spill was contained within the containment area, and immediately cleaned up, and prevented from reaching the ground.

Prior to commencing the frac, FracTech completed a hydrostatic pressure test. During the initial pressure test, a small leak in one of the pipe connections was observed. The seal on the fitting was replaced, and the system was re-tested and passed. The second stage of the frac was completed over an approximate 3-hour period. During the frac no incidences occurred.

1844993 2009-10-19 No Violations Noted No activity on site. Well installation is completed and is scheduled to be fracced in near future. Cellar of well has water in it. There were no visible signs of gas leaking around the well head. No bubbling observed in cellar.
1846138 2009-10-27 No Violations Noted
1846150 2009-10-28 No Violations Noted
1849752 2009-12-10 No Violations Noted : No activity on site. Well installation is completed. Cellar of well has water in it. There were no visible signs of gas leaking around the well head. No bubbling observed in cellar. Reserve pits have been reclaimed. The well is online.
1890373 2010-05-24 No Violations Noted
1905492 2010-07-27 No Violations Noted
1978308 2011-06-01 No Violations Noted

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2012-2 200631.24 184.0 0.0 0.0 0.0 0.0
2012-1 308729.0 181.0 0.0 0.0 0.0 0.0
2011-2 294065.95 177.0 0.0 0.0 0.0 0.0
2011-1 375102.4 181.0 0.0 0.0 0.0 0.0
2010-2 396102.0 184.0 0.0 0.0 0.0 0.0
2010-3 739777.0 226.0 0.0 0.0 0.0 0.0
2009-0 173370.0 51.0 0.0 0.0 0.0 0.0

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE
2012-2 PRODUCED FLUID 49.74 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2012-2 BASIC SEDIMENT 0.43 Bbl LANDFILL 101534 WASTE MANAGEMENT, INC - LAUREL HIGHLANDS LANDFILL JOHNSTOWN PA
2010-2 DRILLING FLUID WASTE 215.0 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119 EUREKA RESOURCES (WILLIAMSPORT WATER TREATMENT) WILLIAMSPORT PA
2010-2 DRILL CUTTINGS 105.9 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 8-437-630-00010/00 HAKES C&D LANDFILL PAINTED POST NY
2010-2 DRILL CUTTINGS 105.9 Tons LANDFILL NY # 02S17 HYLAND FACILITY ASSOCIATION ANGELICA NY
2010-2 DRILL CUTTINGS 65.1 Tons CENTRALIZED TREATMENT PLANT FOR RECYCLE 101247 KEYSTONE SANITARY LANDFILL DUNMORE PA
2010-2 DRILLING FLUID WASTE 129.4 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508 PA BRINE TRT INC - FRANKLIN PLT - VENANGO CO FRANKLIN PA
2010-2 PRODUCED FLUID 154.32 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR DRILLING OR PLUGGING PA
2010-2 DRILL CUTTINGS 18.4 Tons LANDFILL NY # 50S08 SENECA MEADOWS LANDFILL WATERLOO NY
2010-2 DRILLING FLUID WASTE 238.1 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451 SUNBURY GENERATION WASTE WATER TRMT FAC SHAMOKIN DAM PA
2010-2 DRILL CUTTINGS 858.8 Tons LANDFILL THR029 TUNNELL HILL RECLAMATION LANDFILL NEWLEXINGTON OH
2010-2 BASIC SEDIMENT 2.59 Bbl LANDFILL 101534 WASTE MANAGEMENT, INC - LAUREL HIGHLANDS LANDFILL JOHNSTOWN PA
2010-2 DRILL CUTTINGS 17.4 Tons LANDFILL 100955 WAYNE TOWNSHIP LANDFILL (CLINTON COUNTY) MC ELHATTAN PA
2011-1 PRODUCED FLUID 114.5 Bbl REUSE OTHER THAN ROAD SPREADING REUSE OF BRINE TO FRAC A WELL
2011-1 BASIC SEDIMENT 0.56 Bbl LANDFILL 101534 WASTE MANAGEMENT, INC - LAUREL HIGHLANDS LANDFILL JOHNSTOWN PA
2011-2 PRODUCED FLUID 42.27 Bbl REUSE OTHER THAN ROAD SPREADING REUSE OF BRINE TO FRAC A WELL
2012-1 PRODUCED FLUID 20.0 Bbl REUSE OTHER THAN ROAD SPREADING REUSE FOR HYDRAULIC FRACTURING
2012-1 BASIC SEDIMENT 0.23 Bbl LANDFILL 100081 WASTE MANAGEMENT, INC - SOUTHERN ALLEGHENIES DAVIDSVILLE PA